구치부 레진 수복 재료의 가수분해

HYDROLYTIC DEGRADATION OF POSTERIOR RESIN RESTORATIVE MATERIALS

  • 양규호 (전남대학교 치과대학 소아치과학교실 및 치의학 연구소) ;
  • 박미란 (전남대학교 치과대학 소아치과학교실 및 치의학 연구소) ;
  • 최남기 (전남대학교 치과대학 소아치과학교실 및 치의학 연구소) ;
  • 박은혜 (전남대학교 치과대학 소아치과학교실 및 치의학 연구소)
  • Yang, Kuy-Ho (Department of Pediatric Dentistry, Dental Science Research Institute Chonnam National University) ;
  • Park, Mi-Ran (Department of Pediatric Dentistry, Dental Science Research Institute Chonnam National University) ;
  • Choi, Nam-Ki (Department of Pediatric Dentistry, Dental Science Research Institute Chonnam National University) ;
  • Park, Eun-Hae (Department of Pediatric Dentistry, Dental Science Research Institute Chonnam National University)
  • 발행 : 2001.11.30

초록

우수한 심미성 수복재료로서 복합레진은 그 사용 빈도가 증가하고 있다. 이런 증가 추세에도 불구하고 복합레진의 부적절한 마모저항성 때문에 구치부 수복에서의 사용이 제한되어왔다. 이와 관련된 인자로 수복물의 표면하 분해가 고려되고 있다. 본 연구에서는 복합레진의 마모에 미치는 환경적 분해의 효과를 알기 위해 알카리성 용액(0.1N NaOH)에 현재 많이 사용되는 Definite($Degussa-H\ddot{u}ls$ AG, Germany), Prodigy(Kerr, USA), Pyramid(Bisco, USA) 및 Synergy(Coltene, Swiss) 등 4종의 복합레진을 보관하였을 때 각 제품의 분해과정을 평가하고자 하였다. 각 제품 당 3개의 시편을 제작한 후 0.1N NaOH용액에 저장하여 $60^{\circ}C$에서 보관하였다. 2주 후 제거하여 HCl로 중화, 세척 후 $60^{\circ}C$에서 건조하였다. 무게 손실, 분해층 깊이, Si농도 등을 기준으로 분해저항성을 평가하여 다음과 같은 결과를 얻었다. 1. 무게 손실은 Synergy에서 $1.24{\pm}0.002%$로 가장 높은 값을 보였으나 각 제품간 유의한 차이는 보이지 않았다. 2. 분해층 깊이는 Synergy에서 $107.83{\pm}2.52{\mu}m$로 가장 높은 값을 보였고, Synergy를 제외한 다른 제품에서는 유의한 차이를 보이지 않았다. 3. Si 용출량에 있어서는 4가지 제품 모두 차이를 보이지 않았다. 4. 무게 손실과 분해층 깊이 사이에는 높은 상관 관계를 보였다(r=0.6127, p<0.05). 5. 무게 손실과 Si 용출량, 분해층 깊이와 Si 용출량 사이에 상관 관계는 없는 것으로 나타났다. 6. 주사전자현미경 관찰시 NaOH 용액에 보관한 후 레진 기질과 필러 사이의 결합 파괴를 관찰할 수 있었다.

The use of resin composites has continued to increase over the last several years. In spite of their growing popularity, composites continue to exhibit a number of undesirable characteristics. One of the major deficiencies of composite restorative resins is their inadequate resistance to wear. Of the multitude of factors that have been associated with wear, subsurface degradation within the restoration is considered to be one. The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. This solution with a high concentration of hydroxyl ions is a convenient medium for accelerated degradation of silane coupling and filler particles. The brands studies were Definite($Degussa-H\ddot{u}ls$ AG, Germany), Prodigy(Kerr, USA), Pyramid(Bisco, USA) and Synergy(Coltene, Swiss). Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters : (a) mass loss(%)-determined from pre-and post-exposed specimen weights : (b) Si loss(ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation $depth({\mu}m)$-measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. Mass loss of Synergy was $1.24{\pm}0.002%$, it was the highest, there was no significant difference among the materials. 2. The degree of degradation layer depth of Synergy was $107.83{\pm}2.52{\mu}m$, it was the highest, there was no significant difference among any other materials than Synergy. 3. There was no difference among the four materials in Si loss. 4. The correlation coefficient between mass loss and degradation depth was relatively high(r=0.06, p<0.05). 5. There was no coefficient correlation between Si loss and mass loss, the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler.

키워드