An Experimental Study on the Insulation Property of Light-Weight Foamed Concrete according to Foaming Agent Type

기포제 종류에 따른 경량기포콘크리트의 단열특성에 관한 실험적 연구

  • 최훈국 (공주대학교 건축공학과 대학원) ;
  • 선정수 (공주대학교 건축공학과 대학원) ;
  • 이정구 (공주대학교 건축공학과 대학원) ;
  • 최덕진 (공주대학교 건축공학과 대학원) ;
  • 정지용 ((주)에이스 패널) ;
  • 김진만 (공주대학교 건축공학과)
  • Published : 2007.11.16

Abstract

Recently, use of light-weight panel is increasing in building. Styrofoam sandwich panel is inexpensive and it is excellent in insulation ability and constructability. But styrofoam of panel inside is low ignition point. Consequently, when panel is fired, it is occur in poisonous gas. On the other hand, light-weight foamed concrete is excellent in insulation ability, fire resistance due to inner pore. Properties of light-weight concrete is influenced by foaming agent type. Accordingly, this study investigate in insulation property of according to foaming agent type in order to using light-weight foamed concrete instead of styrofoam. As a results, Non-heating zone temperature of light-weight foamed concrete of using AP, FP are lower than light-weight foamed concrete of using AES. Light-weight foamed concrete of using AES, FP are satisfied with fire performance of two hours at foam ratio 50, 100. Light-weight foamed concrete of using AP is satisfied with fire performance of two hours at AP ratio 0.1, 0.15. Insulation property is better closed pore by made AP, FP than open pore by made AES.

Keywords