• Title/Summary/Keyword: wrist pulse

Search Result 65, Processing Time 0.023 seconds

Analysis of Magnetic Field Variation for Pulse Wave by Using Finite Element Method (유한 요소법을 이용한 맥진 파형의 자기장 변화 분석)

  • Park, Tae-Young;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.3
    • /
    • pp.90-96
    • /
    • 2014
  • The magnetic field variation by the permanent magnet fluctuation positioned on a "Chwan" of wrist according to the movement of radial artery was generated. The clip-type pulsimeter equipped with a Hall device sensing magnetic field pulse movement analyzed the characteristics of pulse wave as output signals. The magnetic field curve and pulse waveform simulated by the finite element method were compared and analyzed with each other. Also, the variation of magnetic field distribution one permanent magnet investigated by the fabrication of clip-type pulsimeter simulator. This result suggests that the clip-type pulsimeter can be used the reproducible and efficacious oriental diagnostic medical instrument.

Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device (영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석)

  • Kim, Dong-Young;Lee, Sang-Suk;Hyeon, Seog-San;Rhee, Jin-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.146-151
    • /
    • 2014
  • The pulse waveforms of a carotid artery in the neck and a radial artery in the hand wrist were individually measured by using clip-type pulsimeter equipped with a permanent and Hall device. The pulse transit time and the pulse wave velocity obtained through comparison of two pulse waveforms were analyzed each other. A value of the pulse wave velocity was about 8.5 m/s similar to one measured by a conservative method. This result suggests that the clip-type pulsimeter as the reproducible and reliable one oriental diagnostic medical device can be predicted to any atherosclerosis state in the cardiac circulatory system.

A monitoring apparatus for pulse shape of human heartbeats by magnetic impedance sensors (자기 임피던스 센서를 이용한 맥박 측정 장치)

  • Kim, Cheong-Worl;Gu, Bon-Ju;Kim, Jong-Seong
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • A monitoring apparatus for pulse shapes of human heartbeats has been developed using an amorphous MI(Magnetic Impedance) sensor. The pulse shapes are successfully obtained from voltage signals due to the variations of magnetic impedance in the amorphous MI sensor, which is attached to a patient's wrist. This voltage signal was fed into a signal processing module to extract the pulse shapes of heartbeats. The signal processing module, which is proposed to detect a weak variations of impedance in MI sensor under a noisy measurement environment, consists of a high frequency current source, an amplifier stage and a synchronous detection circuit. To evaluate the characteristics of a newly developed apparatus, various experiments were performed. The experimental results show that the developed apparatus could be used as a diagnosis tool for traditional Korean medicine with further systematic clinical studies.

Development of Blood Pressure Measuring System using piezoelectric and photo sensor (광센서와 압력센서를 이용한 맥박측정시스템 개발)

  • Choi, Young-Suk;Kim, Kyung-Jae;Hong, Woo-Heon;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.149-154
    • /
    • 2009
  • By increasing people's average life span, interest for health is highly growing. According to hoping to check their body condition, people have a medical checkup periodically to check their condition. But, they can prevent disease or are able to make a health care through checking people's pulse or blood pressure. In this paper, two different pulse measurement systems were developed, one system using a photosensor which is able to measure transmissivity's change through blood volume and another system using a piezo-electric sensor which can measure pulse when it measures radial artery's pressure in the wrist are realized. We compared two systems each other.

Clinical Study on the Floating and Sinking Pulse Detection with Piezoresistive Sensors and Contact Pressure Control Robot (압저항 센서와 가압조절 로봇을 이용한 부침맥 검출에 관한 임상연구)

  • Lee Si-Woo;Lee Yu-Jung;Lee Hae-Jung;Kang Hee-Jung;Kim Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1673-1675
    • /
    • 2005
  • The pulse diagnosis is an important and universal method in Oriental medicine. Nevertheless, because of characteristic that depends on subjective sense of Oriental medicine doctor (OMD), it is not recognized by objective basis. The Korean Institute of Oriental Medicine(KIOM) and Daeyo Medi. Co. Ltd. developed the 3-D Mac using arrey piezoresistive sensors and multi-axial robot. 133 healthy subjects participated in this study, 75 males and 58 females, between 20 and 70 years of age. All subjects were relaxed in a supine position on a comfortable chair for twenty minutes before the measurement was taken. The measured position is the radial artery of subject's left wrist and the position is called Chon, Kwan and Chuck in Oriental medicine. To detect floating and sinking pulse, we established coefficient of floating and sinking(CFS). CFS means relative position of maximum pulse pressure in PH curve. The lower CFS value means that the pulse has floating tendency. There was significant diffence between CFS and diagnosis of floating-sinking pulse by OMD(p=0.020). CFS value of over 40's group was significantly larger than those of 20's and 30's(p=0.000). There was no significant difference between male and female(p=0.061).

Development of Wrist Type Ubiquitous Optical Sensor (손목형 유비쿼터스 광센서의 개발)

  • Hwang, Dae-Seok;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.129-132
    • /
    • 2008
  • 손목에 착용하여 맥파와 산소포화도 등의 정보를 측정할 수 있는 유비쿼터스 광센서를 개발하였다. 유비쿼터스 광센서의 SNR의 향상을 위해 660nm의 LD와 904nm의 LD를 사용하였으며, 2종류의 LD는 각각 PD를 중심으로 $120^{\circ}$로 배치하였다. 또한 정확한 신호의 측정 및 분석을 위해 LabVIEW를 사용하였다. 제작된 광센서는 정확한 맥박 및 산소포화도의 측정이 가능하였으며 Beer-Lambert 곡선과 부합하여, 구성 및 설계가 정확함을 알 수 있다.

