Static pile load test and load trasfer measurement for large diameter piles.

대구경 말뚝정재하시험 및 하중전이 측정사례

  • 최용규 (경성대학교 건설·환경공학부)
  • Published : 2000.03.01

Abstract

Large diameter piles can be defined as piles with diameter of at least 0.76 m (2.5 ft). In bridge foundation, large diameter piles have been used as pier foundations and their use has been increased greatly. In this study, static pile load tests for large diameter piles peformed in Kwangan Grande Bridge construction site were introduced. Also, various sensor installation methods for several types of piles (that is, open-ended steel pipe pile, drilled shafts and socketed pipe piles), pipe axial load measuring method, load transfer analysis method and pile load test results (pile-head load - settlement curve, and pile axial load distribution curve along the pile depth) were introduced.

Keywords