• 제목/요약/키워드: xenon

검색결과 282건 처리시간 0.024초

Design Considerations on the Standby Cooling System for the integrity of the CNS-IPA

  • Choi, Jungwoon;Kim, Young-ki
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.104-104
    • /
    • 2015
  • Due to the demand of the cold neutron flux in the neutron science and beam utilization technology, the cold neutron source (CNS) has been constructed and operating in the nuclear research reactor all over the world. The majority of the heat load removal scheme in the CNS is two-phase thermosiphon using the liquid hydrogen as a moderator. The CNS moderates thermal neutrons through a cryogenic moderator, liquid hydrogen, into cold neutrons with the generation of the nuclear heat load. The liquid hydrogen in a moderator cell is evaporated for the removal of the generated heat load from the neutron moderation and flows upward into a heat exchanger, where the hydrogen gas is liquefied by the cryogenic helium gas supplied from a helium refrigeration system. The liquefied hydrogen flows down to the moderator cell. To keep the required liquid hydrogen stable in the moderator cell, the CNS consists of an in-pool assembly (IPA) connected with the hydrogen system to handle the required hydrogen gas, the vacuum system to create the thermal insulation, and the helium refrigeration system to provide the cooling capacity. If one of systems is running out of order, the operating research reactor shall be tripped because the integrity of the CNS-IPA is not secured under the full power operation of the reactor. To prevent unscheduled reactor shutdown during a long time because the research reactor has been operating with the multi-purposes, the introduction of the standby cooling system (STS) can be a solution. In this presentation, the design considerations are considered how to design the STS satisfied with the following objectives: (a) to keep the moderator cell less than 350 K during the full power operation of the reactor under loss of the vacuum, loss of the cooling power, loss of common electrical power, or loss of instrument air cases; (b) to circulate smoothly helium gas in the STS circulation loop; (c) to re-start-up the reactor within 1 hour after its trip to avoid the Xenon build-up because more than certain concentration of Xenon makes that the reactor cannot start-up again; (d) to minimize the possibility of the hydrogen-oxygen reaction in the hydrogen boundary.

  • PDF

재귀반사시트의 Solar UV를 적용한 수명예측에 관한 연구 (A Study of Lifetime Prediction by Applying Solar UV Program of Retro-reflection Sheet)

  • 김창환;한진욱;김태진;김군옥
    • 공업화학
    • /
    • 제28권1호
    • /
    • pp.35-41
    • /
    • 2017
  • 외부에 노출된 재료는 자외선, 열, 온도, 습도 등의 다양한 환경 인자에 의해 성능저하가 일어나게 되며, 열화속도 및 사용수명에 대한 예측은 매우 중요한 문제이다. 본 연구에서는 가장 많이 사용되고 있는 색상 중 흰색, 초록색 재귀반사시트를 가지고 미국 아리조나, 인도 첸나이, 프랑스 세너리, 한국 서산 등 4개 지역에서 옥외폭로시험 및 제논아크촉진시험을 통하여 재귀반사시트 반사성능의 변화율을 측정하였다. 서산지역 및 제논아크 촉진시험을 통하여 얻어진 반사성능 값을 통해 회귀분석을 이용하여 가속계수를 구하였다. 또한, solar uv 프로그램을 이용하여 다양한 기후지역별 가속계수를 구할 수 있었으며, 그 결과 서산지역을 기준으로 프랑스 세너리 1.04배, 미국 아리조나 1.82배, 인도 첸나이 1.92배의 가속계수를 확인할 수 있었다.

