• 제목/요약/키워드: Valve flow coefficient

검색결과 190건 처리시간 0.028초

밸브 후단 피팅에 따른 밸브 용량계수의 영향 평가 (Evaluation of the Effect on the Valve Flow Coefficient by Attached Fitting)

  • 강승규;이원식;윤준용;민경화
    • 한국유체기계학회 논문집
    • /
    • 제6권4호
    • /
    • pp.29-37
    • /
    • 2003
  • This study was undertaken to verify the effect of flow coefficient when a globe control valve was attached by different type of fitting. The valve flow coefficient is usually determined by measuring the flow rate and the pressure drop with the connection of straight pipe through the valve. The effect of different fitting that is mounted on the downstream of the valve is studied. Four types of fittings and three distances between the valve and a downstream fitting are compared parametrically to investigate the effect on the flow coefficient of it. Measured flow coefficient and numerically predicted value by using computational fluid dynamics were compared in detail. It is concluded that the flow coefficient is reduced if the fitting is attached after a valve, but the effect of different type of fitting is not crucial.

유동 강화형 밸브의 형상에 따른 정상 유동 특성 (Steady Flow Characteristics of Flow-Intensifying Valve Configurations)

  • 최수진;류기현;전충환;장영준
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.166-174
    • /
    • 1999
  • The flow characteristics of 2-valve and 4-valve cylinder heads with various blocked-valve were experimentally investigated in a steady flow rig. Effects of the blocked-valve configurations on flow coefficient, swirl and tumble intensity are studied. Compared to the conventional valve, the blocked valve in both cylinder heads have the much lower flow coefficient and the much higher intensity of swirl and tumble. Under the same size of blockage, the value of flow coefficient and swirl(or tumble) intensity were varied according to the position of blockage. Throughout these steady flow test the optimized positions of blockage in both cylinder heads were determined.

흡기3밸브 실린더 헤드의 흡입 정상유동 특성에 관한 연구 (A Study on the Steady Intake Flow Characteristics of the Intake 3-Valve Cylinder Head)

  • 정재우;이기형;김우태
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.880-885
    • /
    • 2000
  • Flow patterns and steady flow characteristics of an intake 3valve cylinder head are not obviously declared. Thus, in the study, the characteristics and limitation of intake flow coefficient which applied to multi intake valve engine are introduced. The flow coefficient and tumble characteristics are investigated by means of the steady flow test and flow visualization method. As the results, it is found that the intake flow rate is dominated by effective valve open area. In addition, this paper shows that the mass flow rate of intake 3valve engine is greater than that of intake 2valve engine and tumble flow of intake 3valve engine is superior to that of intake 2valve engine.

밸브 형식별 유량제어범위 결정에 관한 연구 (Study of Flow Control Range according to Valve Type)

  • 박종호;박한영
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.39-47
    • /
    • 2011
  • Flow control range of valve, which is installed on pipeline, varies according to valve type, pipe diameter, pipe length, roughness, and elevation difference of both ends of pipeline. A lot of computation efforts and knowledge are needed to estimate flow control range of valve, considering above many parameters. The table of flow control range of each valve type is presented for convenience of pipeline design engineers who must make decision of valve size and type in this study. Also the reason that butterfly valve is recommended for flow control, and gate valve is forbidden is presented via quantification and figures in this study.

냉열발전을 위한 극저온 체크밸브의 유동해석 (Flow Analysis of Cryogenic Check Valve for LNG)

  • 문정현
    • 동력기계공학회지
    • /
    • 제20권1호
    • /
    • pp.5-10
    • /
    • 2016
  • Swing check valve is opened when the flow direction is forward, when the flow is reversed, the valve is automatically closed by back pressure. In this study, the internal flow field analysis of the valve was conducted by Fluent. The working fluid used in the study, using liquefied methane $-165^{\circ}C$ (CH4) and velocity field, pressure field, pressure drop coefficient were simulated by varying separately the opening divergence into four intervals from 0 to 100%. The approximate research result are as follow : When the opening divergence is smaller, it appears high pressure on the upstream side, this value is relaxed when the opening divergence is large. Flow rate coefficient of the valve shows a larger value as the degree of opening becomes larger, confirming that the check valve used in the study is in the effective flow rate counting range.

