• Title/Summary/Keyword: working load

Search Result 722, Processing Time 0.029 seconds

Development of a Fleet Management System for Cooperation Among Construction Equipment (건설장비 협업을 위한 플릿관리 시스템 개발)

  • Ahn, Seo-Hyun;Kim, Sung-Keun;Lee, Kwan-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.573-586
    • /
    • 2016
  • In construction jobs, a combination of various kinds of machinery is used to perform earthworks at a large-scale site. Individual equipments essentially cooperate with each other on task such as excavation, load, transfer and compaction. While other area have studied cooperation system, related study in domestic construction is in poor condition. In this study, construction equipment fleet management system is developed for solving this problem and find way to improving efficiency in earthworks site. The entire concept of the fleet management system, including its components and process, has been systematically outlined in this paper. An operational methodology has also been suggested, where a number of machines, such as the excavators, trucks and compactors, are chosen and further grouped into a cluster. A case study verify fleet management system's effectiveness on performing task package by comparing existing work method with methodology in this study. Fleet management system in this study is expected to curtail fuel consumption by the reduction of working time and moving distance. Furthermore, it can be anticipated to declining carbon emission effect.

Evaluation of Heat Exchange Efficiency and Applicability for Parallel U-type Cast-in-place Energy Pile (병렬 U형 현장타설 에너지파일의 열교환 효율 및 적용성 평가)

  • Park, Sangwoo;Kim, Byeongyeon;Sung, Chihun;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.361-375
    • /
    • 2015
  • An energy pile is one of the novel ground heat exchangers (GHEX's) that is a economical alternative to the conventional closed-loop vertical GHEX. The combined system of both a structural foundation and a GHEX contains a heat exchange pipe inside the pile foundation and allows a working fluid circulating through the pipe, inducing heat exchange with the ground formation. In this paper, a group of energy piles equipped with parallel U-type (5, 8 and 10 pairs) heat exchange pipes was constructed in a test-bed by fabricating in large-diameter cast-in-place concrete piles. In addition, a closed-loop vertical GHEX with 30m depth was constructed nearby to conduct in-situ thermal response tests (TRTs) and to compare with the thermal performance of the cast-in-place energy piles. A series of thermal performance tests was carried out with application of an artificial cooling and heating load to evaluate the heat exchange rate of energy piles. The applicability of cast-in-place energy piles was evaluated by comparing the relative heat exchange efficiency and heat exchange rate with preceding studies. Finally, it is concluded that the cast-in-place energy piles constructed in the test-bed demonstrate effective and stable thermal performance compared with the other types of GHEX.

A study on the mechanical performance of impregnated polymer foam in cargo leakage of LNG carrier (LNG운반선의 화물 누출 시 함침된 고분자 폼의 기계적 성능에 관한 연구)

  • Park, Gi-Beom;Kim, Tae-Wook;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.345-352
    • /
    • 2017
  • In this study, the effect of cryogenic liquefied natural gas leakage and loading on liquefied natural gas cargo hold is investigated to observe the performance of the polymer foam material that comprises the cryogenic insulation of the cargo hold. The primary barriers of liquefied natural gas carrier that are in contact with the liquefied natural gas will leak if damage is accumulated, owing to fluid impact loads or liquefied natural gas loading / unloading over a long period. The leakage of the cryogenic fluid affects the interior of the polymer foam, which is a porous closed cell structure, and causes a change in behavior with respect to the working load. In this study, mechanical properties of polyisocyanurate foam specimen, which is a polymer material used as insulation, are evaluated. The performance of the specimens, owing to the cold brittleness and the impregnation effects of the cryogenic fluids, are quantitatively compared and analyzed.

Performance Analysis of MBMS and Wi-Fi Priority Policy in Heterogeneous Networks having a dispersed Single-cell MBMS (분산된 단일 셀 MBMS을 지원하는 이종 네트워크 환경에서 MBMS와 와이파이 사용자 우선 정책에 대한 성능 분석)

  • Jeong, Un Ho;Lee, Jung Moon;Kim, Gi Taek;Nam, Boo Hee;Kim, Dong Hoi
    • Journal of Broadcast Engineering
    • /
    • v.18 no.2
    • /
    • pp.215-224
    • /
    • 2013
  • With the rising popularity of smart-phones, the supply of Internet protocol television is largely increased and it causes the wireless communication network load to be increased. To overcome such an overloading problem, 3GPP is now working on the standardization of MBMS since LTE Release 6 specification. MBMS has good performance in bandwidth efficiency by sharing the same bandwidth with the mulitple MBMS users having the same content. According to the proposed algorithm, in heterogeneous networks having a dispersed Single-cell MBMS where 3GPP network and Wi-Fi network are mixed, if the number of MBMS users, who are belonging to cells supporting a dispersed Single-cell MBMS, is more than a specified threshold, the MBMS priority policy is operated. Otherwise, the Wi-Fi priority policy is executed. As the simulation results show both the increase of total available bandwidth ratio and the decrease of network usage cost, it is confirmed that the proposed scheme allows the network efficiency to be maximized.

