• Title/Summary/Keyword: Medical Instruments

Search Result 527, Processing Time 0.028 seconds

A Review of the Pain and Function Assessment Instruments for Shoulder Disease Patients in Korean Medicine Clinical Studies Published in South Korea (국내 한의임상연구에서의 어깨질환 환자의 통증 및 기능측정도구 사용에 대한 현황분석)

  • Lee, Geon-Yeong;Jo, Hee-Geun;Seol, Jae-Uk;Kim, Shin-Ae
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.1
    • /
    • pp.33-51
    • /
    • 2018
  • Objectives The purpose of this study is to analyze the current status of measurement instruments used to evaluate pain and function for shoulder disease patients in Korean Medicine clinical studies published in South Korea. Methods 5 Korean online databases from January 2007 to July 2017 were used to source articles for the review. Data of pain and function assessment instruments, measurement methods, time point and frequency for shoulder assessment were extracted. And it was analyzed by investigating the frequency of use for each item. Results A total of 78 studies met the selection criteria. There were many studies with no description for pain assessment instruments or inconsistent measurement methods. In the function assessment, the frequency of use was low and there were a lot of use of instruments with low validity and reliability. Conclusions To develop the objectivity of clinical research, further clinical studies, active use of measurement instruments, and standardization of measurement methods are needed.

Health-related Quality of Life in Women with Breast Cancer: a Literature-based Review of Psychometric Properties of Breast Cancer-specific Measures

  • Niu, Hui-Yan;Niu, Chun-Ying;Wang, Jia-He;Zhang, Yi;He, Ping
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3533-3536
    • /
    • 2014
  • Background: Breast cancer is one of the most common cancers in women in the world. Health-related quality of life (HRQL) at treatment endpoint in cancer clinical trials is widely considered to be increasingly important. The aim of this review was to provide a literature-based assessment of the validity, reliability and responsiveness of breast cancer-specific HRQL instruments in women breast cancer patients. Materials and Methods: The databases consulted were Medline, PubMed, and Embase. The inclusion criteria required studies to: (1) involve use of HRQL measures; (2) cover women with breast cancer under standard treatment (surgery, radiation therapy, chemotherapy, hormone therapy, and targeted therapy); (3) involve the validity, reliability, or responsiveness of HRQL; (4) deal with validation of breast cancer-specific HRQL instruments. Results: A total of 16 studies were identified through the literature search that met the 4 inclusion criteria. Some seven instruments were assessed among these 16 studies: EORTC QLQ-BR23, FACT-B, FACT-ES, HFRDIS, LSQ-32, QLICP-BR, and SLDS-BC. EORTC QLQ-BR23, FACT-B, LSQ-32, QLICP-BR, and SLDS-BC are more general breast cancer-specific HRQL instruments. FACT-EB is the endocrine subscale combined with FACT-B in order to measure the side effects and putative benefits of hormonal treatment administered in breast cancer patients. HFRDIS is the HRQL measure focusing on hot flash concerns. Conclusions: This paper provides an overall understanding on the currently available breast cancer-specific HRQL instruments in women breast cancer patients.

Characteristics of EMG Median Frequency and Torque During Isometric Back Extension Exercises (등척성 요추 신전운동 시 중앙주파수와 토크의 특성)

  • Kang, S. J.;Park, S. J.;Jang, K.;Park, K. H.;Kwon, O. Y.;Kim, Y. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • Localized muscle fatigue can be identified by a downward shift of the EMG frequency typically represented by a fall in the median frequency The Present experimental study was Performed to investigate the time change of the median frequency and the muscle torque during maximal isometric back extension exercises at different exercise angles (0$^{\circ}$, 12$^{\circ}$, 36$^{\circ}$and 72$^{\circ}$) Twenty heath subjects (mean age : 24.35 $\pm$ 2.70) were Participated in this study Median frequency was extracted from EMG signals by employing the fast Fourier transform. Initial median frequency and the slope of median frequency was not significantly correlated with the muscle torque. Pearson's Product moment correlation was used to quantify the relationship between slopes of median frequency and torque. The results may suggest that the exorcise angle during maximal isometric back extension exercises does not affect the slopes of the median frequency and torque, and y-intercept of the median frequency among exercise angles There was no significant correlation between slopes of median frequency and torque. But there was a moderate correlation between median frequency and torque at each exercise angle. In conclusion, the exercise angle during maximal isometric back extension exercise is not a direct effect on slopes of median frequency and torque. But results showed that the shift of median frequency and torque shift were highly correlated in all subjects.

