DISTRIBUTION OF VESSEL NOISES IN THE SAE-BA-DA

새바다호의 선박소음 분포에 관한 연구

  • Published : 1979.09.01

Abstract

In this paper, the noise pressure propagated in the air on account of the engine revolution of a stern trawler, Sae-Ba-Da(G. T. 2275.71) was measured at the check points No.1 through No.43 when the vessel was cruising, towing nets, and drifting. The experiment was carried out in the period from August 23 to October 22, 1978 at the locations of lat. $33^{\circ}$ 47'N, long. $127^{\circ}$ 34'E; lat. $34^{\circ}$ 24'N, long. $128^{\circ}$ 23'E; and lat. $6^{\circ}$ 01'N, long. $108^{\circ}$ 04'E. In case of cruising, noise on the weather deck came from funnel noise. The highest noise pressure was 92dB at observation point No.9 where tile noise pressure from main engine was 105dB when the engine was operated at 730rpm and $12^{\circ}$ sorely propeller pitch. The noise measured was reduced to 90dB at observation point No.9 when the screw propeller pitch was changed to $8^{\circ}$ that resulted in reduction of engine to 103dB. In case of towing net, the main engine revolution and screw propeller pitch was fixed at 730rpm and $8^{\circ}$ respectively. But the engine noise pressure was increased up to 106dB due to the towing resistance by 14 tons of the nets, and the noise pressure was 90dB at No.9 point. A hight noise was also generated from screw because of the towing reoistance and could be measurable even in the wall of the insulated freezing room. When the vessel was drifting: the noise pressure from the generator operated, at 720rpm was 100dB. This caused 87dB noise pressure at No.9 point. The noise pressure in the boarding or residence sections was 45 to 60dB in each case of cruisinrg towing net or drifting but it was so high as 82dB on the open deck that voice could hardly be heap.

1978년 8월 23일 부터 동년 10월 20일 사이에 우리 나라의 남부와 싱가폴 북부 해상에서 새바다호의 순항, 예망, 표박시의 선박소음에 관하여 실험한 결과를 요약하면 다음과 같다. 1. 외부 갑판상의 가장 높은 소음원은 연돌로 돌출하는 배기소음이고, 연돌뒤(No.9)에서 순항, 예망, 표박시 92,90,87dB로 가장 높았으며, 선수(No. 1)에서 65,63,53dB로 가장 낮았다. 2. 학생 거주구역에서는 주기소음보다 통풍기나 에이콘의 가동소음이 주소음원을 이루었는데 통풍기를 가동하면 표박할때와 에이콘을 가동하면서 순항때를 비교하면, 출입구(No. 14)에서 85,69dB로 가장 높았고 학생실(No. 22)에서 45,40dB로 가장 낮았다. 3. 중앙부의 선원거주구역에서는 순항소음압이 예망소음압보다 2dBwjd도로 선원식당(No. 30)까지는 높게 나타났고, 급냉실(No. 31)로 부터는 반대로 낮게 측정 되었다. 또 이 구역에서는 출입문을 닫았을 때 선장실(No, 25)에서 13dB, 선원식당(No, 30)에서 3dB씩 낮아졌다. 4. 순항시 주기소음압은 Pitch $8^{\circ}$$12^{\circ}$때 103, 105dB 였는데, Pitch $8^{\circ}$로 예망시는 106dB로서 3dB의 증가를 보였다. 5. 선형과 기관이 같은 오대산호와 소음을 비교 하면 식당, 싸롱, 학생식에서 $4\~6dB$씩 낮았고 작업갑판상에서는 14dB나 높은 음압이였다.

Keywords