Abstract

It was intended to evaluate whether the primer affects the physical performance of the waterproofing membrane coating. For this end, the physical performance change of the urethane waterproofing membrane coating was evaluated for urethane-based and polymer-based primers. As a result of the evaluation, it was confirmed that the type of primer may affect the physical performance of the waterproofing membrane coating. In particular, a difference in performance of more than 100% was confirmed in tensile strength and percentage elongation. Through these results, it was confirmed that the selection of the primer was important. In the future, follow-up studies on various waterproofing membrane coatings are needed.