Comparative Study on Cupping Apparatuses for Medical Use by Mechanical Stability and Functional Test (수동식 부항기의 기계적 안정성과 성능의 실험적 비교연구)

  • Soh, Mun-Gie;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.2
    • /
    • pp.157-167
    • /
    • 2008
  • Objectives : It is sure that standardization of medical instruments is very important and necessary. Cupping therapy is one of the traditional oriental medical method, and it is necessary to set up a standard of cupping therapy and instruments. Methods : We select 3 major cupping instrument makers according to a questionnaire survey of 2001 oriental medical doctors. Dae Gun is A maker, Han Sol is B maker, Dong Bang is C maker. And with these air pumps we make experiments on stability by an inner impact test and a falling test. With these cups we check stability by an inner impact test and a disinfection test. And to know function of these instruments we test a negative pressure and maintain attached cups until 5 to 10minutes. Results : All results of experiments(impacted test, disinfection test, falling test) on stability of cups and air pumps are suitable for medical instrument. And the efficiency of 3 major makers shows various results. Negative pressure of B group is the highest, C group is the second, A group is the lowest. Pressure maintenance test shows A and C group is comparatively up to the experimental standard(<10%), B group is comparatively below the experimental standard(<10%). Conclusions : Results show stability of cups and air pumps is suitable for medical instruments. And negative pressure of cupping and maintenance of pressure show various results. So it is necessary to set up a standard negative pressure of cupping and maintenance of pressure.

Early Clinical Outcomes of Thoracoscopic Major Pulmonary Resection and Thymectomy Using Novel Articulating Endoscopic Forceps

  • Sangil Yun;You Jung Ok;Se Jin Oh;Jae-Sung Choi;Hyeon Jong Moon;Yong Won Seong
    • Journal of Chest Surgery
    • /
    • v.57 no.4
    • /
    • pp.329-338
    • /
    • 2024
  • Background: Video-assisted thoracoscopic surgery (VATS) is recognized as a safe and effective treatment modality for early-stage lung cancer and anterior mediastinal masses. Recently, novel articulating instruments have been developed and introduced to endoscopic surgery. Here, we share our early experiences with VATS major pulmonary resection and thymectomy performed using ArtiSential articulating instruments. Methods: At the Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 500 patients underwent VATS pulmonary resection between July 2020 and April 2023, while 43 patients underwent VATS thymectomy between January 2020 and April 2023. After exclusion, 224 patients were enrolled for VATS major pulmonary resection, and 38 were enrolled for VATS thymectomy. ArtiSential forceps were utilized in 35 of the 224 patients undergoing pulmonary resection and in 12 of the 38 individuals undergoing thymectomy. Early clinical outcomes were retrospectively analyzed. Results: No significant differences were observed in sex, age, surgical approach, operation time, histological diagnosis, or additional procedures between the patients who underwent surgery using novel articulating instruments and the group treated with conventional endoscopic instruments for both VATS major pulmonary resection and thymectomy. However, the use of the novel articulating endoscopic forceps was associated with a significantly larger number of dissected lymph nodes (p=0.028) and lower estimated blood loss (p=0.009) in VATS major pulmonary resection. Conclusion: Major pulmonary resection and thymectomy via VATS using ArtiSential forceps were found to be safe and effective, with early clinical outcomes comparable to established methods. Further research into long-term clinical outcomes and cost-effectiveness is warranted.

Software Platform for Stability Assure of Sensor Network in u-Health Environment (유헬스 환경에서 센서네트워크의 안정성 보장을 위한 소프트웨어 플랫폼)

  • Jung, Min Woo;Cho, Jeonghun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.5
    • /
    • pp.219-226
    • /
    • 2012
  • The rises of the life index quality together with the medical technology improvement lead to a longer life expectancy. Then a better health care program, especially for elderly, is needed. The common health problems facing those senior citizens are changed from acute diseases to chronic diseases, such as diabetes, hypertension. Then u-Health takes center stage in medical industry. Although u- Health medical device manufacturers have been improving their instruments, these instruments still rely on proprietary technologies without fixed platform. Even if the interface has been provided by the manufacturer, there is no widely-accepted uniform data model to access data of various u-Health devices. IEEE 11073 is a standard attempting to unify the interfaces of all medical devices. In this paper we have proposed a conversion software platform that assures interoperability among medical devices for ubiquitous sensor network. This module uses in order to develop a standard platform of medical system.

Intra-luminal Thrombus Reduces Stress in the Aneurysm Wall: Fluid-Structure Interaction in Pulsatile Flow

  • Kim S. Y.;Kim Y. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.147-149
    • /
    • 2003
  • Using computational fluid dynamics with the fluid-structure interaction, structural effects of intra-luminal thrombus were determined in thrombosed axisymmetric abdominal aorta aneurysm (AAA) models under pulsatile flow. Four different models, varying dilatations of the aneurysm and Young's moduli of intra-luminal thrombus, were defmed. Compared with unthrombosed AAA models, both von Mises stress and radial displacements in the aneurysm wall significantly decreased. Stiffer intra-luminal thrombus reduced von Mises stress in the aneUtysm wall. The present study supported that intra-luminal thrombus might reduce wall stress in the aneurysm.

  • PDF