New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents

누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치

  • Published : 2003.12.01

Abstract

Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.

Keywords

References

  1. J.J.Burke, 'Application of mov gapped arrester on non effectively grounded distribution systems', IEEE Transactions on Power Delivery, Vol.6, No.2, pp.794-800, 1991 https://doi.org/10.1109/61.131137
  2. 今井康友 外, '架空地線直擊雷に對する配電用避雷器の保護效果', 日本電氣學會論文誌, B111卷, 6號, pp.619-627, 1991
  3. J.R.Ribeiro, M.E.McCallum, 'An application of metal oxide arresters in the elimination of need for closing resistors in EHV breakers', IEEE Transactions on Power Delivery, Vol.4, No.1, pp.282-291, 1989 https://doi.org/10.1109/61.19215
  4. 길경석, 한주섭, '다중뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성 변화', 대한전기학회 논문지, 제49C권, 12호, pp.685-690, 2000
  5. S.Shirakawa et al., 'Maintenance of surge arrester by portable arrester leakage current detector', IEEE Transaction on Power Delivery, Vol.3, No.3, pp.998-1003, 1988 https://doi.org/10.1109/61.193879
  6. J.Lundquist et al., 'New method for measurement of the resistive leakage currents of metal-oxide surge arrester in service', IEEE Transaction on Power Delivery, Vol.5, No.4, pp.1811-1822, 1990 https://doi.org/10.1109/61.103677
  7. 宇治田克 外, '酸化亞鉛形避雷器用漏れ電流檢出器', 三菱電機技報, Vol.55, No.3, pp.228-231, 1981
  8. 石邊信治 外, '酸化亞鉛形避雷器の劣化診斷テクニック', 電氣計算, Vol.44, No.3, pp.56-60, 1987
  9. 石崎義弘 外, '避雷器の外部診斷技術', OHM, Vol.74, No.4, pp.45-50, 1987
  10. 江藤伸夫 外, '酸化亞鉛形避雷器の漏れ電流檢出方式の提案', 日本電氣學會電力.エネルギ一部門大會, pp.850-851, 1994
  11. Gyung-Suk Kil et al., 'Electrical Characteristic Changes of ZnO Blocks by a Lightning Impulse Current and an Expert System to Diagnose Deterioration of Lightning Arresters', Proceedings of ICEE 2001, Vol.2, pp.1281-1284, 2001
  12. 길경석 외, '뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성과 피뢰기 열화진단 전문가 시스템', 대한전기학회 논문지, 제51C권, 4호, pp.152-157, 2002
  13. Gyung-Suk Kil, Ju-Seop Han, Jong-Heuk Lee, 'Influence of Harmonics in Power System Voltage on Arresters Deterioration Diagnostics', Proceedings of 2002 Joint Conference of ACED & K-J Symposium on ED and HVE, pp.151-154, 2002
  14. T.K.Gupta, 'Application of zinc oxide varistors', Journal of the American Ceramic Society, Vol.73, No.7, pp.1817-1840, 1990 https://doi.org/10.1111/j.1151-2916.1990.tb05232.x