• 제목/요약/키워드: Composite resins

검색결과 447건 처리시간 0.029초

Wear resistance of indirect composite resins used for provisional restorations supported by implants

  • Tsujimoto, Akimasa;Jurado, Carlos;Villalobos-Tinoco, Jose;Barkmeier, Wayne;Fischer, Nicholas;Takamizawa, Toshiki;Latta, Mark;Miyazaki, Masashi
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권4호
    • /
    • pp.232-238
    • /
    • 2019
  • PURPOSE. The aim of this study was to investigate simulated localized and generalized wear of indirect composite resins used for implant supported provisional restorations. MATERIALS AND METHODS. The study investigated ten indirect composite resins. Two kinds of wear were simulated by 400,000 cycles in a Leinfelder-Suzuki (Alabama) machine. Localized wear was simulated with a stainless-steel ball bearing antagonist and generalized with a flat-ended stainless-steel cylinder antagonist. The tests were carried out in water slurry of polymethyl methacrylate beads. Wear was measured using a Proscan 2100 noncontact profilometer in conjunction with Proscan and AnSur 3D software. RESULTS. Both localized and generalized wear were significantly different (P<.05) among the indirect composite resins. SR Nexco and Gradia Plus showed significantly less wear than the other indirect composite resins. The rank order of wear was same in both types of wear simulation. CONCLUSION. Indirect composite resins are recommended when a provisional implant-supported restoration is required to function in place over a long period. Although only some indirect composite resins showed similar wear resistance to CAD/CAM composite resins, the wear resistance of all the indirect composite resins was higher than that of bis-acryl base provisional and polymethyl methacrylate resins.

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.

피톤치드를 함유한 복합레진의 기계적 특성 및 Streptococcus mutans에 대한 항균 효과 (Mechanical properties and antibacterial effects on Streptococcus mutans of composite resins containing phytoncide)

  • 이명진;김단비;김지은;문승하;손지영;이은영;권재성
    • 한국치위생학회지
    • /
    • 제19권4호
    • /
    • pp.467-477
    • /
    • 2019
  • Objectives: The aim of this study is to investigate the mechanical properties and antibacterial effects on Streptococcus mutans of composite resins containing phytoncide. Methods: Phytoncide was mixed with commercial composite resins at 0 (control), 1.25, 2.5, 3.75, and 5.0 weight percentage (wt%). Mechanical properties related to composite resins such as surface hardness, depth of cure, and flexural strength were measured. Antibacterial effects of composite resins were analyzed by using Streptococcus mutans (ATCC 25175). The results were analyzed by one-way analysis of variance followed by Tukey's test (p<0.05). Results: Composite resins that contain low wt% of phytoncide demonstrated no significant difference in surface hardness, depth of cure, and flexural strength (p>0.05). However, composite resins that contain high wt% of phytoncide had significantly decreased mechanical properties (p<0.05). In terms of antibacterial effects, composite resins containing phytoncide inhibited the growth of S. mutans. Conclusions: Our findings suggest that novel composite resins containing phytoncide have effective antibacterial properties while maintaining the originally important mechanical features of composite resins.

복합레진의 표면 광택에 대한 평가 (Evaluation of surface gloss of composite resins)

  • 변지은
    • 대한치과의료관리학회지
    • /
    • 제11권1호
    • /
    • pp.38-46
    • /
    • 2023
  • Composite resins, commonly used in clinical practice, have been developed to improve aesthetics to obtain smooth surfaces. Although the restored composite resin has a smooth surface, it gradually becomes rough over time. Therefore, this study measured glossiness to evaluate the surface of various composite resins and attempted to evaluate the maintenance of glossiness of composite resins by observing surfaces that change to roughness. Specimens were produced using resin used in clinical practice: Gradia direct anterior (GA), Tetric N-Ceram (TN), Ceram.X Sphere TEC one (CX), Filtek Z350XT (FT), Estelite sigma quick (ES). After creating a smooth surface with slide glass, five locations were randomly selected to measure surface gloss, and the average was the representative value of the specimen. Roughness was applied to the specimen under water pouring at the same speed and pressure using SiC paper #2400, 1200, and 400. The gloss unit of different SiC papers was measured. To evaluate the gloss unit and gloss retention between composite resins, one-way analysis of variance and Tukey multiple comparisons test were used. As a result of the study, there was a difference in gloss unit of specimens produced under the same conditions. Although the degree differed depending on the composite resin, there was also a difference in gloss retention. Based on the findings, composite resins show differences in gloss due to their different characteristics. Ceram.X Sphere TEC one (CX) showing the lowest gloss retention and Estelite sigma quick (ES) showing the highest.

