• Title/Summary/Keyword: zero-accident

Search Result 64, Processing Time 0.03 seconds

Optimum Construction Duration for Road Tunnel Excavation Works (도로터널 굴착공사의 적정공기 판단기준)

  • Kim, Ha-Na;Kim, Dae Young;Kim, Dae-Young;Jeong, Seong-Chun;Huh, Young-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.4
    • /
    • pp.59-64
    • /
    • 2018
  • Construction schedule acceleration due to unreasonable construction planning frequently leads to construction accidents. In order to avoid such inevitable acceleration and to ensure safety in construction sites, there is a need for objective standards to determine appropriate construction duration for each construction process earlier in the process. In order to achieve the goal, intensive experts interviews were firstly conducted to identify candidate drivers affecting construction schedule of road tunnel excavation works. Then, a total of 34 field data was collected from on-going sites to analyze. It was found that actual excavation length per one day on site is varied mostly by Rock Mass Rating(RMR) types from various statistical analyses. Therefore an one-way table of excavation length per a day by RMR types were presented in a form of percentile. The results will help industry experts determine the most appropriate construction schedule for the works, which eventually lead to a zero accident site in many ways.

Static and transient analyses of Advanced Power Reactor 1400 (APR1400) initial core using open-source nodal core simulator KOMODO

  • Alnaqbi, Jwaher;Hartanto, Donny;Alnuaimi, Reem;Imron, Muhammad;Gillette, Victor
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.764-769
    • /
    • 2022
  • The United Arab Emirates is currently building and operating four units of the APR-1400 developed by a South Korean vendor, Korea Electric Power Corporation (KEPCO). This paper attempts to perform APR-1400 reactor core analysis by using the well-known two-step method. The two-step method was applied to the APR-1400 first cycle using the open-source nodal diffusion code, KOMODO. In this study, the group constants were generated using CASMO-4 fuel transport lattice code. The simulation was performed in Hot Zero Power (HZP) at steady-state and transient conditions. Some typical parameters necessary for the Nuclear Design Report (NDR) were evaluated in this paper, such as effective neutron multiplication factor, control rod worth, and critical boron concentration for steady-state analysis. Other parameters such as reactivity insertion, power, and fuel temperature changes during the Reactivity Insertion Accident (RIA) simulation were evaluated as well. The results from KOMODO were verified using PARCS and SIMULATE-3 nodal core simulators. It was found that KOMODO gives an excellent agreement.

Analysis of Operation Characteristics of DC Circuit Breaker with Superconducting Current Limiting Element (초전도 전류제한소자를 적용한 DC 차단기의 동작 특성 분석)

  • Jung, Byung-Ik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1069-1074
    • /
    • 2020
  • Since DC has no zero point, an arc occurs when the DC circuit breaker performs a shutdown operation. In this case, a fatal accident may occur in the circuit breaker or in the grid, depending on the magnitude of the arc. Therefore, the shutdown performance and the reliability of the circuit breaker are important in the commercialization of HVDC. In this study, a superconducting LC circuit breaker was proposed to improve the performance and the reliability of the DC circuit breaker. The superconducting LC circuit breaker applied a superconducting coil to the inductor of the existing LC circuit breaker. Other than limiting the initial fault current, it also creates a stable zero point in the event of a fault current. To verify this, simulation was performed through EMTDC/PSCAD. Furthermore, the superconducting LC circuit breaker was compared with the LC circuit breaker with a normal coil. As a result, it was found that the LC circuit breaker with the superconducting coil limited the initial fault current further by approximately 12 kA compared to the LC circuit breaker with a normal coil. This reduced the arc extinguish time by approximately 0.16 sec, thereby decreasing the elctrical power burden on the circuit breaker.

