• Title/Summary/Keyword: punctures

Search Result 39, Processing Time 0.029 seconds

Contamination of Multiple Dobe Solutions for Injection distilled water and procaine (다수회 투여용 주사용액의 오염 -증류수와 푸로카인을 중심으로-)

  • 노유자;한윤복
    • Journal of Korean Academy of Nursing
    • /
    • v.5 no.1
    • /
    • pp.87-92
    • /
    • 1975
  • This study was performed from July to December 1974 to investigate the rates of contamination of distilled water for injection and local anesthetics. 222 vials were sampled from 7 different places of St. Mary's Hospital The samples were cultured for isolation of microorganisms. The results were as follows; 1. Of 222 vials, 11 were Contaminated by 6 types: Staphylococcus epidermis, Bacillus subtilis, Mima polymorph a, Alcaligenes faecalis, Herellea vaginicala and pepto- streptococcus. 2. 5(9.1 %) of 55 vials from surgical wards, 2 (4.2 %) of 48 vials from surgical OPD, and 4 (12,l %) of 33 vials from pediatric wards were contaminated 3. Between rates of contamination of distilled water for injection and local anesthetics and the number of punctures, there was no significant relationship. (CR=1.42 P〉0.1) 4. There was no significant relationship (CR=1.02 P〉0.1) between the rates of contamination of vials and the duration of the first and the last punctures. 5. The ratios of contamination between 75% alcohol and 2% phenol used for disinfection of rubber lids of vials did not show significant difference.

  • PDF

Character Analysis that influences to Surgical Gloves Punctures (수술장갑의 천공에 영향을 미치는 특성 분석)

  • Kim, Eu Jin;Koh, Myung Suk
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.1
    • /
    • pp.99-110
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the puncture incidence of surgical gloves in an operational setting. Methods: The 277 surgical gloves were used collecting at one general hospital located in Seoul from February 1, 2011 to April 3. The data were analyzed by $x^2$ test, Fisher's exact test, and multiple logistic regression. Results: In the dental and orthopedic department, the puncture incidence were significantly higher than others. The time of wearing gloves demonstrated significant difference: The group 181-240 minutes had a significantly higher than those with under 90, 91-180, or over 240 minutes. The influencing factors were as follows. Compared to that of the 2nd assistants, the puncture incidence rates of the surgeons were 9.91 times, scrub nurses were 8.39 times higher respectively. The participants in work experience under 1 year showed a 4.58 times higher than those with over 7 years. In addition, compared to the puncture incidence rate of neurosurgery department, the 17.41 times in cardio-thoracic surgery, 13.89 times in dental surgery, 4.93 times in gynecology, and 4.97 times in orthopedics higher respectively. Conclusion: There is a need for training operational room personnels to occasionally exchange the gloves even during the procedure and to use double surgical gloves.

Spinal Arteriovenous Fistula with Progressive Paraplegia after Spinal Anaesthesia

  • Baltsavias, Gerasimos;Argyrakis, Nikolaos;Matis, Georgios K.;Mpata-Tshibemba, Stephanie
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.106-109
    • /
    • 2014
  • A case of an iatrogenic spinal arteriovenous fistula with progressive paraplegia in a young woman is reported. The fistula was eventually created after repetitive lumbar punctures performed in the process of spinal anaesthesia. Her symptoms were progressed to paraplegia over a period of 2 years. The digital subtraction angiography demonstrated a single-hole fistula, involving the anterior spinal artery and vein. The lesion was occluded by embolization with immediate improvement. The potential mechanism is discussed.

Autologous Epidural Blood Patch for the Treatment of Headache in Post-Dural Puncture -Report of 37 cases- (요부경막천자후 발생된 두통치료 -자가혈액봉합 37예-)

  • Lee, Sung-Keun;Kim, Tae-Jung;Kim, Yong-Ik;Kim, Il-Ho;Song, Hoo-Bin;Kim, Soon-Im;Park, Wook;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.2 no.1
    • /
    • pp.89-93
    • /
    • 1989
  • We performed the autologous epidural blood patch (AEBP) for the relief of headache and other related symptoms following dural punctures of the lumbar region during 8 years from 1981 to 1988. The total of 37 patients with the patching consisted of 9 cases in 3007 of spinal anesthesia, 12 accidental dural punctures in 4283 cases of lumbar epidural anesthesia, 12 cases in 4747 of epidural analgesia for back pain control, 3 cases of myelography and a case of diagnostic lumbar puncture. The headaches were relieved completely in 35 cases following the first AEBP and the remaining two were also relieved following the second AEBP. We think that the AEBP for postdural-puncture headache is the treatment of choice.

  • PDF

New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents (누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치)

  • 길경석;한주섭;송재영;조한구;한문섭
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.562-567
    • /
    • 2003
  • Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.

