An Investigation of the Major Factors Relating to the Flow Fluctuation at a Natural Gas Metering Facility

천연가스 계량설비에서 발생하는 유량 헌팅 현상 원인 분석

  • 안승희 (한국가스공사 연구개발원 현장기술지원센타) ;
  • 허재영 (한국가스공사 연구개발원 현장기술지원센타) ;
  • 정종태 (한국가스공사 연구개발원 현장기술지원센타) ;
  • 신창훈 (한국가스공사 연구개발원 현장기술지원센타)
  • Published : 2005.12.01

Abstract

KOGAS(Korea Gas Corporation) has about a hundred of local stations to supply natural gas to the city gas companies and the power stations. As some severe flow fluctuation phenomena are observed in several governor stations, the investigation about the reasons and factors which are relating to flow fluctuation has been started. Some field surveys hav been carried out and experimental studies have been performed to find the fluctuation mechanism. As a result, it is found that the flow fluctuation is related with the length of straight pipe in front of the meter, the size of the header pipe and the variation of demand at the city gas company and the power station. Furthermore. it is also proved that both the length of the transmitter cable and the status of the coating of signal transmission cable do not affect flow fluctuation, but the measurement range of the differential pressure transmitter influences flow fluctuation. On the other hand, as the averaging the flow fluctuation is converged to less than 0.1 % in almost all of the cases, it is concluded that the quantity of flow fluctuation do not relates to metering accuracy directly.