CPT를 이용한 준설매립지반의 개량효과 평가에 관한 연구

A Study on the Ground Improvement Effective Evaluation of Reclaimed Land Using Cone Penetration Test

  • 김종국 (한국건설품질시험원 지반기술팀) ;
  • 채영수 (수원대학교 토목공학과) ;
  • 김명모 (서울대학교 지구환경시스템공학부)
  • 발행 : 2004.03.25

초록

In this study, the pilot tests on the reclaimed land were performed in order to find the suitable construction method with dynamic compaction Type I, Type II at different dynamic energy and hydraulic hammer compaction. The estimation of the compaction through the various pilot tests was performed by the CPT-qc, SPT-N and field density tests. As the result of the pilot tests, it shows that the dynamic compaction method is better than the hydraulic hammer compaction method in the effect of the ground improvement, especially dynamic compaction Type I is much superior to others. When it comes to method for measuring the intensity of the ground, the value of the cone penetration test-resistance(qc) is much suitable for the ground. Besides, the standards for the compaction control, which showed that over 10Mpa at 0 through 5meters in the upper layer and 7Mpa at 5 through 8meters in the lower layer in the CPT-qc, could be found without discrimination of the upper road and lower road on the reclaimed land. And it also found that the intensity of the reclaimed land gets back to the original status in about 10 through 15 days.

키워드