• Title/Summary/Keyword: waterproofing membrane coating

Search Result 24, Processing Time 0.025 seconds

A Study on the Physical Properties Change of Waterproofing Membrane Coating by Application of Modified Polymer Primer (개질 폴리머계 프라이머 적용에 따른 도막 방수재의 물리적 특성 변화 연구)

  • Lee, Jung-Hun;Cho, Hong-Bum;Jeon, Hyun-Soo;Park, Ki-Hong;Kim, Jin-Sik;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.191-192
    • /
    • 2022
  • It was intended to evaluate whether the primer affects the physical performance of the waterproofing membrane coating. For this end, the physical performance change of the urethane waterproofing membrane coating was evaluated for urethane-based and polymer-based primers. As a result of the evaluation, it was confirmed that the type of primer may affect the physical performance of the waterproofing membrane coating. In particular, a difference in performance of more than 100% was confirmed in tensile strength and percentage elongation. Through these results, it was confirmed that the selection of the primer was important. In the future, follow-up studies on various waterproofing membrane coatings are needed.

  • PDF

Salt damage resistance of mortar substrate coated by the urethane and acrylic waterproofing membranes (우레탄계와 아크릴계 도막 방수재가 도포된 바탕 모르타르의 염해 저항성 평가)

  • Lee, Jun;Miyauchi, Hiroyuki;Koo, Kyung-Mo;Choe, Gyeong-Cheol;Miyauchi, Kaori;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.329-331
    • /
    • 2013
  • The salt damage resistance of waterproofing membrane was evaluated on the cracked mortar substrate. The types of specimens are urethane, acrylic waterproofing membrane, and no coating mortar substrate. After these specimens were cured by water curing for 4 weeks, they were cured by atmospheric curing at 20±2Co for 8 weeks. The salt water immersion test was carried out by following KS F 2737, and the penetration depth of chloride ion into substrate was measured in 1, 4, 8, and 13 weeks. As a result, in the case of non coating specimen, the chloride ion penetrated within one week. In the coated specimens, a regardless of the membrane type, the chloride ion did not penetrate during 13 weeks-tests on condition that the cracked width of substrate is less than 0.3mm. Also, the penetration speeds of the coated specimens were lower than that of non coating specimen. Therefore, our results reached a conclusion that waterproofing membrane has high salt damage resistance.

  • PDF

Research on Separation Behavior Joint of Develop and Application in Sheet-Membrane Composite Waterproofing (시트-도막을 이용한 분리거동형 복합방수공법 개발 및 적용에 관한 연구)

  • Heo, Neung-Hoe;Kim, Dong-Bum;Oh, Je-Gon;Go, Gun-Woong;Go, Jang-Ryeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.165-166
    • /
    • 2014
  • The Composite waterproofing began to rise gradually 2000s in domestic. However, the sheet-membrane composite waterproofing method also acts as an abutment vulnerability that was a problem in a single method, and had the problem of damage to the formation of leakage paths. The existing non-overlap method, through vigorous research abutting sheet shall or could be developed to improve the seal performance of this method with the I-type joint coating material. Nevertheless, it has an integral top coat paint membrane and a sheet abutment limitation, damage to the upper membrane is damaged junction coating membranes has been generated. In this study, a method that has a layer of insulation on the joint bond breaker concept development, and to determine the physical properties with insulated joints to determine the breaking off of the upper joint is damaged coating membrane and tensile performance.

  • PDF

A Research on Development of Eco-friendly Polyurethane Waterproofing Membrane Coating of Exposed Type (재활용 소재를 활용한 친환경 노출형 폴리우레탄 도막방수재 개발에 관한 연구)

  • Kim, Dong-Bum;Heo, Neung-Hoe;Oh, Je-Gon;Go, Gun-Woong;Go, Jang-Ryeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.161-162
    • /
    • 2014
  • The subject of this study, Eco-friendly Polyurethane Waterproofing Membrane Coating of Exposed Type is manufactured by replacing environmental hazardous substance such as Toluene, Dioctyl Phthalate with Dimethyl Carbonate, waste-soybean oil. As part of existing filler is also replaced with waste-rubber chip and waste-soybean oil. As a result of environment friendly tests, in test of detection of VOCs case was contented with the Ministry of Environment standards at 5% below. Testing methods for heavy metal extracted was contented with standards for official wastes test method. So it is judged that environment friendly is secured.

  • PDF

A Study on Waterproofing and Anticorrosive Performance Evaluation of Polyurea Resin Waterproofing Membrane Coating of Velocity per Second Hardening (초속경화(初速硬化) 폴리우레아수지 도막방수재(途膜防水材)의 방수(防水)·방식(防蝕) 성능평가(性能評價)에 관한 연구(硏究))

  • Cho, Chan-Haeng;Kang, Hyo-Jin;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.91-95
    • /
    • 2003
  • There is a problem to be solved for improvement of durability and safety supervision. When you do the waterproofing and anticorrosive work of main concrete from the design stage, the material and method of construction need to be correctly applied to appropriate circumstance conditions. Epoxy have mostly been used for concrete water tank structure. Lately, lots of subjects on adaption of polyurea resin waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with another waterproofs in this study. Performance evaluation items include the adherence performance, the imprint of seal performance, temperature dependence performance, promotion weatherizing ability, inner chemical performance, drinking water eruptive performance. Through the experiment analysis, we found that the polyurea resin waterproofing membrane is dominantly superior to other waterproofs. According to this study, we suggest the polyurea resin waterproofing membrane as a new waterproofing material for concrete structure.

