A Control Value Analysis on the Axial Force of Braced Excavation Walls Used In Korea

국내 적용되고 있는 흙막이구조물의 축력에 대한 관리기준치 분석

  • 정상국 (송원대학 철도시설토목과) ;
  • 이광찬 (동신대학교 토목환경공학부) ;
  • 이송 (서울시립대학교 토목공학과)
  • Received : 2000.07.11
  • Published : 2000.10.31

Abstract

This study aims to present a more reasonable control value than the exiting one by comparing and analyzing control values and field instrumentation values of the whole excavation depth of the four case sites using geometric averaging as a statistical method. The range of the study is confined to three things: (1) the axial force of the braced excavation walls among a variety of items prescribed in the control values by stress deformation of walls and adjacent structures; (2) by approximation of the allowable and design value; (3) and by safety factor. As a res it is desirable to revise "(Long term allowable stress + Short term allowable stress)/2 ~ Short term allowable stress," presented in the present control values by stress deformation of walls and adjacent structures, to "(Long term allowable stress + Short term allowable stress)/5 ~ (Short term allowable stress)/3." The result also shows that since there is a difference of about 3.5%, it is not necessary to revise 70, 90, and 100 percent of LEVEL I, II, and III, prescribed in the control values by the allowable and design value approximation. In addition, modifying the control value by the safety factor, now 1.07, is unnecessary, although it varies little difference from the present value.

Keywords