• 제목/요약/키워드: x-ray noise

검색결과 261건 처리시간 0.027초

Unveiling the direct conversion X-ray sensing potential of Brucinium benzilate and N-acetylglcyine

  • T. Prakash;C. Karnan;N. Kanagathara;R.R. Karthieka;B.S. Ajith Kumar;M. Prabhaharan
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2190-2194
    • /
    • 2024
  • The study investigates the dose-dependent direct X-ray sensing characteristics of Brucinium benzilate (BB) and N-acetylglycine (NAG) organic crystals. BB and NAG were prepared as a slurry and deposited as a thick film on a patterned metal electrode. The X-ray induced photocurrent response was examined for various exposure doses using an intraoral pulsed 70 keV X-ray machine connected to a source meter. Subsequently, the morphological properties and thickness of the thick films were analyzed using scanning electron microscopy (SEM). At a photon energy of 70 keV, the attenuation coefficient values for NAG and BB crystals were determined to be approximately 0.181 and 0.178 cm2/g, respectively. The X-ray stopping power of the crystals was measured using a suniray-2 X-ray imaging system. To evaluate the responsiveness of the sensors, the photocurrent sensitivity and noise equivalent dose rate (NED) were calculated for both thick films. The findings demonstrated a noteworthy capability of sensing low doses (mGy), thereby suggesting the potential application of these organic materials in X-ray sensor development.

비정질 셀레늄층과 비정질 실리콘TFT배열을 사용하는 디지털 X-선 검출기의 영상특성 평가 (Image Quality Evaluation of Digital X-Ray Detector Using Amorphous Selenium Layer and Amorphous Silicon TFT Array)

  • 김창원;윤정기;김종효
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.219-226
    • /
    • 2008
  • 이 연구에서는 저자들이 개발한 비정질 셀레늄층과 비정질 실리콘TFT배열을 사용하는 직접방식 디지털 X-선 영상 검출기에 대해 IEC (international electrotechnical commission)와 같은 국제표준으로 권고된 측정방법에 따라 특성을 평가하였다. 영상 성능 묘사에 사용되는 측정은 응답특성(response characteristic), 변조전달함수(MTF, modulation transfer function), 잡음전력스펙트럼(NPS, noise power spectrum), 양자검출효율(DQE, detective quantum efficiency), 양자제한 성능을 포함하고 있다. 영상특성평가 결과, 개발된 검출기의 DQE 값은 최저주파수와 최고주파수에서 각각 40%와 25%이었다. 해외 타사의 제품과 비교해서도 우월한 값을 나타내었다. 또한 MTF는 간접방식 DR, CR과 비교하면 매우 우월한 성능을 보이고 있다. 또한 양자 제한된 특성을 평가한 결과, 0.023 mR 이하에서만 제한된 특성을 보여 일반촬영용도로서 적합성을 확인할 수 있었다.

  • PDF

Novel Structure of 21.6 inch a-Si:H TFT Array for the Direct X-ray Detector

  • Kim, Jong-Sung;Joo, In-Su;Choo, Kyo-Seop;Park, June-Ho;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.13-14
    • /
    • 2000
  • 21.6" a-Si:H TFT array for direct conversion X-ray detector with 2480 by 3072 pixel is successfully developed. To obtain good X-ray image quality, novel structure, storage on BCB structure, is proposed. The structure reduces the parasitic capacitance of data line, one of the main sources of signal noise. Also, the structure shows higher failure resistance against defects than that of the old design.

  • PDF

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • 나길주;백수웅;양현훈;박계춘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

X-ray 후방산란 기술을 이용한 항공기용 복합재료의 다중 층간 박리 평가 (Assessment of Multiple Delamination in Laminated Composites for Aircrafts using X-ray Backscattering)

  • 김노유
    • 비파괴검사학회지
    • /
    • 제30권1호
    • /
    • pp.46-53
    • /
    • 2010
  • 항공기용 복합재료 내부 여러 층에서 발생하는 박리를 정량적으로 평가하기 위한 X-ray 후방산란 검사장치를 개발하였다. 복합재료 두께방향으로의 역산란 밀도변화로부터 층간 박리를 검사하는 슬릿 방식의 카메라와 컴퓨터로 제어되는 X-ray 선원, 그리고 센서로 구성되는 X-ray 후방산란장치를 제작하여 그 성능을 충격하중에 의해 만들어진 인공결함시편을 이용해 검증하였다. 결함평가를 위해 복합재료내 산란장의 크기를 이론적으로 계산하는 수학적 해석 모델을 볼츠만 방정식을 이용하여 제안하였으며 적응필터 알고리즘을 사용하여 산란 노이즈를 최소화 하였다. 다중 박리 결함을 X-ray 후방산란장치를 통해 효과적으로 검출하였으며, 박리 위치와 박리 상태를 모두 정확하게 검사할 수 있음을 실험을 통해 확인하였다.

Fuzzy Logic Systems을 이용한 X-선 영상의 진단평가 (Diagonstic Evaluation of X-Ray Imaging using Fuzzy Logic Systems)

  • 이용구
    • 전자공학회논문지 IE
    • /
    • 제46권3호
    • /
    • pp.62-67
    • /
    • 2009
  • 본 논문에서는 퍼지논리시스템을 이용하여 ROC 곡선을 설계하였다. ROC 곡선은 진단평가를 위하여 이용되고, ROC 곡선을 평가하는 진단자는 초보 진단자를 선정하였다. 학습을 통한 ROC 곡선에 관한 진단능력을 평가하기 위하여 흉부 X-선 사진이 사용되었다. 진단을 위해 잡음과 신호(병변)을 갖는 X-선 필름을 사용하였다. 남성과 여성 간의 진단능력의 차이에 관하여 나타난 결과는 여성보다 남성이 우세한 것으로 나타났으나 그 차이는 작은 것으로 나타났다.