A Development of System for Efficient Quantitative Risk Assessment on Natural Gas Supply Facilities (천연가스 공급시설에 대한 효율적 정량적 위험성 평가를 위한 시스템 구축과 적용)

  • Yoon, Ik-Keun;Oh, Shin-Kyu;Seo, Jae-Min;Lim, Dong-Yeon;Yoon, En-Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • While the natural gas supply industry has continuously been growing, its potential hazard has also risen since the natural gas facilities essentially require installations that carry highly flammable and pressurized gas close to the populated areas, posing a serious consequence of significant property damage as well as human casualties in the event of accident. Therefore Quantitative Risk Assessment (QAR) has been recognized as a appropriate method to reduce the risk as far as possible, considering the reality of unachievable zero-risk. However, it is hard to perform effective QRA on hundreds of gas facilities because of insufficient number of expert and long-term analysis. In this paper, we suggest a conceptual QRA system framework to support more efficient risk analysis in gas supply facilities. In this system, the experts make questionnaires and internal calculation formula needed in accident frequency/consequence analysis of the facility through pre-analysis on the point of analysis, called incident point, and general users locate the point on the map and input the value required by the questionnaire to obtain the risk. Ultimately, this is suggested based on the idea that the specialization is available in QRA analysis process and the validity of the system is verified through actual system construction and application.

Effective Customer Risk Management at the Nuclear Medicine Department: Risk Managemont MOT Development Application and Producing Public Relations Film (핵의학과 내에서의 효과적인 고객위험관리: 위험관리 응대 MOT 개발적용 및 홍보동영상 제작)

  • Ham, Jong-Hum;Hwang, Jae-Bong;Kim, Joon-Ho;Lee, Gui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.110-122
    • /
    • 2009
  • Purpose: Nowadays, A medical institution assesment could get more interest about a quality of medical services from many hospitals that developed the active activities for improving medical services. Also, there is an other additional issue which is the patients risk management. Uijeongbu ST. Mary's hospital Nuclear Medicine department has been changed many work process after PET-CT introduction and renovation of its place since 2008. Therefore, modified structure and the way of existing work process have contained risk factors. The purpose of this study would be the appropriate risk management process while imaging examination process, the removal risk factors and improved activities through the analysis risk factors. Materials and Methods: Nuclear Medicine department new process should analysis through many-sided, Firstly, make and trained risk management manual after then apply an actual work. Result analysis showed the number of risk accident occurrence that comparing the last year and after the improved activities. Secondly, producing risk management public relations film has been showed an applicable patient after then the customer service measurement checked for a hundred patient by questionnaire. Lastly, Risk factors were eliminated through the facilities participation improving activities which could change for the better risk factors. Results: The number of safety accident occurrence(medication error, fall and collision) were checked as zero after the improving activities both PET-CT and gamma camera examination. The results of questionnaire showed as follows; 74% marked as understanding of the test process and 81% checked "satisfaction" after the public relations film showing. The question "Did you consider about the risk factors?", both PET-CT and gamma camera checked as 94% and 89% respectively. Customer risk management could be accomplished effectively through the improving activities at the nuclear medicine department. Conclusions: The study would be an opportunity that spread risk factors were systematically showed and analyzied. Also, It showed the possibility of the minimized safety accident and its feedback, if application of the response manuel that could be a standard of radiology technician's work method to react safety accident. It was the more effective that visual material could be easy to approach as a methodology of risk factors. As far as I have concerned that It could help the safety and convenience through continuous and detailed activities that offer to patients.

  • PDF

Reformation of Environmental Regulation through introduction of the Zero Liquid Discharge System (무방류시스템 도입에 따른 환경규제효율화 방안)