A Study on the Energy-saving Variation by the Reduction of Insulation Boundary in Mixed-use Building (주상복합건물에서 단열 경계구역 축소에 따른 에너지 절감량 변화에 관한 연구)

  • Kim, Dae-Won;Kim, Young-Il;Kim, Sung-Min;Cho, Jin-Hwan;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.152-157
    • /
    • 2012
  • Due to the global warming and energy exhaustion, energy efficiency improvement of construction is recognized the stream of times. To improve the efficiency of the building, in order to energy saving, passive elements should be applied. Then the first step be supposed that applying the new standards about the insulation boundary. The current insulation boundary standards are not reasonable as well as does not divide the purposes. As a result, energy is being wasted and many civil complaints are also occurred. To improve these problems, applying the insulation boundary need to divide the heating and non-heating and subdivide the purpose of construction. In this study, accurate real heating and air conditioning areas are presented that work on the new insulation boundary of purposes and applicable standards. This proposed, by the real heating and air conditioning areas, insulation boundary of purposes, matching the reasonable capacity and load of equipment, by working on standards by optimal maintenance can be energy saving, to present guidelines that environment improvement of actual residents as well as energy saving be expected.

A Case Study of Underwater Blasting (수중발파 사례 연구)

  • 정민수;박종호;송영석
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.57-64
    • /
    • 2004
  • There are two major types of underwater blasting at Korea, bridges and harbor construction work. Pier blasting for lay the foundation bridges construction is used dry excavation working (drilling and charging) after pump out water and then fire pump in water that is same as bench blasting. In contrast, underwater blasting for harbor construction and increase of harbor load depth is used to barge with digging equipment that is in oder to drilling on the surface and blasting work(charge, hook-up) under water. Thus, there are need to special concern such as charge method and hook-up method different from tunnel blasting work and bench blasting work. If do not use special concern breaks out dead pressure and mis fire because of there are so many difficult condition such as water pressure, obstruct field of vision. In this study underwater blasting at Busan Harbor Construction have consider with special concern that is plastic pipe charge method used to MegaMITE I and specialized buoy hook- up method make far initial system detonate on the surface used to TLD. The results is designed blast pattern charge per delay effect an inspection of verify between predict velocity and measure velocity. minimized break out mis fire consideration charge method, hook up method. According to result best underwater blasting design is 105mm drilling dia, MeGAMITE II, HiNLL Plus(non electric detonator).

The Physiological Responses and Subjective Sensation in the Subjects Wearing Dust-free Garment for Semiconductor Industrial Environments (방진복 착용에 따른 인체의 온열생리적 특성 및 주관적 감각)

  • 권오경;이창미
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.255-263
    • /
    • 1998
  • Dust-free garment prevents contamination which otherwise is caused by skin and clothes to protect from dust or dirt. Therefore, it requires high performance and should function as a working clothes. Clothes are a medium between human and thermal environmental system, and it is required to study human enviroment to ensure comfortableness of clothes and to satisfactorily go along with enviroment .This study investigates the physical and physiological features of dust-free garment used in the clean room at a semiconductor factory in oredr to scientifically clarify what the dust-free garmint is as well as to contribute to the design and development of high performance material and clothes. Three kinds of dust-free fabrics (DFG-I, DFG-II, DFG-III) which are being developed by a local company are used to manufacture dust-free garment. These dust-free garments are dressed and tested in such an enviroment as similar to semiconmemts with temperature at 23${\pm}$1$^{\circ}C$ and humidity at 50${\pm}$5%RH in order to investigate the thermo physiological and psychological features of human body. The results of this study are as follows. The results of this study are as follows. 1.The mean skin temperature was significantly different among the clothes, subjects and experimental time. Temperature tends to rise from the time of exercising load. Continuous motion coupled sealed clothes prevents heat transmittance, and temperature rises in the order of DFG-l, DFG-ll and DFG-lll as time course. 2.As for the skin temperature by local timperature is minimun on the head and torso and increares remarkably at the terminal part of human body. 3. As for the body mass loss was significantly higher in DFG-lll than DFG-l and DFG-ll. 4. Though there is no significant difference in the temperature within clothes among the kind of clothes temperature is 1$^{\circ}C$ higher in the back. Temperature within all the dust-free garments 29.7$^{\circ}C$ in the back and 31.3$^{\circ}C$ in the chest which belong to the comfort zone(31-33$^{\circ}C$). The relative humidity is 39.7%RH in the chest and 33.8%RH in the back which is slightly below the comfort zone(40-60%RH) 5. The thermal sensation belong to the comfort zone regardless of the kinds of clothes. The subjects feels a slight fatigue as times goes. As for the subjective sense of subjects the mean skin temperature as well as temperature and humidity within clothes show similar tendency. This means that they relate with each other.

