DOI QR코드

DOI QR Code

역지밸브 채터링 현상 해소방안 연구

A Study on the Chattering Phenomena of a Check Valve

  • 유기완 (전북대학교 공과대학 기계항공시스템공학부) ;
  • 이준신 (한전 전력연구원 원자력연구실) ;
  • 김태룡 (한전 전력연구원 원자력연구실)
  • 발행 : 2002.01.01

초록

The cause and the elimination method for the chattering phenomena were investigated in a check valve attached to the exit of an auxiliary cooling water pump in a Korean nuclear powerplant. From the site experiment and the numerical calculation, the incident angle of the disk was so small that it was not able to produce the sufficient lifting force to overcome the gravitational component of the disk weight. Moreover, it turned out that the installation position was not symmetric for the secondary vortical flow generated inside the elbow so that the flow structure had strongly unstable flow characteristics. From this study, the tapping noise and the chattering phenomena were eliminated exactly by changing the incidence angle of the valve disk and the installation position of the calve body.

키워드

참고문헌

  1. 유기완, 이준신, 손석만, 김태룡, 2000, "고리1호기 보조냉각계통의 역지밸브 채터링 해소방안 연구." KEPRI TM.S01.S2000.21.
  2. Kim, T. R. Ryu, K. W., and Lee, J. S., 2000, "An Experience on the Elimination of Check Valve Chattering in Korean NPP," ASME Pressure Vessel and Piping Conference, Jul. 23-27, Seattle. Washington.
  3. Sabersky, R. H., Acosta, A. J., and Hauptmann, E. G., 1971. Fluid Flow, 2nd edition. Collier-McMillan.
  4. Idelchick, I. G. 1993. Handbook of Hydraulic Resistance, CRC Press.
  5. CRANE Co., 1988. "Flow of Fluids Through Valves, Fittings, and Pipe." Technical Paper No. 410M.
  6. McDonald, D. E., 1993. "Application Guide for Check Valves in Nuclear Powerplants," Revision 1. EPRI NP-5479.