• 제목/요약/키워드: working gas

Search Result 704, Processing Time 0.027 seconds

A Study on the Analysis of the Resistance Characteristics and Damage Patterns of Brass Fittings Type CSST (황동이음쇠형 금속플렉시블호스(CSST)의 저항 특성 및 소손 패턴 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • This paper examined the structure, fire resistance of brass fittings type CSST employed in gas appliances and the reliability verification. Brass fittings of type CSST consisted of cladding, tubing, nut, clamp ring, socket, and ball valve. The applicable JIA standard regulates the maximum working pressure to be 4.2 kPa, which is the highest pressure of the relevant standards and the KS D 3625 stipulates the maximum pressure to be 3.24 kPa. With a normal product, the average resistance within the confidence interval was found to be $7.36m{\Omega}$. The average resistance within the confidence interval was $6.67m{\Omega}$ after the fire resistance tests. The analysis indicated that the AD was 1.584 and the standard deviation was 0.3972 with respect of a normal product. Compared to the normal product, however, the damaged product after the fire resistance test showed better features, such as an AD of 1.145 and a standard deviation of 0.2467. Moreover, the average resistance of the normal product was $7.359m{\Omega}$ and the standard deviation in histogram analysis was 0.3972. The average resistance of the damaged product after the fire resistance test in the histogram was $6.67m{\Omega}$ and the standard deviation was 0.2467.

Analysis of an internal flow with multi-perforated tube geometry in an integrated Urea-SCR muffler (다공튜브 형상변화에 따른 촉매 삽입형 Urea-SCR 머플러 내부유동 해석)

  • Moon, Namsoo;Lee, Sangkyoo;Lee, Jeekeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.500-509
    • /
    • 2013
  • This study reports a numerical analysis of the internal flow characteristics of the integrated urea-SCR muffler system with the various geometries of the multi-perforated tube which is set up between the muffler inlet and in front of SCR catalysts. The multi-perforated tube is generally used to disperse uniformly the urea-water solution spray and to make better use of the SCR catalyst, resulting in the increased $NO_x$ reduction and decreased ammonia slip. The effects of the multi-perforated tube orifice area ratios on the velocity distributions in front of the SCR catalyst, which is ultimately quantified as the uniformity index, were investigated for the optimal muffler system design. The steady flow model was applied by using a general-purpose commercial software package. The air at the room temperature was used as a working fluid, instead of the exhaust gas and urea-water solution spray mixture. From the analysis results, it was clarified that the multi-perforated tube geometry sensitively affected to the formation of the bulk swirling motion inside the plenum chamber set in front of the SCR catalyst and to the uniformity index of the velocity distribution produced at the inlet of the catalyst.

Investigation of the Guidance Levels for Protecting Populations from Chemical Exposure and the Estimation of the Level of Concern Using Acute Toxicity Data (화학사고 시 수용체 보호를 위한 독성끝점 농도와 급성독성 자료를 활용한 우려농도 예측값 조사)

  • Lee, Jiyun;Kim, Sunshin;Yang, Wonho;Yoon, Junheon;Ryu, Jisung;Kim, Jungkon;Ji, Kyunghee
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.1
    • /
    • pp.44-54
    • /
    • 2018
  • Objectives: To protect individuals working at the site as well as the surrounding general population from a chemical accident, several emergency exposure guidance levels have been used to set a level of concern for certain chemicals. However, a level of concern has not been established for many substances that are frequently used or produced in large quantities in Korean workplaces. In the present study, we investigated the guidance levels for protecting populations from chemical exposure and the estimation of level of concern using acute inhalation and oral toxicity data. Methods: The number of chemicals to which emergency exposure guidance levels (e.g., ERPG-2, AEGL-2, PAC-2, and IDLH) can be applied were determined among 822 hazardous chemicals according to the 'Technical Guidelines for the Selection of Accident Scenarios (revised December 2016)'. The ERPG and AEGL values were compared across all three tiers for the 31 substances that appeared on both lists. We examined the degree of difference between the emergency exposure guidance levels and the estimates of level of concern calculated from acute inhalation or acute oral toxicity data. Results: Among the 822 hazardous chemicals, emergency exposure guidance levels can be applied to 359 substances, suggesting that the estimates of level of concern should be calculated using acute toxicity data for 56.3% of the hazardous chemicals. When comparing the concordance rates of ERPG and AEGL for 31 substances, the difference between the two criteria was generally small. However, about 40% of the substances have values diverging by more than three-fold in at least one tier. Such discrepancies may cause interpretation and communication problems in risk management. The emergency exposure guidance levels were similar to the estimates of level of concern calculated using acute inhalation toxicity data, but the differences were significant when using acute oral toxicity data. These results indicate that the level of concern derived from acute oral toxicity data may be insufficient to protect the population in some cases. Conclusion: Our study suggests that the development of standardized guidance values for emergency chemical exposure in the Korean population should be encouraged. It is also necessary to analyze acute toxicity data and fill the information gaps for substances that are important in Korean workplace situations.