광중합 복합레진에 대한 가열처리 피로내성 및 중합수축에 미치는 영향 (A Fatigue Toughness and Polymerization Shrinkage of Post-cure Heat Treated Composite Resins)

  • 오원만;류선열;손호현;리이치 오쿠다;다쓰오 엔도;요시유키 쿠도
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.135-147
    • /
    • 1994
  • This study was conducted to evaluate whether the fatigue toughness of visible light cured composite resins could be improved and how much percentage of polymerzation shrinkage could be affected by additional heat treatment. 7 materials were investigated for this study: P-50, Lite-fil CR inlay, Pekafil, Clearfil CR inlay, Clearfil photo posterior, Z -100 and Progress. Diametral tensile strengths and linear shrinkages of composite resins were taken under visible light cured and additional post-cure heated condition and compared each other. A fatigue toughness of above materials was evaluated by measuring diametral tensile strength after they were repeatedly loaded with 120kgf/$cm^2$ up to 3000 cycles. The results obtained were as follows : 1. When composite resins were cured just by visible light, Lite fil CR inlay, Z -100 and Progress showed respectively higher diametral tensile strength than the other materials. Clearfil CR inlay, Clearfil photo posterior and Progress exhibited strong fatigue toughness compared to P-50 and Pekafil. 2. Post-cure heat treated composite resins had higher diametral tensile strengths than visible light cured composite resins at fatigue toughness test as well as no fatigue toughness test. 3. When Composite resins were additionally polymerized by post-cure heat treatment, P-50 showed weak fatigue toughness, on the contrary, Clearfil CR inlay, Z-100, Progress showed strong one. 4. When composite resins were cured just by visible light, percentage of polymerization linear shrinkage was the lowerest in Clearfil CR inlay, followed by, in ascending order, Clearfil photo posterior, Lite-fil CR inlay, Progress, Pekafil, P-50, and Z-100. In the case of post- cure heat treated composite resins, percentage of linear shrinkage was the lowest in Clearfil photo posterior, followed by, in ascending order, Lite-til CR inlay, Clearfil CR inlay, Progress, P-50, Pekafil and Z-100. 5. Percentage of polymerization linear shrinkage was greater in the post-cure heat treated composite resins than in the visible light cured composite resins and linear shrinkage increased significantly in Pekafil, Clearfil CR inlay, and Clearfil photo posterior between at the visible light cured and at the post-cure heat treated condition. The above results is saying that additional post-cure heat treatment on the composite resins for posterior restoration is able to affect on improvement of strength and fatigue toughness and lead to increase polymerization of composite resins.

  • PDF

수종의 복합레진에 대한 미세경도와 변연적합도 비교 (A study on the microhardness and the marginal fitness of the various composite resins)

  • 김소민;조자원;황경숙;김욱태;강유화;김남중
    • 대한치과기공학회지
    • /
    • 제33권2호
    • /
    • pp.147-156
    • /
    • 2011
  • Purpose: The author performed experiments on the microhardness and the marginal fitness of composite resins after polymerizing 4 kinds of composite resins on MOD standard specimens. Methods: For this study, in order to compare the microhardness and the marginal fitness of 4 kinds of composite resins. Results: The results are as follows. 1. In case of the microhardness, Tescera scored the highest among the four kinds of composite resins. 2. In case of the marginal fitness, Premise Indirect scored the highest. However, there was no statistically significant difference, all staying in clinically practical range. 3. Considering the above results, among the four kinds of composite resins, the author advises to use Tescera during teeth restoration which scored the highest in the micro- hardness. Conclusion: Conclusion: All of the composite marginal fitness were within the clinically useful range.

나노필러를 포함하고 있는 복합레진의 중합특성 (Characteristics of polymerization in nanofiller-containing composite resins)

  • 이희경
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.9-15
    • /
    • 2007
  • As the development of nanotechnology, the use of composite resins which containing nanofillers becomes popular. The purpose of this study was to test the degree of polymerization of nanofillercontaining composite resins. For the study, three different nanofiller-containing composite resins and two different light-curing units were used. To evaluate the degree of polymerization, the maximum polymerization shrinkage taking place during the light curing, and the microhardness, after the light curing, were measured. As results, two light-curing units exhibited a similar emission spectrum to that of the included photoinitiator, camphorquinone. The only difference between the light-curing units were the width of the emission spectrum. Three different composite resins showed different microhardness values. Among them, Grandio showed the greatest microhardness value. However, there was less microhardness difference on the top and bottom surfaces due to the difference of the light-curing units. The maximum polymerization shrinkage values were also similar in the tested specimens regardless of the difference of the light-curing units. However, Grandio showed the least polymerization shrinkage. According to the manufacturers' data, Grandio showed the highest filler content(vol%).