  • PDF

A Study of Pulse Diagnosis in "Onbyeongjobyeon(溫病條辨)" ("온병조변(溫病條辨)"에 나타난 맥진(脈診) 연구(硏究))

  • Kwon, Jung-Hyun;Baik, You-Sang
    • Journal of Korean Medical classics
    • /
    • v.23 no.3
    • /
    • pp.23-48
    • /
    • 2010
  • Onbyeong(溫病) is called an acute epidemic febrile disease caused by warm pathogen, a major symptom of Onbyeong is high fever. Doctrine of Onbyeong is a study of an occurrence, progress and treatments of an acute epidemic febrile disease. Doctrine of Onbyeong is valid in the Cheong Dynasty at China. Now, a theory of doctrine of Onbyeong at China and Korea is being applied in not only an acute febrile disease but also many other lifestyle diseases. Onbyeongjobyeon is a book written by Oguktong(吳鞠通). Oguktong was influenced by Jangjung-gyeong(張仲景) "Sanghanron(傷寒論)". Oguktong had organized Seopcheonsa(葉天士)'s medical thoughts and Oguktong's medical experiences. A Samcho(三焦) deteriorated case is divided into three groups - Upper, Middle and Lower-energizer - that is discussed of a vertical progress of Onbyeong. And a Wigiyeonghyeol(衛氣營血) deteriorated case is divided into four groups - Wi, Gi, Yeong and Hyeol - that is discussed of a horizontal progress of Onbyeong. In Korean medicine, there are four types of diagnosis which are watching, listening, asking and taking. Informations, got by four types diagnosis are synthesized and classified for medical treatments. A pulse diagnosis belongs to a method by taking a wrist among four diagnosis. A Korean Medicine doctor makes a conclusion of cause, region and condition of disease by taking a pulse. Because all organs in human body are connected by a meridian system. organs conditions are reflected in a meridian system. So by taking a pulse, a progress and a prognosis of disease is diagnosed In this thesis, by taking a pulse on "Onbyeongjobyeon(溫病條辨)", a location and a feature of disease's cause with weakness and strength of a vital force are examined, and a character of a pulse diagnosis of Onbyeong is examined.

Classification method of chronic gastritis by modeling of pulse signal (맥파 모델링을 통한 만성위염 분류 기법)

  • Choi, Sang-Ho;Shin, Ki-Young;Shin, Jitae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.144-151
    • /
    • 2012
  • Chronic gastritis is the disease that is occuring in one in every 10 persons in Korea. In western medicine, endoscopy is needed to diagnose chronic gastritis, but it causes patients a pain and budget of expense. According to the TEM (Traditional Eastern Medicine), on the other hand, the 'Guan' position of the right wrist is related to a stomach. Thus we can diagnosis chronic gastritis by analyzing of pulse signal. However, pulse signal diagnosis is depended on oriental doctor's knowledge and experience. In this study, a systematic approach is proposed to analyze the computerized pulse signal. The pulse signals are firstly pre-processed, Gaussian model is adopted to fit the pulse signal, and then some related parameters are extracted from the model. Consequently, disease-sensitive parameters are selected by T-test and statistical difference. Finally, the selected parameters are entered into a Fuzzy C-Means (FCM) algorithm for classification. Classification results show that healthy persons and chronic gastritis patients are 95% and 87%, respectively.

Design and embodiment of variableness band style magnetic field nerve stimulation system that apply $1^{trigger}$ $2^{mode}$ magnetic field treatment Probe for disease treatment

  • Kim, Whi-Young;Park, Sung-Joon
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.411-416
    • /
    • 2008
  • When compose magnetic field curer by belt and band style and need by magnetic field ripple last month, produce self-discipline roof. Bred in muscle disease (lumbago, backbone disease, corpulence) back. Result that study, manufactured various variableness band style - magnetic field probe firstly. Can establish self-discipline treatment pulse price by disease secondly. Could seek correct variableness band punishment, - magnetic field probe relationship implementation and property in waist, and so on, shoulder, neck, arm, leg, ankle, wrist etc. by third. Could find variableness band style energy value that need in-magnetic field Probe's treatment by fourth. This research could design pulse of self-discipline in band form and apply each according to disease.

Optimization of Crack Based Sensor Sensitivity According to Thermal Curing Conditions of PDMS (Polydimethylsiloxane) (PDMS(Polydimethylsiloxane)의 열경화조건에 따른 크랙 이용 센서 감도 최적화)

  • Injoo Hwang;Sang-seok Yun;Yong Whan Choi
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.4
    • /
    • pp.237-241
    • /
    • 2023
  • Recently, research on flexible sensors for personal health management has been gaining attention. In this study, we fabricated a crack-based flexible sensor in thin film form to measure the pulse on the wrist. We evaluated the characteristics of the sensor based on the curing conditions of the PDMS (Polydimethylsiloxane) film to optimize the sensor's gauge factor. The modulus of PDMS varies depending on the curing conditions. In this case, the modulus of PDMS has a significant influence on crack formation, leading to changes in the sensitivity of the sensor. This study examined the changes in the gauge factor associated with these variations.