• Title/Summary/Keyword: 열화상카메라

Search Result 254, Processing Time 0.03 seconds

Design of a Reflector for Infrared Camera (열화상 카메라용 반사경 설계)

  • Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.1
    • /
    • pp.97-104
    • /
    • 2014
  • Recently infrared cameras have been widely used to diagnosis degradation status of the power substitution system. At the place of high magnetic field, however, electronic parts of infrared camera take a place problem that is not reasonable working due to high magnetic field. In this paper, technique of design for reflector is proposed to perform degradation diagnosis without damage of infrared camera in a power substation system including the rectifier that is able to impact to the infrared camera by high magnetic field.

Development of Calibration Target for Infrared Thermal Imaging Camera (적외선 열화상 카메라용 캘리브레이션 타겟 개발)

  • Kim, Su Un;Choi, Man Yong;Park, Jeong Hak;Shin, Kwang Yong;Lee, Eui Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.248-253
    • /
    • 2014
  • Camera calibration is an indispensable process for improving measurement accuracy in industry fields such as machine vision. However, existing calibration cannot be applied to the calibration of mid-wave and long-wave infrared cameras. Recently, with the growing use of infrared thermal cameras that can measure defects from thermal properties, development of an applicable calibration target has become necessary. Thus, based on heat conduction analysis using finite element analysis, we developed a calibration target that can be used with both existing visible cameras and infrared thermal cameras, by implementing optimal design conditions, with consideration of factors such as thermal conductivity and emissivity, colors and materials. We performed comparative experiments on calibration target images from infrared thermal cameras and visible cameras. The results demonstrated the effectiveness of the proposed calibration target.

Development and Possibility Evaluation of Thermal Imaging Camera for Medical Monitoring of Body Temperature (열화상카메라 개발을 통한 의료용 체열진단 가능성 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.57-62
    • /
    • 2015
  • Recently, thermography camera have been using for body-temperature monitoring. We report on fabrication of prototype thermography camera using the chalcogenide-glass lens and the camera test by analysis of thermal image. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ with noise equivalent temperature difference(NETD) of 87.7mK. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.

Development of malfunction diagnostic robot in distribution line using the Infrared Thermal Imaging Camera, CCD Camera (열화상 카메라와 CCD 카메라를 이용한 배전선 고장진단 로봇개발)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.85-86
    • /
    • 2007
  • 본 논문은 기존에 사람의 인력이나 열화상 카메라에 의존하고 있는 배전선 기자재 점검을 사람대신 로봇이 점검 작업을 하고 기존의 열화상 카메라만 사용하는 점검 방법에 CCD 카메라를 추가로 사용하여 열화상 이미지와 실영상을 같이 획득하도록 하여 배전선 점검 작업의 안전성 확보와 고장진단의 결과 값들의 객관성 있고 정확한 데이터를 획득을 할 수 있도록 하였다. 그리고 로봇이 가공지선을 자율주행하면서 발생하는 포스트 간 이동, 가공지선 회피, 가공지선 다 분기와 같은 문제가 발생하게 되는데 이러한 문제점들은 센서 융합 방법을 사용하여 로봇이 가공지선을 원활하게 자율주행을 할 수 있도록 하였다. 그리고 배전선 기자재들의 자연적 현상 때문에 발생하는 기자재의 부식과 열화로 변하게 되는 기자재들의 온도를 열화상 카메라로 분석하여 배전선 기자재들의 불량 기준 온도를 초과하게 되면 열화상 이미지와 CCD 카메라의 실영상 이미지가 자동으로 캡쳐 되고 저장 될 수 있게 하였다. 이러한 모든 동작들은 로봇이 자율주행을 하면서 이루어진다.

  • PDF

Visibility of the Thermal Infrared Camera under Non-Visibility Environments (비가시 환경에서의 적외선 열화상 카메라의 가시도)

  • Cho, Jai Wan;Baik, Seong Hoon;Choi, Young Soo;Jeong, Kyung Min
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1315-1316
    • /
    • 2015
  • 본 논문에서는 원자력발전소 중대 사고를 모사한 비가시 환경에서 적외선 열화상카메라의 관측성능 (가시도)을 정량적으로 평가하고자 하였다. 이를 위해 세계기상기구의 가시도 정의를 이용하여 가시도를 측정하였으며, 측정된 가시도 조건에서 적외선 열화상카메라의 관측성능을 평가하였다.