  • Choi, Ji-Yong
    • Journal of Environmental Policy
    • /
    • v.2 no.1
    • /
    • pp.31-49
    • /
    • 2003
  • It is difficult to examine the causal relation of pollution damages because the time gap between pollution cause and effect is large and new pollutants are continuously being produced. Their many environmental effects are not promptly studied. As both the study of causal relation about pollution and the pollutant treatment are becoming highly advanced by the development of science and environmental technology, both the economy and balance on environmental regulation may be discussed. It is reasonable to decide environmental policy in consideration of close relation between both the generation and resolution of environmental problems and of technological developments because environmental problems are related to complicated social problems and scientific technologies. First item in policy decision about environmental control and management is preferentially to consider the way of prevention. It is necessary to prevent pollution by regulating the installment of environmental pollution facility into the environmentally sensitive areas, like water supply source and to regulate land utilization as a method to achieve pollution prevention. Second is a consideration of environmental technology development. This is a solution which can accomplish the development of environmental technology and the reinforcement of economic competition. Third is the coexistence of environment and economy. It is necessary to consider economy in connection with environmental problems and environment in economic problem. Then, we can enjoy a healthy life as well as economic affluence. Fourth is the enlargement of environmental management means. Environmental management means must be diversified because environmental cause and effect are varied. For Improving the land use regulation system, it is necessary to consider both land use regulation status and pollutant toxicity with the development of environmental technology. Land use must be approached by classifying land to 3 levels; water source protection zone and water front zone, special zone 1 and 2, rancus and other zones. Land regulation policy to prevent any accident in water source protection zone, waterfront zone, and special zone must be continuously upgraded. However, economical consideration in other zones is required by the development of environmental technology.

  • PDF

Evaluation of Direct Vessel Injection Design With Pressurized Thermal Shock Analysis (가압 열충격해석에 의한 직접용기주입 설계의 평가)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.86-97
    • /
    • 1992
  • The purpose of this paper is to evaluate the direct vessel injection design from a pressurized thermal shock(PTS) viewpoint for the Combustion Engineering System 80+ A break of the main steam line from zero power and a 0.05 ft$^2$small break loss-of-coolant accident (LOCA) from full power were selected as the potential PTS events. In order to investigate the stratification effects in the reactor downcomer region, the fluid mixing analysis was performed using the COMMIX-IB code for steam line break and using the REMIX code for 0.05 ft$^2$small break LOCA. The stress distributions within the reactor vessel walls experiencing the pressure and the temperature transients were calculated using the OCA-P code for both events. The results of the analysis showed that a small break LOCA without decay heat presented the greatest challenge to the vessel, however, there is no crack initiation through end-of-life of the vessel with consideration of decay heat.

  • PDF

Voltage Control of Synchronous Generator for Ships using a PMG Type Digital Automatic Voltage Regulator (PMG Type 디지털 AVR을 이용한 선박용 동기발전기 출력전압제어)

  • Yu, Dong-Hwan;Park, Sang-Hoon;Won, Chung-Yuen;Yu, Jae-Sung;Lee, Sang-Seuk;Ahn, Sung-Joon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.38-45
    • /
    • 2009
  • To get the constant output, synchronous generator field excitation is controlled by AVR(Automatic Voltage Regulator). Most of ships generator AVR uses the thyristor phase controlled rectifier. However this rectifier is difficult to realize that the fast control system because its control period is slower than MOSFET and IGBT type converter. Therefore, this paper deals with PMG(Permanent Magnet Generator) type digital AVR using MOSFET switch for ships synchronous generator. The composition of this digital AVR is very simple, the generator is under the short circuit accident, the output voltage becomes zero state and AVR can not operate. Thus generator is required to add CBC(Current Boosting Circuit) in an excitation circuit to flow output current. The performance of the proposed system is evaluated on a 10[kVA] experimental prototype circuit in place of real ships generator.

Clinical Analysis of the Arterial Bypass Surgery for Chronic Ischemia of the Lower Extremities (하지 만성 허혈에 대한 동맥 우회술의 임상적 고찰)

