Abstract

Recently, the construction of tunnels longer than one kilometer has increased rapidly. Considering characteristic of limiting structure of longer tunnel, if fires inside tunnel broke out because of vehicle incidents, the catastroph would have high possibility to take place due to toxic smoke and heat of fire. In case of highway tunnel, safety facilities which can cope with tunnel fire are installed in the tunnel but according to rapid increase of heavy good traffic, dangerous goods and enlargement of tunnel magnitude, the research has to carry out about heat fluxes and smoke behaviour during tunnel fire. Therefore, through full-sized fire experiment the paper analyzed temperature distribution, wind velocity, smoke behaviour during tunnel fire.

최근들어 1km이상의 장대터널건설이 급증하는 추세이고 이로 인해 터널내 화재가 발생하면 터널내부는 외부와의 통로가 한정되고 고립된 공간이므로 화재로부터 발생되는 연기와 열로 대형인명사고가 발생 가능성이 높아지고 있다. 그러므로 고속도로 터널의 경우, 터널화재에 대비한 방재시스템을 구축하고 있지만 터널의 장대화, 화물운송차량의 대형화, 운반물류의 다양화에 따라 가연물의 규모, 터널내 기류등 다양화된 제반조건을 세부적으로 고려한 화염확산 형태 및 연기유동 메카니즘에 대한 연구가 필요하다. 따라서 본 연구에서는 고속도로 터널 실물화재실험을 수행하여 화재발생시 터널내부의 온도분포, 풍속, 연기거동 특성을 분석하였다.