전치 가이드 베인 설치에 따른 열회수 보일러 입구 온도 최적화

NUMERICAL OPTIMIZATION OF TEMPERATURE DISTRIBUTION IN HRSG SYSTEM USING INLET GUIDE VANE

  • 이수윤 (홍익대학교 대학원 기계공학과) ;
  • 안준 (한국에너지기술연구원) ;
  • 신승원 (홍익대학교 기계시스템디자인공학과)
  • 발행 : 2008.03.26

초록

Diverging channel from gas burner exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW system. To improve the uniformity in velocity and temperature distribution of existing design(Case A and B) of 300 kW HRSG system, two additional test geometries have been chosen for the numerical simulation. At first, gas burner exit section has been centered to the inlet section of boiler(Case C) and uniformity has been improved considerably. Secondly, the diverging channel length can be further reduced for compact geometry with new guide vane design (Case D and E). Proposed design shows overall improvement in uniformity in velocity and temperature distribution compared to existing one.