An Enhanced Algorithm for an Optimal High-Frequency Emphasis Filter Based on Fuzzy Logic for Chest X-Ray Images

  • Shin, Choong-Ho;Lee, Jung-Jai;Jung, Chai-Yeoung
    • Journal of information and communication convergence engineering
    • /
    • 제13권4호
    • /
    • pp.264-269
    • /
    • 2015
  • The chest X-ray image cannot be focused in the same manner that optical lenses are and the resultant image generally tends to be slightly blurred. Therefore, the methods to improve the quality of chest X-ray image have been studied. In this paper, the inherent noises of the input images are suppressed by adding the Laplacian image to the original. First, the chest X-ray image using an Gaussian high pass filter and an optimal high frequency emphasis filter has shown improvements in the edges and contrast of flat areas. Second, using fuzzy logic_histogram equalization, each pixel of the chest X-ray image shows the normal distribution of intensities that are not overexposed. As a result, the proposed method has shown the enhanced edge and contrast of the images with the noise canceling effect.

공간 적응적 임계값 설정을 통한 X-ray 영상의 잡음 제거 (Noise Reduction of X-ray Image by Spatially Adaptive Thresholding)

  • 유주완;이종민;김회율
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2005년도 가을 학술발표논문집 Vol.32 No.2 (2)
    • /
    • pp.934-936
    • /
    • 2005
  • 본 논문에서는 피라미드 계층간에 나타나는 잡음 신호의 특성을 바탕으로 라플라시안 피라미드를 이용한 X-ray 영상의 잡음 제거 방법을 제안한다. 제안하는 방법은 잡음 제거를 위해 X-ray 영상 신호의 지역적 표준 편차와 신호의 영역적 특징을 이용하였다. 지역적 표준 편차는 영상의 경계선 정도와 비례하는 특징을 가지기 때문에 지역적 표준 편차를 이용하여 경계 정보의 손실을 막았다. 또한 라플라시안 피라미드의 각 계층에 잡음 신호가 좁은 면적을 가지며 분포되는 영역적 특징을 이용하여 평평한 지역에서 잡음 신호의 제거 성능을 높였다. X-ray영상 및 잡음이 첨가된 표준 영상에 대한 실험을 통해 제안된 방법이 경계 정보의 유지와 잡음 제거에서 기존의 방법보다 향상된 성능을 보임을 확인하였다.

  • PDF

The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging

  • Lee, Jeonghee;Lim, Chang Hwy;Park, Jong-Won;Kim, Ik-Hyun;Moon, Myung Kook;Lim, Yong-Kon
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.197-204
    • /
    • 2017
  • Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners. Materials and Methods: We evaluated the characteristics of the signal and noise according to changes in the grid ratio and the material of the anti-scatter grid in an X-ray image detector using MCNP6. The grid was composed of iron, lead, or tungsten, and the grid ratio was set to 2.5, 12.5, 25, or 37.5. X-ray spectrum sources for simulation were generated by 6- and 9-MeV electron impacts on the tungsten target using MCNP6. The object in the simulation was designed using metallic material of various thicknesses inside the steel container. Using the results of the computational simulation, we calculated the change in the scatter-to-primary ratio and the signal-to-noise ratio improvement factor according to the grid ratio and the grid material, respectively. Results and Discussion: Changing the grid ratios of the anti-scatter grid and the grid material decreased the scatter linearly, affecting the signal-to-noise ratio. Conclusion: The grid ratio and material of the anti-scatter grid affected the response characteristics of a container scanner using high-energy X-rays, but to a minimal extent; thus, it may not be practically effective to incorporate anti-scatter grids into container scanners.

잡음이 있는 X선 프로젝션에 적합한 웨이블렛 기반 영상재구성 (Wavelet based Image Reconstruction specific to Noisy X-ray Projections)

  • 이남용;문종익
    • 융합신호처리학회논문지
    • /
    • 제7권4호
    • /
    • pp.169-177
    • /
    • 2006
  • 이 논문의 목적은 X선의 감쇠를 이용한 측정에서 발생하는 여러 종류의 잡음을 효과적으로 제거하는데 적합한 영상재구성 방법을 제안하는 것이다. 구체적으로, X선의 방출기와 검출기의 필연적인 기계적 오류에 의해 발생하는 원형모양 오류와 전반적인 관측오차와 푸리에 변환기반 재구성 과정에서 나타나는 줄무늬 모양 잡음을 효과적으로 제거하기 위해 웨이블렛 방법을 제안한다. 원형모양 오류를 프로젝션에서 제거하기 위해 해당 잡음이 각도방향으로 강한 상관관계를 가지고 있음을 이용하여, 평균화된 정보에서 해당 잡음의 강도를 추정하고 이를 웨이블렛 축소법을 통해 제거하는 방법을 제안한다. 또한, 전반적인 잡음 제거와 영상재구성을 위해 웨이블렛-배규렛 분해법을 제안한다. 제안된 방법은 기존의 푸리에 변환을 기반으로 하는 방법에 비해 원형모양 오류와 영상재구성에 있어서 우수한 영상을 제공함을 시뮬레이션을 통해 확인하였다.

  • PDF