Elastic force degradation of synthetic elastomeric chain

체인형 합성고무탄성재의 탄성력 감쇄

  • HEO, Chang-Hyuck (Department of Orthodontics, College of Dentistry, Kyungpook National University) ;
  • SUNG, Jae-Hyun (Department of Orthodontics, College of Dentistry, Kyungpook National University) ;
  • KWON, Oh-Won (Department of Orthodontics, College of Dentistry, Kyungpook National University) ;
  • KYUNG, Hee-Moon (Department of Orthodontics, College of Dentistry, Kyungpook National University)
  • 허창혁 (경북대학교 치과대학 교정학교실) ;
  • 성재현 (경북대학교 치과대학 교정학교실) ;
  • 권오원 (경북대학교 치과대학 교정학교실) ;
  • 경희문 (경북대학교 치과대학 교정학교실)
  • Published : 2003.10.01

Abstract

The purpose of this study was to evaluate the force degradation rate of synthetic elastomeric chains during space closing phase of orthodontic treatment. Two kinds of synthetic elastomeric chains(RMO, 3M) were selected which were commonly used In clinics. All of the samples were extended and tested for 4 weeks under the simulated intraoral condition. The results can be summarized as follows : 1. Time related residual force showed typical logarithm function. Residual force after 4 weeks was $41.2\~64.6\%$ of original force, and difference between two kinds of elastomeric chain existed. 2. Elastic force decreased greatly during first 10 minutes, so $20\~25\%$ of original force disappeared. After that, this decreasing tendency was diminished significantly, average rate of elastic force after 1 week to 4 weeks were $1.5\%$ demonstrating rather constant force. 3. Even though the same brand of elastomeric chiain was used, as extension rate of elastomeric chain increased, force degradation rate increased by decreasing of residual force.

본 연구는 체인형 합성고무탄성재의 시간에 따른 탄성력 감쇄의 양상을 평가하여, 이들 재료의 임상적용시 적절한 교정력의 적용을 위해 참고가 될 만한 기준을 구해보려는 목적으로 시행되었다. 공간폐쇄시 사용되는 체인형 합성고무탄성재의 탄성감쇄정도를 알아보기 위하여, 임상에 널리 사용되는 두 가지의 체인형 합성고무탄성재를 구강내 상태와 유사한 조건하에서 4주간 신장시켜 관찰한 결과 다음과 같이 요약할 수 있었다. 1. 시간에 따른 탄성력 감쇄양상은 전형적인 log함수의 형태를 보이며, 4주후 잔존탄성력은 원래의 $41.2\~64.6\%$이며 제품에 따라 차이가 있었다. 2. 신장후 초기 10분 동안 탄성력의 급격한 감소를 보여서, 초기힘의 $20\~25\%$를 상실하였으며, 이후 감소량이 줄어들어 1주이후부터 4주까지의 평균감소량은 $1.5\%$정도로 거의 일정한 힘의 크기를 보여주었다. 3. 동일한 재료를 사용하더라도, 탄성재의 신장량이 증가할수록 잔존탄성력이 감소하여 탄성감쇄율이 증가하였다