DESIGN OF A LOAD FOLLOWING CONTROLLER FOR APR+ NUCLEAR PLANTS

  • Lee, Sim-Won;Kim, Jae-Hwan;Na, Man-Gyun;Kim, Dong-Su;Yu, Keuk-Jong;Kim, Han-Gon
    • Nuclear Engineering and Technology
    • /
    • 제44권4호
    • /
    • pp.369-378
    • /
    • 2012
  • A load-following operation in APR+ nuclear plants is necessary to reduce the need to adjust the boric acid concentration and to efficiently control the control rods for flexible operation. In particular, a disproportion in the axial flux distribution, which is normally caused by a load-following operation in a reactor core, causes xenon oscillation because the absorption cross-section of xenon is extremely large and its effects in a reactor are delayed by the iodine precursor. A model predictive control (MPC) method was used to design an automatic load-following controller for the integrated thermal power level and axial shape index (ASI) control for APR+ nuclear plants. Some tracking controllers employ the current tracking command only. On the other hand, the MPC can achieve better tracking performance because it considers future commands in addition to the current tracking command. The basic concept of the MPC is to solve an optimization problem for generating finite future control inputs at the current time and to implement as the current control input only the first control input among the solutions of the finite time steps. At the next time step, the procedure to solve the optimization problem is then repeated. The support vector regression (SVR) model that is used widely for function approximation problems is used to predict the future outputs based on previous inputs and outputs. In addition, a genetic algorithm is employed to minimize the objective function of a MPC control algorithm with multiple constraints. The power level and ASI are controlled by regulating the control banks and part-strength control banks together with an automatic adjustment of the boric acid concentration. The 3-dimensional MASTER code, which models APR+ nuclear plants, is interfaced to the proposed controller to confirm the performance of the controlling reactor power level and ASI. Numerical simulations showed that the proposed controller exhibits very fast tracking responses.

레이저 흡수 분광법을 이용한 He-Ne-Xe 상종가스의 외부전곡 램프의 $1s_4$ 공명준위와 $1s_5$ 준안정준위의 제논 원자 밀도에 대한 연구 (Laser absorption spectroscopy of ternary gas mixture of He-Ne-Xe in External Electrode Fluorescent Lamp (EEFL))

  • 정세훈;오필용;이준호;조광섭;최은하
    • 한국진공학회지
    • /
    • 제15권6호
    • /
    • pp.576-580
    • /
    • 2006
  • 본 논문에서는 수은 램프를 대체하기 위하여 제논 기체를 사용한 무수은 램프를 제작하여 제논 여기종 밀도에 대한 연구를 진행하였다. 진공자외선을 방사할 수 있는 $1s_4$ 공명준위의 제논 원자 밀도와 $1s_5$ 준안정준위의 제논 원자 밀도를 레이저 흡수 분광법을 사용하여 다양한 기체조건 및 방전전류에 따라서 측정하였다. 우리는 주어진 압력에서 방전전류에 따른 $1s_4$ 공명준위의 제논 원자 밀도와 $1s_5$ 준안정준위의 제논 원자 밀도를 측정하였으며 이러한 기본적인 방전 특성의 이해는 EEFL뿐만 아니라 플라스마 디스플레이에서도 발광 효율을 높이는데 매우 큰 기여를 할 것이다.

Spectra of Optical-field Ionized Gases by a Femtosecond Ti:Sapphire Laser

  • Mock, Tomas;Shin, Hyun-Joon;Cha, Yong-Ho;Lee, Dong-Gun;Hong, Kyung-Han;Nam, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • 제2권2호
    • /
    • pp.50-53
    • /
    • 1998
  • We report on the spectroscopic investigation of optical-field ionized plasmas in the soft X-ray spectral region. The experiment was carried out by focusing pulses of the high-power Ti:Sapphire laser with an energy of ~ 40 mJ and time duration of ~30 fs into a gas jet of krypton, xenon, and argon from a pulsed nozzle. Strong soft X-ray emission on lines from ionic stages of $Kr^{7+} , Kr^{8+} , Xe^{7+} , Ar^{7+} , and Ar^{8+}$ is reported. The experimental result was found to be in good agreement with theoretical prediction.