  • 안정태
    • Journal of Chest Surgery
    • /
    • v.28 no.7
    • /
    • pp.678-683
    • /
    • 1995
  • Arterial bypass for the chronic ischemia of the lower extremities underlying atherosclerotic obliterans has been performed with a number of alternative conduits from 1941 by Kunlin. It is indicated for the limb salvage of patients with threatened limb loss despite of several controversies in surgical treatment of atherosclerotic obliterans. From March 1991 to January 1995, 26 arterial bypasses were performed in 23 patients with the chronic ischemia of the lower extremities in our hospital. Their mean follow up period is 18.9 months ranging from 4 months to 44 months. Mean age is 60.9 years ranging 47 years to 76 years and the most prevalent incidence is the 6th decade. 21 patients are male and 2 patients are female. 19 of 23 patients are smokers. Clinical classifications by Fontaine are class II[21.7% , class III[34.8% and class IV[43.5% .Diabetes mellitus[47.8% , hypertension[43.5% , hyperlipid-emia[26% , tuberculosis[21.7% , cerebrovascular accident[13.0% and cardiac diseases[8.7% are associated. Aorto-single femoral bypass in 4 cases, aorto-bifemoral bypass in 5 cases, aortofemoral & femoropopliteal bypass in 2 cases, femoropopliteal bypass in 10 cases, popliteotibial bypass in 3 cases, femoropedal bypass[composite graft bypass in 2 cases were surgically approached. There are complicated early thrombosis in 4 cases those are required immediately reoperation, wound infection in 3 cases, hematoma in 3 cases, and so on. Postoperative complication rate is 53.8%.Postoperative patency rates are 84.6% at 6 months, 75.0% at 1 year, 70.0% at 2 years and 66.7% at 3 years. We usually used 6 mm & 8 mm graft for bypass, and the rate of thrombosis formation is 28.6%[2/7 in 6 mm graft and 12.5%[2/16 in 8 mm separately. In according to the graft materials, the rate of thrombosis formation is higher in the group using artificial graft than in that using autologous saphenous vein[16.6% vs 12.5% . Limb salvage rate is 76.9%. Postoperative mortality rate is zero %.

  • PDF

Development of Performance Indicators Based on Balanced Score Card for School Food Service Facilities (균형성과표(BSC)개념을 적응한 학교급식 운영성과 측정지표 개발)

  • Kwak, Tong-Kyung;Chang, Hye-Ja;Song, Ji-Yong
    • Korean Journal of Community Nutrition
    • /
    • v.10 no.6
    • /
    • pp.905-919
    • /
    • 2005
  • This study raised the necessity of developing performance indicators for measuring the management efficiency and effectiveness of school food service, and as a means of helping its implementation, a balanced score card (BSC) approach developed by Norton and Kaplan was adopted. This study established BSC in seven phases through literature: Phase 1 Defining a school food service and the scope of working activities, Phase 2 Establishing the vision of a school food service, Phase 3 Setting strategic goals, Phase 4 Identifying critical success factors (CSFs), Phase 5 Developing Key Performance Indicators (KPIs), Phase 6 Extracting cause and effect relationship, and Phase 7 Completing a preliminary BSC. The preliminary BSC was fumed into a survey, which was administered to food service related people working at the Office of Education and School Food Service including 16 offices,209 dietitians, 48 school administrators both from self-operated and contract-managed, and 9 experts in areas related to school food service. They were asked questions about strategies from 4 different perspectives,12 CSFs, 39 KPls, and the cause and effect relationships among them. As a result, among the CSFs based on 4 different perspectives, all factors other than ' zero sum on profit/loss ' from the financial perspective turned out to be valid. In terms of KPIs, manufacturing cost percentages, casualty loss count/reduction rates, school foodervice participation rates, and sales goal achievement rates were found to be valid from the financial perspective, while student satisfaction index, faculty satisfaction index, leftover ratio, nutrition educational performance count, index of evaluating nutrition education, customer claim count/reduction rate, handling customer claim count/reduction rate, and parent satisfaction index were found to be valid from the customers' perspective. Besides, nutritional requirement sufficient ratio, nutritional management score, food poisoning outbreak count, employee safety accident count, sanitary inspection assessment index, meals per labor hour (productivity index), computerization ratio, operational management index, and purchase management assessment index were also found to be valid from the perspective of internal business processes. From the perspective of innovation and learning, employee turnover ratio/rate of absenteeism, annual education and training count, employee satisfaction index, human resource management assessment index, annual menu-related customer feedback, food service information index for employees and parents/schools were also found to be valid. The significance of this study is to present indices for measuring overall performance of school lunch food service operations without putting any limitation on types of school food service management, and to help correctly assess the contribution of the current types of school food service management to schools and students. (Korean J Community Nutrition 10(6) : $905\∼919$, 2005)