A Study on the Smoke Compartment Standards Analysis of Domestic and Abroad for Prevention of Smoke Spread in Large-Scale Buildings -Focused on the Analysis of Goyang Bus Terminal Fire Incident-

대형공간의 연기확산 방지를 위한 국내·외 방연구획 기준 분석에 관한 연구 -고양시 터미널 화재 사례 분석을 중심으로-

  • 김혜원 (호서대학교 소방방재학과) ;
  • 한지우 (호서대학교 소방방재학과) ;
  • 이병흔 (호서대학교 소방방재학과) ;
  • 진승현 (호서대학교 소방방재학과) ;
  • 권영진 (호서대학교 소방방재학과)
  • Published : 2018.05.16

Abstract

In this study, it analyses the problems of the Fire Compartment in Goyang Bus Terminal. Based on analysed data, it is confirmed the necessity of the Smoke Compartment installation for Protecting the Smoke Spread in Large-Scale Buildings using of FDS(Fire Dynamics Simulation). In addition it suggest that the necessity of Smoke Compartment application method and Development of Design Guideline.

Keywords