Hydraulic Tests of Fuel Pump for 75-ton class Liquid Rocket Engines

75톤급 로켓엔진용 연료펌프의 수력성능시험

  • 김대진 (한국항공우주연구원 터보펌프팀) ;
  • 홍순삼 (한국항공우주연구원 터보펌프팀) ;
  • 최창호 (한국항공우주연구원 터보펌프팀) ;
  • 노준구 (한국항공우주연구원 터보펌프팀) ;
  • 김진한 (한국항공우주연구원 터보펌프팀)
  • Published : 2009.11.19

Abstract

A series of hydraulic tests of a fuel pump are performed using water at a room temperature. The pump is under development for 75-ton class liquid rocket engines of the open-loop gas generator type. According to the test results, the fuel pump satisfies its design requirement and its head and efficiency at the design flowrate are higher than the expected value by the computational analysis. Also, it is found that the pressure at the rear bearing outlet is higher than expected because the inlet of bypass pipe line is narrow. Furthermore, the flowrate of the secondary flow is estimated using the pressure difference of the elbow of the bypass pipe line.

연료펌프에 대한 수력성능시험을 상온의 물을 매질로 하여 실시하였다. 시험된 연료펌프는 개방형 가스발생기 방식의 75톤급 액체로켓엔진에 적용할 목적으로 개발 중에 있다. 시험 결과, 연료펌프는 설계요구조건을 만족하였으며, 설계 유량에서의 양정과 효율은 수치해석에서 추정된 값보다 높았다. 또한 후방 베어링의 출구 압력이 예상보다 높았는데 이는 바이패스 배관의 입구가 좁기 때문이었다. 그리고 바이패스 곡관부의 차압 측정으로 누설 유량을 유추할 수 있었다.

Keywords