  • PDF

A Study on Estimation of Submarine Groundwater Discharge Distribution area using IR camera and Field survey around Jeju island (열화상카메라와 현장조사를 이용한 제주 주변 해역의 해저 용천수 분포 지역 추정 연구)

  • Park, Jae-Moon;Kim, Dae-Hyun;Yang, Sung-Kee;Yoon, Hong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.8
    • /
    • pp.861-866
    • /
    • 2015
  • This study was aimed to detect area of Submaine Groundwater Discharged(: SGD) around Jeju island using by remote sensing. Sea Surface Temperature(SST) was identified using IR camera on Unmaned Aerial Vehicle(UAV) at Gimnyeong port in study area. Then SGD location was detected by comparing range of SGD temperature. Generally, range of SGD temperature is distributed 15 to 17 like underground water. The result, SGD location was detected by SST distribution of Gimnyeong port recorded by IR camera in the southwest of study area.

Study on the Effect of Emissivity for Estimation of the Surface Temperature from Drone-based Thermal Images (드론 열화상 화소값의 타겟 온도변환을 위한 방사율 영향 분석)

  • Jo, Hyeon Jeong;Lee, Jae Wang;Jung, Na Young;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.1
    • /
    • pp.41-49
    • /
    • 2022
  • Recently interests on the application of thermal cameras have increased with the advance of image analysis technology. Aside from a simple image acquisition, applications such as digital twin and thermal image management systems have gained popularity. To this end, we studied the effect of emissivity on the DN (Digital Number) value in the process of derivation of a relational expression for converting DN to an actual surface temperature. The DN value is a number representing the spectral band value of the thermal image, and is an important element constituting the thermal image data. However, the DN value is not a temperature value indicating the actual surface temperature, but a brightness value indicating high and low heat as brightness, and has a non-linear relationship with the actual surface temperature. The reliable relationship between DN and the actual surface temperature is critical for a thermal image processing. We tested the relationship between the actual surface temperature and the DN value of the thermal image, and then the radiation adjustment was performed to better estimate actual surface temperatures. As a result, the relation graph between the actual surface temperature and the DN value similarly show linear pattern with the relation graph between the radiation-controlled non-contact thermometer and the DN value. And the non-contact temperature after adjusting the emissivity was closer to the actual surface temperature than before adjusting the emissivity.

A Comparative Study on Moving Object Detection between Visual and Thermal Cameras (열화상과 가시광선 카메라 영상의 이동 객체 탐지에 대한 비교 연구)

  • Kim, Chungman;Moon, Chanki;Nam, Yunyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.548-550
    • /
    • 2015
  • 본 논문은 열화상 카메라와 가시광선 카메라를 사용하여 촬영한 영상에서 움직이는 객체에 대한 검출률을 비교한다. 각 카레라는 객체로부터 8m 떨어진 지점에 위치시켰으며, 촬영한 영상에 가우시안 필터만을 적용하여 객체를 검출하였다. 객체가 존재하는 구간에서 객체가 검출된 영상으로부터 검출률을 계산하였고, 두 개의 이동 물체로부터 얻은 영상에서 열화상 카메라와 가시광선 카메라에서 각각 98.6%와 55%의 검출률을 얻었다.

선박 스팀 배관 고장 진단과 예측을 위한 열화상 모니터링 시스템 개발

  • 임성래;최경열;박순호
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.11a
    • /
    • pp.111-113
    • /
    • 2023
  • 자율운항선박 기술개발사업 중 2세부(자율운항선박 핵심 기관시스템 성능 모니터링 및 고장예측 진단 기술 개발)과제에서 자율운항선박 핵심장비 중 증기 배관(Steam Pipe)의 모니터링 및 고장예측 시스템 중 열화상 카메라에 의한 증기 배관(Steam Pipe)을 브라우저에서 모니터링 하는 시스템을 연구 및 개발 목표로 한다.

  • PDF

Measurements of Temperature Distribution on Human Body Surface using Multi-Channel Skin Temperature Sensors (다채널 피부온 센서를 이용한 인체표면 온도분포의 측정)

  • 한화택;김민규;박명규;이성수
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.205-209
    • /
    • 2002
  • 인체의 피부온도는 쾌적성과 감성에 크게 영향을 미치며 의류의 개발이나 건축환경의 설계 등에 활용되고 있다. 단순히 몇몇 측정점에서의 피부온도 데이터가 아니라 인체표면에 걸친 온도분포를 파악함으로써 다양한 정보를 이용하여 보다 광범위한 응용분야에 활용될 수 있을 것이다. 현재 인체표면의 온도분포를 측정하기 위하여 대부분 적외선 열화상 카메라를 활용하고 있다 그러나 열화상 카메라는 서미스터 등을 이용한 피부온 센서에 비하여 온도분해능이 떨어지며 특히 의복내의 피부온을 측정하는 것이 불가능하고 노출된 인체표면에 대해서만 측정이 가능하다. 따라서 본 연구에서는 피부온 센서를 이용한 인체표면 온도분포 측정시스템을 개발하기 위하여 각 센서의 위치와 간격, 그리고 인체 곡면을 따라서 보간법에 따라 온도분포 결과에 미치는 영향을 파악하고 적외선 화상 결과와 비교하고자 한다.

  • PDF