Analysis of Breaking Accident of FRP Insulator Rod installed in Dead Section

절연구간 조가선 FRP 절연봉의 절단사고 원인분석

  • 장동욱 (한국철도기술연구원 전기신호연구본부) ;
  • 이기원 (한국철도기술연구원 전기신호연구본부) ;
  • 김주락 (한국철도기술연구원 전기신호연구본부) ;
  • 박현준 (한국철도기술연구원 전기신호연구본부)
  • Published : 2003.07.10

Abstract

The accidnet of breaking insulator rod leads to inturruption of moving the subway. We investigate the analysis of analysis of breaking accident of FRP insulator rod installed in dead section for catenary feeding system. To analysis of accident reason, SEM is used to analysis microscopic struture on surface of cross section of broken FRP insulator rod. At the same time, we examine the chage of atomic amount on solace of accident insulator through EDX analysis. Also, the test for tensional breaking load is condoled to check the mechanical strength.