  • PDF

A Study on Emotional Labor, Emotional Burnout, Turnover Intention of Dental Hygienist (치과위생사의 감정노동, 감정소진, 이직의도에 관한 연구)

  • Jeong, Kyung-Yi;Han, Ok-Sung
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.280-286
    • /
    • 2015
  • The purpose of this study was to examine dental hygienist's emotional labor, burnout and turnover intention. Data were collected from 215 dental hygienists working at hospitals and dental clinics through self-administered questionnaire, and analyzed by statistical analysis using t-test, ANOVA, Pearson's correlation coefficient and multiple regression analysis. The main findings of the study are as follows: the higher the educational level of dental hygienists, and the bigger the size of dental institutions they work, and the lower the monthly income of dental hygienists, the higher the level of emotional labor of dental hygienists. Burnout was influenced on emotional labor and turnover intention. Emotion labor and turnover intention were influenced on burnout. Tenure under 5 years, five-day workweek (non), emotional burnout were found to have significant effects on the turnover intention. Dental hygienists were doing relatively high emotional labor, and it influences his burnout experience and turnover intention. It is needed to make the workplace better environment which can secure appropriate work load and rewards, and education programs etc.

A Study on the Preventive Measures against Fall Injuries in Manufacturing Industry Focusing on the Portable Ladders (이동식 사다리를 중심으로 한 제조업에서의 추락재해 예방대책 연구)

  • Kim, Hyung-Seok;Lee, Seok-Won;Jung, Won-Jae;Ryu, Bo-Hyuk
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.136-143
    • /
    • 2009
  • The injuries as a result of fall accidents is the one of the most common kind of injuries in Korea, especially fall from height is the top most common kind for fatal injuries. Futhermore, the number of fall injuries in manufacturing industry has been steadily increasing from 2000 to 2007. In 2007 the number of fall fatal injuries increased 10.6 % in comparison with the number in 2006. These numbers are 6~17 times higher than those for foreign countries such as the U.K and the USA. So, it is needed to make a study to reduce these numbers for manufacturing industry. To get the goals, we did research as followings. First, this study analyzed statistics by industry, by fall height, by common agent and so on to gain an insight into real aspect of fall injuries. It showed that ladder is the commonly cited agent for manufacturing industry, and 3 risky activities ; the ladder work, the load/unload work, and the maintenance work. Secondly, this study made a survey of manufacturing workers for their understandings of the most 3 risky activities. It showed that 'tendency to work easily' and 'difficulty of applying measures due to inherent working conditions' are main reasons for workers not to implement the preventive measures against the fall accidents. Thirdly, this study tested the slip characteristics of ladder base and lungs. The tests were done based on ANSI standard and KS. In addition to the standard condition, this study performed slip tests in wet and sandy conditions and compared the results with the those of standard condition. It showed that friction coefficient is standard condition > wet condition > sandy condition, and the friction coefficient of ladder for sandy condition is measured to be reduced by 63.9% compared with that for standard condition. Finally, this study developed safety work models for using of portable ladders in consideration of the safety standards of foreign countries such as the U.K, the USA, and the Australia.

Relationship between Occupational Stress and Work-related Factors in Dental Hygienists (치과위생사의 직무스트레스와 직무요인의 관계)

  • Lee, So-Young;Yu, Byeng-Chul
    • Journal of dental hygiene science
    • /
    • v.11 no.6
    • /
    • pp.553-562
    • /
    • 2011
  • This study was purposed to evaluate the level of occupational stress and the work-related factors of occupational stress in dental hygienists. The study was conducted during the period from May to October 2010 with study population consisted of 316 dental hygienists. The occupational stress was estimated with questionnaire of the Korean Occupational Stress Scale(KOSS) and the work-related factors were consisted with 9 work characteristics. Data analysis was performed with t-test, ANOVA and multiple regression analysis using SPSS(win ver 18.0) program. The level of occupational stress was $52.42{\pm}4.95$ in dental hygienists. The levels of sub-scales for occupational stress were $64.56{\pm}12.17$ in interpersonal conflict, $59.85{\pm}13.59$ in physical environment, $54.60{\pm}13.51$ in organizational system, $52.37{\pm}11.47$ in job demand, $51.71{\pm}10.58$ in lack of reward, $48.14{\pm}12.97$ in insufficient job control, $46.68{\pm}9.25$ in job insecurity, $41.46{\pm}15.98$ in occupational climate, respectively. According to multiple regression analysis, physical burden and daily repetitive working hour were work-related factors of occupational stress in dental hygienists. To conclude, the occupational stress in dental hygienists was higher than mean score of reference values of occupational stress in Korean workers and methods for reducing work load and work hours considering work characteristics of dental hygienist are needed to prevent occupational stress in dental hygienists.