25mm NSW-ring, pp.를 충진한 충진탑에서 암모니아 흡수에 의한 유해가스 처리시 충진물의 특성연구

A Study on Charateristic of Modern Packing, 25mm NSW-ring, ppm by Absorption of NH3 gas

  • 신은재 (동아대학교 환경공학과) ;
  • 박진식 (동아대학교 환경공학과, 국립밀양산업대학교 환경공학과)
  • 발행 : 1997.08.01

초록

The study was carried out to demonstrate the superiority of used packing in view of energy saving and efficiency of mass transfer, comparing with conventional packing. The results are as follows : 1. Owing to low Pressure drop under high load. 25mm NSW-ring, pp. can cause energy saving 2. The unique magnitudes of used packing are as follows $C_G$=5.78, m=0.67, n=0.46 3. Used packing can make high efficiency including energy saving because of low pres sure drop per the number of transfer unit. To rate the characteristic of packing, It should be carried out that the measurement of pressure drop per packing height and per the number of transfer unfit. This study demonstrated the superiority of used packing by carring out above experiment and could be used as basic reference for design and predicting efficiency of packing tower which is tilled with same packing.

키워드

참고문헌

  1. 동아대학교 한림 정수봉 총장 회갑기념 논총 격자형 충진물을 이용한 충진탑내의 액체와 가스상의 역류에 의한 물질전달 김장호
  2. 동아대학교 환경문제연구소 연구보고 v.15 no.2 충진탑에서의 흡수와 수력학적 특성연구 김장호
  3. 한국해양공학회지 v.2 no.2 격자형 충진물을 이용한 충진탑내 기액상의 역류에 의한 물질전달과 수력학적 동특성 김장호;하상안
  4. The Chemical Engineering Journal v.32 Ammonia Absorption into Water in a Packed Tower II : Measurement of Mass Transfer Coefficients G.R.Lightsey;P.L.Spedding;M.T.Jones
  5. The Chemical Engineering Journal v.32 Ammonia Absorption into Water in a Packed Tower I :Characterization of Packing and Liquid Distribution P.L.Spedding;P.A.Munro;M.T.Jones
  6. Packed column analysis and design Reinhard Billet
  7. Energieeninsparung bei Thermischen Stofftrennverfahren Dr R.Billet
  8. 동아대학교 환경문제연구소 연구보고 v.2 no.2 역류가스 흡수에 의한 대기오염방지 기술 R.Billet;Kim Jang-Ho;Ha Sang-An
  9. 충진탑 기술 R.Billet;Kim Jang-Ho
  10. Chem.-Ing.-Tech. no.2 Bewertung von Fllkrpern und die Grenzen ihrer Weiterentwicklung R.Billet
  11. Chem. Eng. Technol. no.11 Relationship between Residence Time, Fluid Dynamics and Efficiency in Countercurrent Flow Equipment R.Billet
  12. Aus anlass der 25jhrigen bestehens der RUHRUNIVERSITT BOCHUM The relationship between mass transfer and pressure drop in counter current packed column R.Billet
  13. Perry's Chemical Engineer's Handbook(6th) Robert H.;Perry Don Green