An Experimental Study on Isolation System of Aerial Gas Pipeline for Vehicle Vibration

차량진동에 대한 노출가스관의 방진 시스템 개발을 위한 실험적 연구

  • 박연수 (전남대학교 공과대학 토목공학과) ;
  • 강성후 (동신대학교 공과대학 토목공학과) ;
  • 박선주 (동신대학교 공업기술연구소)
  • Published : 2001.08.01

Abstract

In this paper, aerials gas pipeline vibrations due to the passing of vehicles have been measured, and peak values and characteristics of vibration were analyzed. In order to develop isolation system for gas pipeline, six cases with various support condition and hanging method were tested. The hanger used instead of wore rope isolated almost all vibrations transmitted from main beam. In the results of test, we could decrease response of vibration velocity from 49 % to 56 % and response of vertical vibration acceleration from 49 % to 60 %, because hanger instead of wire rope was used and rubber pads instead of wooden shield plates at support positions for Proofing horizontal vibration were used.

Keywords

References

  1. Noise and Vibration Control Engineering Leo L.B.;Eric E.U.
  2. 한국가스공사 연구개발원 v.5 발파진동에 의한 가스관의 안전성 평가 박연수(등)
  3. 추계학술발표회 논문집 차량하중하에서 가스관의 진동측정 및 평가 박연수(등)
  4. Vibration Testin. Kenneth G.M.
  5. Impact-Echo : Nondestructive Evaluation of Concrete and Masonary Mary J.S.;William B.S.