Cellulose의 광분해에 관한 연구(II) - 광조사된 면섬유의 화학적 성질을 중심으로 - (Photodegradation of Cellulosics(Part II) - Chemical Properties of Irradiated Cotton -)

  • 전경숙
    • 한국의류학회지
    • /
    • 제18권1호
    • /
    • pp.15-22
    • /
    • 1994
  • 본 연구에서는 면시험포와 cellophane film을 이용하여 xenon arc lamp 를 사용한 인공기후조 안에서 광선의 파장에 따른 강도의 변화와 변색을 조사하였다. Pyrex와 quartz filter를 사용하여 광선의 파장이 섬유의 성질을 변화시키는 중요한 요인임을 밝히고 first-order kinetic model을 사용하여 반응속도를 측정하였다. 또 면섬유의 황변현상을 화학적으로분석하여 파장이 긴 자외선과 가시광선의 영역에서는 황변과 동시에 표백효과가 있음을 알게 되었고 그 속도를 측정하였다. 세가지의 중요한 말단기분석을 통해 carbonyl기의 양이 제일 많고 carboxyl기와 peroxide기도 존재함을 분석하였고 또 이들의 양은 온도와 습도에 따라 변화하는 것으로 나타났다 Cellulose chain의 중합도를 측정하고 이를 cellulose bond scission과 연결시켜서 중합도와 섬유의 강도저하와의 관계를 연구하였다.

  • PDF

HIGH BURNUP CHANGES IN UO2 FUELS IRRADIATED UP TO 83 GWD/T IN M5(R) CLADDINGS

  • Noirot, J.;Aubrun, I.;Desgranges, L.;Hanifi, K.;Lamontagne, J.;Pasquet, B.;Valot, C.;Blanpain, P.;Cognon, H.
    • Nuclear Engineering and Technology
    • /
    • 제41권2호
    • /
    • pp.155-162
    • /
    • 2009
  • Since the 90's, EDF and AREVA-NP have irradiated, up to very high burnups, lead assemblies housing $M5^{(R)}$ cladded fuels. Post-irradiation examination of high burnup $UO_2$ pellets show an increase in the fission-gas release rate, an increase in fuel swelling, and formation of fission-gas bubbles throughout the pellets. Xenon abundances were quantified, and phenomena leading to this bubble formation were identified. All examinations provided valuable data on the complex state of the fuel during irradiation. They show the good behavior of these fuels, exhibiting various microstructures at very high burnups, none of which is likely to lead to problems during irradiation.

초기화재 감지를 위한 정밀한 연기 입자 감지 장치 개발 (Development of a precision smoke particle detector to sense a fire in early state)

  • 김희식;김영재;이호재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1734-1737
    • /
    • 1997
  • The conventional fire detection devices are operated after a processed fire phase, which are sensing only a high density of somke level or high temperature heat. They are not so precision to detect a fire in the early phase to protect the facility form the fire. We need to develope a new high precision smoke detection system to keep expensive industrial facilities most reliably form fire. A new optical precision smoke detection system was developed. It monitors very low level density of smoke particles in the air. It is operated continously through many years without a stop or any malfunction. The developed precision smoke detection system will be installed in important industrial facilities, such as power plants, underground common tunnel, main control rooms, computer rooms etc.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

호장근 추출액에 의한 염색성(Ⅱ) - 호장근 추출액의 자외 · 가시부 분광 특성 - (The Dyeing Properties of Korean Knotweed Extract(Ⅱ) - The UV-visible Spectrophotometric Characteristics of Korean Knotweed Extracts -)

  • 김미숙;최석철
    • 한국염색가공학회지
    • /
    • 제13권5호
    • /
    • pp.10-10
    • /
    • 2001
  • The Purpose of this study was to investigate spectrophotometric characteristics of Korean knotweed extracts. The properties were evaluated by it′s extracting solvent, effect of metallic ion, variations of pH values and effect of light exposure. The results were as following; The highest absorbance was found in methanol extract of Korean knotweed, while the lowest absorbance was carbon tetrachloride extract. The UV-vis. spectra of Korean knotweed colors in several solvents showed hypsochromic shift of n-π/sup */ transition with the polarity of solvent. Absorbance and peak of UV-vis. spectra of Korean knotweed colors became lower and broader by addition of metallic ion. The light stability in irradiation with xenon ]amp of the color solution with Cu were higher than those of Al and Fe. The UV-vis. spectra of Korean knotweed extracts in various pH values showed bathochromic shift under alkaline condition, and their peaks disappeared after 5 hours exposure.