제어밸브 유량특성에 레이놀즈 수가 미치는 영향 (Effect of Reynolds Number on the Flow Characteristics of a Control Valve)

  • 정태규
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.995-999
    • /
    • 2017
  • 제어밸브의 유량계수에 영향을 미치는 인자들을 파악하고 그 영향을 분석하였다. 제어밸브의 유량계수는 레이놀즈 수, 연결 배관의 형상과 표면 조도 등에 영향을 받는다. 따라서 유량계수를 상수로 취급할 수 없다. 그러므로 로켓엔진과 같이 정확한 유량계수를 요구하는 시스템에서 사용할 목적으로 제어밸브의 유량계수를 측정할 때는 실제 사용 환경과 유사한 레이놀즈 수 영역에서, 동일한 조도 및 형상을 가지는 입출구 배관을 사용하여 측정해야 한다.

  • PDF

극저온 버터플라이 밸브의 유속에 따른 캐비테이션 발생 예측 (Prediction of Cavitation Occurrence in a Cryogenic Butterfly Valve by Flow Velocity)

  • 김성동;김범석;최영도;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.923-930
    • /
    • 2008
  • The butterfly valve is widely used in the industrial field as an on-off or a flow control valve. When the butterfly valve is used as a flow control valve. cavitation sometimes occurs in the range of high flow rate because of the small valve opening. Therefore. the pressure loss and the cavitation characteristics are investigated by use of a commercial CFD code. The results show that the possibility of cavitation occurrence in the cryogenic butterfly valve is very high in the case of valve opening angle below 10 degree and incident velocity over 6m/s. By increasing the inlet velocity at 10 degree of valve opening angle. the value of loss coefficient increased. However. by increasing the inlet velocity at 50 degree of valve opening angle. the value of loss coefficient decreased.

플랜트 및 선박의 액체용 우량제어밸브 설계에 관한 연구(II) (A Study on the Design of Liquid Flow Control Valves for the Pants and Ships(II))

  • 최순호;배윤영;김태한;한기남;주경인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권2호
    • /
    • pp.1-9
    • /
    • 1995
  • The processing paper has devoted to the theory of the flow equations, the basic derivative procedure, the meaning of a valve flow coefficient $C_v$, the valve Reynolds R$R_{ev}$ and its application for liquid control valves, which applicable under the condition of a non-critical flow and the case of piping geometry factor $F_p$=1.0. However there is no information on the effects of fittings, a critical flow and the flow resistance coefficient of a valve equivalent to that of pipe which is conveniently used in the piping design. Since the piping systems of plants or ships generally contain various fittings such as expanders and reducers due to different size between pipes and valves and there may occur a critical flow, that a mass flowrate is maintained to be constant, due to the pressure drop in a piping when a liquid is initially maintainder ar a saturated temperature or at nearby corresponding to upstream pressure, system designer should have a knowledge of the effect to flow due to fittings and the critical flow phenomenon of a liquid. This study is performed to inform system designers with the critical flow phenomenon of a liquid, a valve resistance coefficient, a valve geometry factor and their applications.

  • PDF

화력발전소용 1인치 볼 밸브 유량계수 Cv에 관한 유동해석 및 실험에 관한 연구 (Experiment and Flow Analysis of the Flow Coefficient Cv of a 1 inch Ball Valve for a Thermal Power Plant)

  • 강창원;이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제18권3호
    • /
    • pp.109-115
    • /
    • 2019
  • The purpose of this study was to analyze and test the flow rate of a 1-inch ball valve used in a thermal power plant. To identify the flow-rate characteristics, numerical analysis was conducted and an experimental apparatus of the valve flow rate coefficient was used to compare the flow coefficient Cv values. To determine the internal pressure distribution, the sites of opening ball valves and flow fields were investigated. In particular, a smaller the valve opening resulted in a more complicated the flow field of the ball. The valve flow characteristic test showed that the Cv value and flow rate increased with increasing valve-opening rate and the secondary function was performed. The pressure drop increased as the valve opening rate decreased. In addition, the experimental results for the flow analysis are similar to the numerical analysis results.

Cone Type 밸브 내부유동 수치해석에 관한 연구 (A Study on the Numerical Analysis of Internal Flow in a Cone Type Valve)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.199-207
    • /
    • 2020
  • These days, many different types of valves are developed in the industrial area according to their use purpose. Multiple kinds of valves are installed to control a flow and pressure of the pipe conveying fluid. Valves serve as critical roles in land plants such as power plants. The performance of equipment varies depending on valve characteristics. In this study, the internal flow analysis on Cone-type valve is conducted to analyze flow field and secure a value of the flow coefficient Cv. According to the internal flow analysis, when the flow distribution of the middle cross-section of valve was open 100%, flow field was relatively and smoothly taken out. If it was open 50%, flow recirculation region increased and a little complex flow field occurred. Unlike ball valve or butterfly valve, this valve had flow recirculation in its outlet depending on a valve opening amount. Therefore, it was found that there was no flow recirculation in the outlet of Cone-type valve.