A Study on the Detection of Defective Motors by Using Maharanobis' Distance

마하라노비스 거리를 이용한 모터 불량품 검출 방법에 관한 연구

  • 장한기 (고등기술연구원 제품기술연구센터) ;
  • 홍석인 (고등기술연구원 제품기술연구센터) ;
  • 박성근 (AB&S(주)) ;
  • 구치욱 (대우일렉트로닉스)
  • Published : 2006.11.16

Abstract

In this paper, Maharanobis distance was used to distinguish defective motors from good motors. Maharanobis distance was calculated from the noise data of good motors and the test motor that were measured in 1/3 octave hand from 25 Hz to 20 kHz frequency range. The suggested method was applied to the detection of defective air-conditioner motors.