The $SO_2$ effect on NOx removal by Corona Shower System

코로나 샤워 시스템을 이용한 NOx제거에서 $SO_2$의 영향

  • 박재윤 (경남대학교 전기공학과) ;
  • 김익균 (경남대학교 전기공학과) ;
  • 이재동 (경남대학교 전기공학과) ;
  • 김종달 (동명정보대학 전기과) ;
  • 이덕출 (인하대학교 전기공학과) ;
  • Published : 1998.07.20

Abstract

In this study, the $SO_2$ addition effect on NOx removal has been conducted from a combustion flue gases by the do corona discharge-activated radical shower systems. The simulated flue gases were consisted of NO-O_2-$N_2$, NO-$CO_2-N_2-O_2$ and $NO-SO_2-CO_2-Na-O_2$([NO]o:200ppm and $[SO_2]o$:800ppm). The injection gases used as radical source gases were $NH_3$-Ar-air. $SO_2$ and NOx removal efficiency and the other by-products were measured by Fourier Transform Infrared(FTIR) as well as $SO_2$. NOx and $NO_2$ gas detectors. By-product aerosol particles were also observed by Condensation Nucleation Particle Counter(CNPC) and SEM images after sampling. The results showed that asignificant aerosol Particle formation was observed during a removal operation in corona radical shower systems. The NOx removal efficiency significantly increased with increasing applied voltage and $NH_3$ molecule ratio. The $SO_2$ removal efficiency was not significantly effected by applied voltage and slightly increased with increasing $NH_3$ molecule ratio. The NOx removal efficiency for NO-$SO_2-CO_2-N_2-O_2$ was better than that for NO-$CO_2-N_2-O_2$.

Keywords