New Fire Resistant Methods of RC Structures Using ECC

구조물의 내화공법에 대한 ECC 적용 가능성

  • Published : 2008.11.07

Abstract

Fire safety is one of the important factors to be examined when applying ECC to actual concrete structures. The purpose of this study is to confirm whether the fire resistance of ECC satisfies the fire resistant requirements in order to use the fire protection material in concrete structures. Employed temperature curve are HC and RABT criterion, which are severe in various criterion of fire temperature in concrete structures. The test results show that ECC did not undergo any deterioration of fire resistance nor cause explosive spalling, which had been anticipated due to the presence of organic fibers. With comparison of current concrete and fire-resistance materials, the experimental results of ECC shows the better fire resistance performance than the other.

화재에 대한 안전성 확보는 ECC 등과 같은 신소재를 실제 구조물에 적용 또는 실용화하기 위해필요한 중요한 요소 중 하나이다. 본 논문은 콘크리트 구조물에 있어서 내화층을 ECC로 사용하는 공법에 대하여, 이러한 ECC가 규준에서 요구하는 내화성능을 만족하는지 여부를 실험적으로 검토하기 위한 것이다. 이를 위하여 구조물의 화재 온도조건인 HC 및 RABT 화재온도이력곡선을 적용하여 실험을 수행하였다. 실험결과 ECC는 폭렬 및 화재상태에서의 모체콘크리트에 열화가 발생하지 않았다. 또한 기존 콘크리트 및 내화소재와의 상대 비교에 있어서도 ECC가 가장 우수한 내화성능을 보이고있음을 알 수 있었다.

Keywords