• 제목/요약/키워드: x-ray analysis

Search Result 4,827, Processing Time 0.035 seconds

Clay Minerals and Their Distribution in the Soft Ground Deposited along the Coastline (한국 해안에 퇴적된 연약지반의 점토광물의 종류와 분포)

  • 김상규;임희대;문성권
    • Geotechnical Engineering
    • /
    • v.14 no.6
    • /
    • pp.73-80
    • /
    • 1998
  • In order to identify clay minerals in the soft ground, which has been deposited along the coastline of the Korean peninsula, 14 samples have been taken at different locations and then X-ray diffraction analysis is carried out for them. It is known from the analysis that the various kinds of clay minerals mixed with different portions exist in the soft ground, but halloysite is not traced in any samples. It is featured regionally that kaolinite and illite are found in the western coast and the southern coast. Montmorillonites exists only in the western coast. This feature of regional occurrences can be explained with the help of geology of the region. Activities determined from physical properties of the soils do not coincide with those of clay minerals identified from X-ray diffraction analysis.

  • PDF

The Comparative analysis of X-ray film on Lumbar Scoliosis and HNP by Barge Method (Barge 방식에 의한 요추부 척추측만증과 추간판 탈출증의 X-ray 비교분석)

  • Kim, Gyu-Sub
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.1
    • /
    • pp.53-61
    • /
    • 2011
  • Objective: The purpose of this study is to evaluate the disc block subluxation for lumbar scoliosis and herniation of nucleus pulpous (HNP). Methods: We used AP & Lateral view X-ray for patients. And we measured of disc wedge angle, vertebral body rotation to evaluate the typical and atypical disc block subluxation. Results: On the analysis of the lateral view X-ray, 4th lumbar intervertebral disc angle (I.V.D angle) showed $4^{\circ}$, $5^{\circ}$, $3^{\circ}$, $0^{\circ}$ in the cases. On the 4th lumbar analysis of the AP view X-ray, lumbar scoliosis showed right disc wedge angle was $11^{\circ}$ (case 1), $17^{\circ}$ (case 2) and left vertebral body rotation was 13mm, 6mm. Lumbar HNP showed left disc wedge angle was $5^{\circ}$ (case 3), $4^{\circ}$ (case 4) and left vertebral body rotation was 2mm, 4mm. Conclusions: Disc block subluxation has been in lumbar scoliosis, but not been in lumbar HNP.

  • PDF

Synthesis, Structures and Properties of Two Metal-organic Frameworks Derived from 3-Nitro-1,2-benzenedicarboxylic Acid

  • Xu, Wen-Jia;Zhang, Ling-Yu;Tang, Jin-Niu;Wang, Dai-Yin;Pan, Gang-Hong;Feng, Yu
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2375-2380
    • /
    • 2013
  • Two metal-organic frameworks based on the connectivity co-effect between rigid benzenedicarboxylic acid and bridging ligand have been synthesized $[Zn_2(3-NO_2-bdc)_2(4,4'-bpy)_2H_2O]_n$ (1), $[Co(3-NO_2-bdc)(4,4'-bpy)H_2O]_n$ (2) (where $3-NO_2-bdcH_2$ = 3-nitro-1,2-benzenedicarboxylic acid, 4,4'-bpy = 4,4'-bipyridine). The two novel complexes were characterized by IR spectrum, elemental analysis, fluorescent properties, thermogravimetric analysis, single-crystal X-ray diffraction and powder X-ray diffraction (PXRD). X-ray structure analysis reveals that 1 and 2 are two-dimensional (2D) network structures. Complex 1 and complex 2 belong to triclinic crystal with P-1 space group. The luminescence measurements reveal that two complexes exhibit good fluorescent emissions in the solid state at room temperature. Also, thermal decomposition process and powder X-ray diffraction of complexes were investigated.

Fabrication of X-ray monocapillary optics for soft X-ray fluorescence analysis (경 X선 형광분석을 위한 모세관 광학소자 제작)

  • Cho, Hyung-Wook;Park, Byung-Hoon;Kim, Yong-Min;Choi, Chul-Hee;Choi, Seong-Hee;Kim, Ki-Hong;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.409-413
    • /
    • 2011
  • An X-ray tube used an X-ray fluorescence analysis system has a low X-ray photon intensity which results in reducing measurement accuracy and increasing exposure time. These shortages can be overcame by using a monocapillary optics. A monocapillary optics was optimally designed for focusing the characteristic X-ray of tungsten (8.4 keV). The monocapillary optics can achieve a gain of 10 at the least. The monocapillary optics was fabricated by using puller and pyrex glass, raw material. In fabrication, a weigh of 45g and a temperature of $650^{\circ}$ was loaded. The total fabrication time was 460 minutes. The fabricated capillary had 87 mm in length and maximum diameter of 300 ${\mu}m$ and minimum diameter of 192 ${\mu}m$. When the fabricated monocapillary optics is applied to an X-ray fluorescence analysis system, the detection accuracy for soft elements, for example sulfur (S), will be improved.