Biomechanical Properties of the Cranial Dura Mater with Puncture Defects : An In Vitro Study

  • Aydin, Hasan Emre;Kizmazoglu, Ceren;Kaya, Ismail;Husemoglu, Bugra;Sozer, Gulden;Havitcioglu, Hasan;Arslantas, Ali
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.382-388
    • /
    • 2019
  • Objective : The primary aim of this investigation was to explore the nature of dura mater biomechanics following the introduction of puncture defect(s). Methods : Twenty-eight dura mater specimens were collected during autopsy from the department of forensic medicine of the authors' institution. Specimens were divided randomly into one of four groups : group I (cranial dura mater; n=7), group II (cranial dura mater with one puncture defect; n=7); group III (cranial dura mater with two puncture defects; n=7), and group IV (cranial dura mater with three puncture defects; n=7). Results : The mean${\pm}$standard deviation tensile strengths of the dura mater were $8.35{\pm}3.16$, $8.22{\pm}3.32$, $7.13{\pm}1.77$, and $6.94{\pm}1.93MPa$ for groups I, II, III, and IV, respectively. There was no statistical difference between all groups. A single, two or more punctures of the dura mater using a 20-gauge Quincke needle did not affect cranial dura tensile strength. Conclusion : This biomechanical study may contribute to the future development of artificial dura mater substitutes and medical needles that have a lower negative impact on the biomechanical properties of dura mater.

The Genus Philanthus (Hymenoptera: Sphecidae: Philanthinae) in Korea

  • Kim, Jeong-Kyu;Kim, Dong-Eon;Lee, Heung-Sik
    • Animal Systematics, Evolution and Diversity
    • /
    • v.36 no.1
    • /
    • pp.41-45
    • /
    • 2020
  • The genus Philanthus Fabricius, 1790 in Korea are reviewed, and two species, Philanthus triangulum and P. coronata, are treated. The former is new to Korea. This species is easily separated from congeners by dense punctures in propodral enclosure and tri-forked marking in lower face. DNA barcoding test is supportive in our identification as well as conspecitficity of Korean materials showing variation in size and coloration. The observed data on flower associations of this species specified with domestic localites and date are separately provided. The current status of Philanthus coronatus that has been the only representative of the genus but forgotten for a lengthy time in Korea is discussed.

Spontaneous Resolution of Nontraumatic Acute Spinal Subdural Hematoma

  • Yang, Na-Rae;Kim, Sang-Jin;Cho, Yong-Jae;Cho, Do-Sang
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.268-270
    • /
    • 2011
  • Spinal subdural hematoma (SSDH) is an extremely uncommon condition. Causative factors include trauma, anticoagulant drug administration, hemostatic disorders, and vascular disorders such as arteriovenous malformations and lumbar punctures. Of SSDH cases, those that do not have any traumatic event can be considered cases of nontraumatic acute spinal subdural hematoma, which is known to have diverse clinical progress. Treatment typically consists of surgical decompression and cases in which the condition is relieved with conservative treatment are rarely reported. We report two nontraumatic acute spinal subdural hematoma patients who were successfully treated without surgery.

Segmental Artery Injury Following Percutaneous Vertebroplasty Using Extrapedicular Approach

  • Heo, Dong-Hwa;Cho, Yong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.131-133
    • /
    • 2011
  • We performed a percutaneous vertebroplasty at the compressed L2 vertebral body of a 73-year-old female using a left-sided unilateral extrapedicular approach. She complained severe radiating pain and a tingling sensation in her left leg two hours after the vertebroplasty. Spinal computed tomographic scan showed a large retroperitoneal hematoma, and a subsequent spinal angiography revealed a left L2 segmental artery injury. Bleeding was successfully controlled by endovascular embolization. Recently, extrapedicular approaches have been attempted, allowing for the avoidance of facet and pedicle injury with only a unilateral approach. With this approach, however, the needle punctures the vertebral body directly. Therefore, this procedure carries the potential risk of a spinal segmental artery.

Continuous Stellate Ganglion Block for Raynaud'S Disease -A case report- (Catheter를 이용한 지속적 성상신경절 차단 경험 -증례 보고-)

  • Lee, Sang-Ryull
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.278-280
    • /
    • 1997
  • Stellate ganglion block has been used to treat diseases such as peripheral vascular disease, sympathetic dystrophy, and various pain syndromes involving the head or arm. Raynaud's disease is a syndrome manifested by attacks of pallor, cyanosis, numbness and pain of the digits in response to cold or emotional change. I report one case who was given Stellate ganglion block using 18G teflon Catheter(4.5 cm in length) for Raynaud's disease. Continuous stellate ganglion block is more convinient to inpatient than repeated needle punctures and may reduce major complications and more useful to patient who needs continuous sympathetic block about one week duration.

  • PDF