  • PDF

광중합형 복합레진의 압축강도에 미치는 레진과 필러의 영향 (The Effect or Resin ann ruler Type on the compressive strength of Light-activated Composite Resins)

  • 원대희
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 1997
  • This study was performed to evaluate the effect of resin and filler type on the compressive strength of light-activated composite resins. Experimental composite resins containing either amorphous spherical silica or crushed quartz in two matrix resins of BisGMA/TEGDMA and UTMA/TEGDMA were prepared and the specimens of 3 m in diameter and 6m in length were made. Compressive test was subjected to a crosshead speed of 0.5 mm/min, and the fracture surFaces were examined by SEM. The compressive strength of UTMA-based composite resin was higher than that of BisGMA-based composite resin. The loading rate of spherical silica was higher than that of crushed silica when the size dis- tribution of fillers was same. Strength decrease of Bis-GMA-based composite resin was severer than that of UTMA-based composite resin in a $37^{\circ}$c water environment. Fracture surface showed that the composite resin failure developed along the matrix resin and the filler/resin interface region.

  • PDF

새로운 광증감제를 사용한 치과용 광중합형 복합레진의 기계적 특성 (Physical Properties of Light Cured Dental Composite Resin with Novel Photosensitizers)

  • 선금주;이희경
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: The purpose of this study was to know the physical properties of UDMA dental composite resins containing two photosensitizers, PD, DA, as a photosensitizer instead of CQ. We want to know Remaining Double Bond(RDB) of UDMA unfilled resin and diametral tensile strength and flexural strength of composite resin containing PD and DA were compared with those of CQ, most widely used photosensitizer for dental composite resins. Methods: The RDB of UDMA studied by FT-IR spectroscopy increased with irradiation time. The composite resins were tested for their physical properties. The dental composite resins were made with UDMA as a monomer, silanized silica as filler, N,N-dimethylaminoethyl methacrylate (DAEM) as amine initiator, and one of the two kinds of new photosensitizers. Results: The relative RDB of UDMA was in the order: DA > CQ > PD but the physical properties of the composite resins show PD and DA with higher results compared with that containing CQ. The reason for the results is that PD and DA serve not only as a photosensitizer but also as a photo-crosslinking agent. Conclusion: PD and DA show as effective photosensizers, suitable for UDMA dental composite resin compare with a higher efficiency than CQ.

수복용 레진과 인공치아간의 결합강도 연구 (Study on shear bond strength of various composite resins to artificial denture teeth)

  • 박경모
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.171-177
    • /
    • 2014
  • Purpose: The dental medicine has been preparing the custom-made service to meet the requirements of the aged society, while the average span of human life is growing more and more, and the full denture is a representative of them. It is causing great concern in these atmosphere of society, and demands for it are expected to increase. The full denture is a uniform combination of denture base and artificial teeth using polymerization, and is most influenced by change of physical properties of denture base and bonding strength with artificial teeth. Methods: In this study, the samples were made of composite resin combined with occlusion surface of artificial teeth undergone mechanically surface treatment to evaluate the bonding strength of composite resin for repairing artificial teeth. The resin teeth used in this study are 3 types artificial teeth. And 3 types of composite resins are used that are various polymerization resin. The shear strength of composite resins made in various polymerization ways to resin teeth was measured to evaluate bonding strength of artificial teeth to each composite resins. Results: Surface hardness's results on Trubyte Biotone(74.58Hv), Biotone IPN(70.06Hv), Endura Posterio (64.48Hv). Results of bonding strength of artificial teeth to composite resins on ES samples(8.73Mpa), IF(4.37Mpa) and IZ(3.84Mpa). Conclusion: 1. The Trubyte Biotone(74.58Hv) was first, followed by Biotone IPN(70.06Hv), and Endura Posterio(64.48Hv) in surface hardness's results of worn sides using hardness test. 2. The ES samples(8.73Mpa) showed significant differences with IF(4.37Mpa) and IZ(3.84Mpa) (p<0.05), but not other samples(p>0.05) in results of bonding strength of artificial teeth to composite resins.