Analysis on the Fatigue Fracture Surface of Gas Piping Material using the X-Ray Fractography (X-선 프랙토그라피에 의한 가스배관재의 피로파면해석)

  • Lim, Man-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2002
  • This study verified the relationship between fracture mechanics parameters(${\Delta}K,\;K_{max}$) and X-ray parameters ($(\sigma}_r,;B$) for G365 steel at elevated temperature up to $300{\circ}C$. The fatigue crack propagation test were carried out and X-ray diffraction technique according to crack length direction was applied to fatigue fractured surface. The residual stress on the fracture surface was found to increase in low ${\Delta}K$ region, reach to a maximum value at a certain value of $K_{max}$ or ${\Delta}K$ and then decrease. Residual stress was independent on stress ratio by arrangement of ${\Delta}K$ and half value breadth was independent by the arrangement of $K_{max}$. The equation of ${\sigma}_r-{\Delta}K$ was established by the experimental data. Therefore, fracture mechanics parameters could be estimated by the measurement of X-ray parameters.

Analysis of Continuum X-ray Specturum and Determination of Electron Temperature from Iodine Photodissociation Laser produced plasma (집속된 광분해 옥소레이저에 의한 플라즈마로부터 방출되는 연속 X-선 스펙트럼 분석과 전자온도 결정)

  • 김동환;김남성;이상수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1988.06a
    • /
    • pp.135-144
    • /
    • 1988
  • 1-GW Iodine photodissociation Laser (λ=1.315${\mu}{\textrm}{m}$)is focused to generate the continuum x-ray radiation at titanium(z=22)target. A piced of aluminum(360 )-mylar(8${\mu}{\textrm}{m}$) film is used to isolate the soft X-ray radiation emitted. Convex-xurved mica crystal spectrometer is used to obtain the soft x-ray spectra from the laser titanium target plasma and the slope of continum X-ray spectra are found to show two different different electron effective temperaturres, 0.11keV and 7.1KeV. We compare the two temperature result with the foil absorption method.

  • PDF

The Study on the Quantitative Analysis of Accident Fracture Surface by X-ray Diffraction (X-ray 회절에 의한 사고파면의 정량적 해석에 관한 연구)

  • Choi, Seong-Dae;Kweon, Hyun-Kyu;Cheong, Seon-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.4
    • /
    • pp.117-123
    • /
    • 2002
  • X-ray diffraction observation of fracture surfaces yields useful information to analyze the causes of failure accidents of engineering structures. This experimental technique, named X-ray fractography, has been developed especially in metal and mechanical engineering fields. The distributions of the residual stress and the half value breadth of diffraction profiles beneath the fatigue fracture surface were measured with SNCM 439, HT100 and Ti-6Al-4V alloy. The size of the maximum plastic zone was successfully determined on the basis of the measured distributions. This size was correlated to maximum stress intensity factor. The distributions of the half value breadth of diffraction profiles on the fatigue fracture surfaces were measured with SNCM 439. HT100. The equations of x-ray parameter distribution were possible to estimated fracture parameters of fatigue fracture surfaces.

Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique (X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF

Application of X-ray Absorption Spectroscopy (XAS) in the Field of Stabilization of As and Heavy Metal Contaminated Soil (비소 및 중금속 오염토양 안정화 분야에서의 X선 흡수분광법(XAS) 활용)

  • Lim, Jung Eun;Moon, Deok Hyun;Kim, Kwon-Rae;Ok, Yong Sik
    • Journal of Applied Biological Chemistry
    • /
    • v.58 no.1
    • /
    • pp.65-74
    • /
    • 2015
  • X-ray absorption fine structure (XAFS) analysis using X-ray absorption spectroscopy is being applied as a state-of-the-art method in a wide range of disciplines. This review article summarizes the overall procedure of XAFS analysis from the preparation of soil samples to the analysis of data in X-ray absorption near edge structure (XANES) region and extended Xray absorption fine structure (EXAFS) region. The previous studies on application of XANES and EXAFS techniques in environmental soil science field are discussed and classified them according to metal(loid)s (As, Cd, Cu, Ni, Pb, and Zn). A significant number of previous studies of XAFS application in the environmental soil science field have focused on the identification of Pb chemical species in soil. Moreover, XANES and EXAFS techniques have been widely used to investigate the contamination source via identification of metal species. Similarly, these techniques were applied to identify the mechanisms of metal stabilization in soil after application of various amendments, phytoremediation, etc.

Evaluation of Thermal Degradation of 2.25Cr-1Mo Steel Using Ultrasonic Nonlinear Effect and X-ray Diffraction Method (초음파 비선형 음향 효과 및 X-선 회절법을 이용한 2.25Cr-1Mo 강의 열화 손상 평가)

  • Kim, Duk-Hee;Park, Un-Su;Park, Ik-Keun;Byeon, Jai-Won;Kwun, Sook-In
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.71-79
    • /
    • 2002
  • It was attempted to evaluate the degree of degradation of thermally aged 2.25-1Mo steek by ultrasonic monlinear parameter(UNP) measurement and X-ray diffraction analysis of extracted carbide. Artificial aging was performed to simulate the microstructural degradation in 2.25Cr-1Mo steel arising from long time exposure at $540{\circ}C$. Microstructural analysis (number of carbides per unit area) and measurements of mechanical properties(Vickers hardness, DBTT) and degradation evaluation parameters(UNP and intensity ration of X-ray diffraction peak of electrolytically extracted carbide) were performed. Both of UNP and intensity ratio of X-ray diffraction peak for M6C carbide to that of M23C6 carbide(IR) increased abruptly in the initial 1000 hour of aging and then changed little. UNP and IR were proposed as potential parameters to evaluate the degree of aging degradation of 2.25Cr-1Mo steel.