Keywords

References

  1. Proffit WR. Contemporary orthodontics. 3rd ed, Missouri : Mosby, 2000 : 333, 345
  2. 김 명웅. 고무工業化學, 서울 : 선웅, 2000 : 12-3
  3. Case CS. Original use and misuse of the intermaxillary force, and its relations to occipital and other anchorage forces in orthodontia. Dental Cosmos 1904 : 345-62
  4. Angle EH. Treatment of malocclusion of the teeth. 7th ed, Philadelphia : SS White, 1907: 257
  5. Baty DL, Volz JE, von Fraunhofer JA. Synthetic elastomeric chains: A literature review. Am J Orthod Dentofac Orthop 1994 : 105: 536-42
  6. 김 홍재. 폴리우레탄 樹脂, 서울 : 대광, 1995
  7. Kanchana P, Godfrey K. Calibration of force extension and force degradation characteristics of orthodontic latex elastics. Am J Orthod Dentofac Orthop 2000 : 118 : 280-7
  8. Kovatch JS, Lautenschlager EP, Apfel DA, Keller JC. Load-extension-time behavior of orthodontic Alastiks. J Dent Res 1976 : 55 : 783-6
  9. Brooks DG, Hershey HG. Effects of heat and time on stretched plastic orthodontic modules. lADR Abstracts 1976 : 363
  10. Brantley WA, Salander S, Myers CL, Winders RV. Effects of prestretching on force degradation characteristics of plastic modules. Angle Orthod 1979 : 49 : 37-43
  11. Young J, Sandrik JL. The influence of preloading on stress relaxation of orthodontic elastic polymers. Angle Orthod 1979 : 49 : 104-9
  12. Von Fraunhofer JA, Coffelt MT, Orbell GM. The effects of artificial saliva and topical fluoride treatments on the degradation of the elastic properties of orthodontic chains. Angle Orthod 1992 : 62 : 265-74
  13. Ash JL, Nikolai RJ. Relaxation of orthodontic elastomeric chains and modules and in vitro and in vivo. J Dent Res 1978 : 57 : 685-90
  14. Lu TC, Wang WN, Tamg TH, Chen JW. Force decay of elastomeric chain:A serial study. Part II. Am J Orthod Dentofacial Orthop 1993 : 104: 373-7 https://doi.org/10.1016/S0889-5406(05)81336-8
  15. Baty DL, Volz JE, von Fraunhofer JA. Force delivery properties of colored elastomeric modules. Am J Orthod Dentofac Orthop 1994 : 106 : 40-6
  16. Josell SD, Leiss JB, Rekow ED. Force degradation in elastomeric chain. Semi Orthod 1997 : 3 : 189-97
  17. Ferriter JP, Meyers CE, Lorton L.. The effect of hydrogen ion concentration on the force-degradation rate of orthodontic polyurethane chain elastics. Am J Orthod Dentofac Orthop 1990 : 98 : 404-10
  18. De Genova DC, Mcinnes-Ledoux P, Weinberg R, Shaye R. Force degradation of orthodontic elastomeric chains-A product comparison study. Am J Orthod 1985 : 87 : 377-84 https://doi.org/10.1016/0002-9416(85)90197-6
  19. Andreasen GF, Bishara S. Comparison of Alastik chains with elastics involved with intra-arch molar to molar force. Angle Orthod 1970 : 40 : 151-8
  20. Huget EF, Patrick KS. Nunez LJ. Observations on the elastic behavior of a synthetic orthodontic elastomer. J Dent Res 1990 : 69 : 496-501
  21. Eliades T, William A Brantley. Orthodontic materials, New York: Thieme, 2001 : 173-87
  22. Bishara SE, Andreasen GF. A comparison of time related forces between plastic Alastiks and latex elastics. Angle Orthod 1970 : 40 : 319-28
  23. Hershey HG, Reynolds WG. The plastic module as an orthodontic tooth-moving mechanism. Am J Orthod 1975 : 67 : 554-62
  24. Wong AK. Orthodontic elastic materials. Angle Orthod 1976 : 46 : 196-205
  25. Killiany DM, Duplessis J. Relaxation of elastomeric chains. J Clin Orthod 1985 : 19 : 592-3
  26. Sonis AL. Comparison of NiTi coil springs vs. Elastics in canine retraction. J Clin Orthod 1994 : 28 : 293-95
  27. Nattrass C, Ireland AJ, Sherriff M. An investigation into the placement of force delivery systems and the initial forces applied by clinicians during space closure. Br J Orthod 1997 : 24 : 127-31
  28. Samuels RH, Rudge SJ, Mair LH. A clinical study of space closure with nickel-titanium closed coil springs and an elastic module. Am J Orthod Dentofac Orthop 1998 : 114: 73-9
  29. Rock WP, Wilson HJ, Fisher SE. A laboratory investigation of orthodontic elastomeric chains. Br J Orthod 1985 : 12 : 202-7
  30. Williams JW, von Fraunhofer JA. Degradation of the elastic properties of elastomeric chains[Thesis.], Louisville, Kentucky : University of Louisville, 1989.
  31. Jeffries CL, von Fraunhofer J. The effects of 2% alkaline gluteraldehyde solution on the elastic properties of elastomeric chain. Angle Orthod 1991 : 61 : 25-30
  32. Storie DJ, Regennitter F, von Fraunhofer JA. Characteristics of a fluoride -releasing elastomeric chain. Angle Orthod 1994 : 64 : 199-210
  33. 김대식, 김영준, 최재훈, 한종훈. 한국성인정상교합자의 치아크기와 비율에 관한 연구, 대치교정지 2001 : 31 : 505-15
  34. Schwarz, A. M. Tissue changes incidental to orthodontic tooth movement. Int J Orthod 1932 : 18 : 331.
  35. Storey E, Smith R. Force in orthodontics and its relation to tooth movement. Austr J Dent 1952 : 56 : 11-8
  36. Hixon E, Atikian H, Callow G, McDonald H, Tracy R. Optimal force, differential force, and anchorage. Am J Orthod Dentofac Orthop 1969 : 55 : 437-57
  37. Boester CH, Johnston LE. A clinical investigation of the concepts of differential and optimal force in canine retraction. Am J Orthod Dentofac Orthop 1974 : 44 : 113-9
  38. Ricketts, R. M., Bench, R., Gugino, C., et al. Bioprogressive therapy, Denver: Rocky Mountain Orthodontics, 1977