  • PDF

A Study on Waterproofing Performance Evaluation of Polyurea Resin Waterproofing Membrane Coating of Velocity per Second Hardening (뿜칠형 초속경화 폴리우레아수지 도막방수재의 성능평가에 관한 연구)

  • Oh, Sang-Keun;Kim, Su-Ryun;Lee, Sung-Il
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.1
    • /
    • pp.131-138
    • /
    • 2002
  • There is a problem to be solved for improvement of durability and safety supervision. When you do the waterproofing work of main concrete from the design stage, the material and method of construction need to be correctly applied to appropriate circumstance conditions. Epoxy have mostly been used for concrete water tank structure. Lately, lots of subjects on adaption of polyurea resin waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with another waterproofs in this study. Performance evaluation items include the adherence performance, the imprint of seal performance, temperature dependence performance, promotion weatherizing ability, Inner chemical performance. drinking water eruptive performance. Through the experiment analysis, we found that the polyurea resin waterproofing membrane is dominantly superior to other waterproofs. According to this study, we suggest the polyurea resin waterproofing membrane as a new waterproofing material for concrete structure.

A Study on Waterproofing and Anticorrosive Performance Evaluation of Polyurea Resin Waterproofing Membrane Coating of Velocity per Second Hardening (초속경화 폴리우레아수지 도막방수재의 방수.방식 성능평가에 관한 연구)

  • 조찬행;강효진;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.91-95
    • /
    • 2003
  • There is a problem to be solved for improvement of durability and safety supervision. When you do the waterproofing and anticorrosive work of main concrete from the design stage, the material and method of construction need to be correctly applied to appropriate circumstance conditions. Epoxy have mostly been used for concrete water tank structure. Lately, lots of subjects on adaption of polyurea resin waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with another waterproofs in this study. Performance evaluation items include the adherence performance. the imprint of seal performance, temperature dependence performance. promotion westernizing ability, inner chemical performance. drinking water eruptive performance. Through the experiment analysis, we found that the polyurea resin waterproofing membrane is dominantly superior to other waterproofs. According to this study, we suggest the polyurea resin waterproofing membrane as a new waterproofing material for concrete structure.

  • PDF

Oil Leakage Characteristics of Asphalt Mastic Waterproofing Membrane Coating According to Particle Size and Content of Organic/Mineral Extender (유·무기질 체질안료 입도 및 함량에 따른 아스팔트 매스틱 도막방수재의 누유 특성)

  • Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo;Kim, Young-Sam;Shin, Hong-Chol;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.1
    • /
    • pp.51-59
    • /
    • 2021
  • In this study, the purpose of this study was to quantitatively grasp the specific correlation between the raw material and the occurrence of leakage by analyzing the characteristics of leakage by adjusting the type and content of the raw material constituting the asphalt mastic coating waterproofing material. To this end, two raw materials, CA (calcium carbonate) and ASE (anti-sedimentation), which are organic and mineral extender for asphalt mastic waterproofing membrane coating, were selected. viscosity and oil leakage stability (20 ℃, 40 ℃) was evaluated. As a result of the evaluation, the oil leakage stability and viscosity were inversely proportional to the CA average particle size, and it was quantitatively proven that a correlation in proportion to the ASE content was established. The results of this study are expected to be used as core data for basic mixing design in the future mixing studies to improve leakage of asphalt mastic waterproofing membrane coating.

A study on a performance the appliable rubber asphalt of monolithic waterproofing material of construction quality and the cement polymer modified waterproof coating membrane material of surface treatment. (무기질계 탄성 도막재와 고무 아스팔트를 적층한 일체형 방수재의 시공특성에 관한 실험적 연구)

  • Park Jin-Sang;Choi Sung-Min;Park Young-Tea;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.223-226
    • /
    • 2005
  • In this study on the appliable Asphalt sheet of monolithic and inorganic matter waterproofing ,Fing material using of field because of problem of complex waterproofing sheet. Before this cement polymer modified waterproof coating and appliable asphalt sheet of monolithic whether have stability by method of construction about all style waterproofing that evaluate to new method of construction development naturally big emphasis put and try to approach. Did performance test item first at, as a result, drew by suitable thing in all KS items. This is considered to have more effective spot construction work because if means that have stability by material as well as method of construction.

  • PDF

An Experimental Study about appling non-Exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Self adhesive Rubberized Asphalt sheet to the Roof Structure. (무기질계 탄성 도막재와 자착식 고무 아스팔트 시트를 결합한 지붕구조물 비노출 방수공법에 관한 실험적 연구)

  • Moon, You-Seok;Lee, Sun-Gyu;Song, Je-Yeong;Gwak, Gyu-Seong;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.613-616
    • /
    • 2008
  • This study is about appling non-exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Selfadhesive Rubberized Asphalt sheet to the Roof Structure, Because there are a lot of problems in previous methods. So We had the performance tests using waterproofing method which combines two materials, and we analyzed the results. This study showed us very important results. We had bond strength test and tensile test under high, normal and low temperature, and the results were successful. And we also tested for coping with crack and movement. We found that tested materials were safe in those conditions. I think that Non-Exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Selfadhesive Rubberized Asphalt sheet is available to concrete structure.

  • PDF