Examination on Effect of Horizontal Vent Position on Fire Phenomena in Enclosure

구획실 화재 현상에 대한 수평 개구부 위치의 영향 검토

  • Published : 2022.04.20

Abstract

In the present study, the effect of horizontal vent position on fire phenomena in the enclosure with vertical and horizontal vents was examined using numerical simulation. Case 1 indicates the condition that the horizontal vent is in the center of the ceiling. Case 3 indicates the condition that the horizontal vent is far away from the vertical vent. Case 2 indicates the condition that the horizontal vent is installed between Case 1 and Case 3. The temperature distribution, smoke layer temperature, velocity distribution, and mass flow rate of horizontal vent flow were analyzed. In Case 2, the temperatures were lowest and the mass flow rate through the horizontal vent was largest. This is because the flame is inclined by the inflow through the vertical vent. Hence, to determine the proper horizontal vent location for the high smoke ventilation performance, the inflow through the vertical vent and its effect on flame behavior should be considered.

Keywords

Acknowledgement

본 논문은 소방청 "국민소방협력 초기대응 현장지원 기술개발사업(20016433)"의 지원을 받아 작성되었음.