A Study on the Removal of Slagging and Fouling for an Optimal Operation of Power Utility Boilers

보일러 최적운전을 위한 슬래깅 및 파울링 제거 연구

  • Published : 2003.12.01

Abstract

An optimal soot blowing system has been developed for an optimal operation of power utility boilers by both minimization of the use of steam and the number of soot blowers worked during soot blowing. Traditionally, the soot blowing system has been operated manually by operators. However, it causes the reduction of power and thermal performance degradation because all soot blowers installed in the plant should be worked simultaneously even there are lots of tubes those are not contaminated by slagging or fouling. Heat transfer area is divided into four groups, furnace, convection area including superheater, reheater and economizer, and air preheater in the present study. The condition of cleanness of the tubes is calculated by several parameters obtained by sensors. Then, a part of soot blowers works automatically where boiler tubes are contaminated. This system has been applied in a practical power plant. Therefore, comparison has been done between this system and manual operation and the results are discussed.

Keywords

References

  1. EPRI, 1987, 'Slagging and Fouling in Pulverized- Coal-Fired Utility Boilers,' Vol I Final Report
  2. Sondreal, E. A., Tufte, P. H. and Beckering, W., 1977, 'Ash Fouling in the Combustion of Low rank Western U. S. Coals,' Combust. Sci. and Tech., Vol. 16, pp. 95-110 https://doi.org/10.1080/00102207708946797
  3. EPRI, 1988, 'Slag Monitoring for Untility Boilers,' Final Report
  4. Attig, R. C. and Duzy, A. F., 1969 'Coal Ash Deposition Studies and Application to Boiler Design,' Proceedings of the American Power Conference, Vol. 31, pp. 290-300
  5. Levert, F. E., Robinson, J. C., and Frank, R. L., 1987, 'A Slag depostion Monitor for Use in Coal-Fired Boiler,' ISA Transactions Vol. 26, No. 2, pp 51-64
  6. Simon P. Hanson and Murray F. Abbott, 1998, 'Furnace Water Wall Slag Depostion Testing in a 0.5 MW,' Prog. Energy Combust. Sci. Vol. 24, pp. 503-511 https://doi.org/10.1016/S0360-1285(98)00006-9
  7. Heil, T. C. Scanuzzo, S. A. and Nethercutt, R. M., 1981, 'Boiler Heat Transfer Model for Operator Diagonostic Information,' ASME/IEEE Power Generation Conference, pp. 1-5
  8. Baxter, L.L.et al, 1998, 'The Behavior of Inorganic Material in Biomass-Fired Power Boilers: Filed and Laboratory Experiences,' Fuel Processing Technology. 54, pp. 47-78 https://doi.org/10.1016/S0378-3820(97)00060-X
  9. Isreb, M., 1995, 'Integrated Life Synthesis for Boiler Sootblower in Fossil Power Plant,' Computer & Structure Vol. 63, No. 6 pp. 1043-1051 https://doi.org/10.1016/S0045-7949(96)00407-5