Abstract
The EV ROM, a joint reservoir operation model for flood control that accounts for the downstream flow condition, has been introduced in the preceding article (Shin et al, 2000). A joint reservoir operation model computer program for the Geum river basin, developed by FORTRAN Power Station 4.0 using the EV ROM, is hereby presented. Three case studies of flood control by joint operation of the Yongdam and Daechung Multipurpose Dams in the Geum river basin revealed that the performance of the EV ROM was superior to the existing Rigid ROM and Technical ROM. This is because the EV ROM can account for the downstream flow condition as well as the upstream inflow and the reservoir water level. In order to apply for various floods events in the future, consistent improvement of the developed EV ROM and efforts for more accurate rainfall prediction are required.
본 연구의 제Ⅰ보 (신용노 등, 2000)에서는 댐의 제약조건과 댐 상·하류의 유출상황을 고려하여 홍수기 댐을 운영 할 수 있는 모의기법 모형인 EV ROM을 개발하였고, 본 보에서는 제Ⅰ보에서 개발된 EV ROM을 FORTRAN Power Station 4.0에 의해 금강수계 댐군을 연계운영 할 수 있는 전산프로그램을 개발하였다. 개발된 프로그램을 사용하여 금강수계에서 발생한 3개 홍수사상에 적용해 본 결과 기존의 Rigid ROM이나 Technical ROM보다 효과적인 것으로 나타났다. 이는 본 연구에서 개발한 EV ROM이 댐 유역뿐만 아니라 댐 하류 홍수제어지점의 수문상황을 동시에 고려하여 댐의 방류계열을 결정하였기 때문이다. 향후, 본 연구에서 개발된 EV ROM을 다양한 홍수사상에 적용하기 위해서는 예측강우량의 정확도 개선과 함께 프로그램의 지속적인 보완이 이루어져야 할 것이다.