DOI QR코드

DOI QR Code

밸브 후단 피팅에 따른 밸브 용량계수의 영향 평가

Evaluation of the Effect on the Valve Flow Coefficient by Attached Fitting

  • 발행 : 2003.12.01

초록

This study was undertaken to verify the effect of flow coefficient when a globe control valve was attached by different type of fitting. The valve flow coefficient is usually determined by measuring the flow rate and the pressure drop with the connection of straight pipe through the valve. The effect of different fitting that is mounted on the downstream of the valve is studied. Four types of fittings and three distances between the valve and a downstream fitting are compared parametrically to investigate the effect on the flow coefficient of it. Measured flow coefficient and numerically predicted value by using computational fluid dynamics were compared in detail. It is concluded that the flow coefficient is reduced if the fitting is attached after a valve, but the effect of different type of fitting is not crucial.

키워드

참고문헌

  1. IEC 60534-2-3, Industrial-process control valves: Flow capacity-Test procedures, Second edition, 1997-12
  2. KS B 2101, 밸브의 용량계수 시험 방법, 1999
  3. Davis, J. A, and Stewart, M B., 2002, 'Predicting Globe Control Valve Performance-Part I: CFD Modeling,' ASME J. Fluids Eng., Vol. 118, pp. 562-568 https://doi.org/10.1115/1.2817795
  4. Davis, J. A, and Stewart, M B., 2002, 'Predicting Globe Control Valve Performance-Part II: Experimental Validation,' ASME J. Fluids Eng., Vol. 124, pp. 778-783 https://doi.org/10.1115/1.1490126
  5. Lee, J. J., and Wellford, L. C., 1997, 'Transient Fluid-Structure Interaction in a Control Valve,' ASME J. Fluids Eng., Vol. 119, pp.354-359 https://doi.org/10.1115/1.2819141
  6. 윤준용외 5인 공역, 1999, 유체역학, 淸文閣
  7. Hinze, J. O., 1975, Turbulence, McGraw-Hill, Inc.
  8. FLUENT, 1998, User's Guide, Fluent Inc.