The Evaluation of Remaining Strength for Corroded Pipeline by Full Scale Burst Test

실제크기 배관의 파열시험을 통한 가스배관의 파괴거동 평가

  • 김영표 (한국가스공사 연구개발원) ;
  • 백종현 (한국가스공사 연구개발원) ;
  • 김우식 (한국가스공사 연구개발원)
  • Published : 2001.06.27

Abstract

The transmission pipeline industry spends many millions of dollars annually performing inline inspections, excavating sites of possible corrosion, and repairing or replacing damaged sections of pipe. New criteria for evaluation the integrity of corroded pipe have been developed in recent years to help in controlling these costs. These new criteria vary widely in their estimates of integrity and the most appropriate criterion for a given pipeline is not always clear. This paper presents an overview, comparison and evaluation of acceptability criteria for corrosion defects in pipelines. By full scale burst tests, this paper have assessed the relative accuracy of each of theses criteria in predicting failure and remaining strength. Many of the criteria appear to be excessively conservative and indicate that defects must be repaired when none is needed, based upon burst test data.

Keywords