Experimental Investigation on the Droplet Entrainment in the Air-Water Horizontal Stratified Flow (물-공기 수평 성층류 유동조건에서 액적이탈 현상에 대한 실험연구)

  • Bae, Byeong Geon;Yun, Byong Jo;Kim, Kyoung Doo;Bae, Byoung Uhn
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.114-122
    • /
    • 2015
  • In the high convective gas flow condition, irregular shaped water waves from which droplet entrainment occurs are generated under horizontally stratified two-phase flow condition. KAERI proposed a new mechanistic droplet entrainment model based on the momentum balance equation consisting of the shear stress, surface tension, and gravity forces. However, this model requires correlation or experimental data of several physical parameters related to the wave characteristics. In the present study, we tried to measure the physical parameters such as wave slope, wave hypotenuse length, wave velocity, wave frequency, and wavelength experimentally. For this, an experiment was conducted in the horizontal rectangular channel of which width, height, and length are, respectively, 40 mm, 50 mm, and 4.2 m. In the present test, the working fluids are chosen as air and water. The PIV technique was applied not only to obtain images for phase interface waves but also to measure the velocity field of the water flow. Additionally, we developed the parallel wire conductance probe for the confirmation of wave height from PIV image. Finally, we measured the physical parameters to be used in the validation of new droplet entrainment model.

Development of Work Breakdown Structure and Analysis of Precedence Relations by Activity in School Facilities Construction Work (학교시설 건설공사의 작업분류체계 구축 및 단위작업별 선후행 관계 분석)

  • Bang, Jong-Dae;Sohn, Jeong-Rak
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.189-200
    • /
    • 2017
  • The work breakdown structure and the precedence relations by work activity are very important because they are the basic data for estimating the construction duration in the construction work. However, there is no standard to accurately estimate the construction duration since the size of the school facilities construction is smaller than the general construction work. Therefore, some schools are unable to open in March or September and the delay of the construction duration can cause damage to the students. To solve this problem, this study developed a work breakdown structure of school facilities construction work and analyzed the precedence relations by work activities. The work breakdown structure of the school facilities construction is composed of three steps. The operations corresponding to level 1 and level 2 are as follows. (1) 2 preparatory work categories; preparation period and temporary construction. (2) 17 architectural work categories; temporary construction, foundation & pile work, reinforced concrete work, steel roof work, brick work, plaster work, tile work, stone work, waterproof construction, wood work, interior construction, floor work, metal work, roof work, windows construction, glazing work and paint construction. (3) 7 mechanic and fire work categories; outside trunk line work, plumbing work, air-conditioning equipment work, machine room work, city gas plumbing work, sanitation facilities and inspection & test working. (4) 4 civil work categories; wastewater work, drainage work, pavement work and other work. (5) 1 landscaping work categories; planting work. The work breakdown structure was derived from interviews with experts based on the milestones and detailed statements of existing school facilities. The analysis of precedence relations by school facilities work activity utilized PDM(Precedence Diagramming Method)which does not need a dummy and the relations were applied using FS(Finish to Start), FF(Finish to Finish), SS(Start to Start), SF(Start to Finish). The analysis of this study shows that if one work activity is delayed, the entire construction duration may be delayed because the majority of the works are FS relations. Therefore, it is necessary to use the Lag at the appropriate time to estimate the standard construction duration of the school facility construction. Lag is a term used only in the PDM method and it is used to define the relationship between the predecessor and the successor in creating the network milestone. And it means the delay time applied to the two work activities. The results of this study can reasonably estimate the standard construction duration of school facilities and it will contribute to the quality of the school facilities construction.

Evaluation of Effective Dose and Exposure Level of Radon in Process Handling NORM (인산석고 취급공정에서의 라돈농도 및 유효선량 수준 평가)

  • Chung, Eun Kyo;Jang, Jae Kil;Kim, Jong Kyu;Kim, Joon Beom;Kwon, Jiwoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.3
    • /
    • pp.283-291
    • /
    • 2018
  • Objectives: To monitor the radon concentration level in plants that handle phosphorus rock and produce gypsum board and cement, and evaluate the effective dose considering the effect of radon exposure on the human body. Methods: Airborne radon concentrations were measured using alpha-track radon detectors (${\alpha}$-track, Rn-tech Co., Korea) and continuous monitors (Radon Sentinel 1030, Sun Nuclear Co., USA). Radon concentrations in the air were converted to radon doses using the following equation to evaluate the human effects due to radon. H (mSv/yr) = Radon gas concentration x Equilibrium factor x Occupancy factor x Dose conversion factor. The International Commission on Radiological Protection (ICRP) used $8nSv/(Bq{\cdot}hr/m^3)$ as the dose conversion factor in 2010, but raised it by a factor of four to $33nSv/(Bq{\cdot}hr/m^3)$ in 2017. Results: Radon concentrations and effective doses in fertilizer manufacturing process averaged $14.3(2.7)Bq/m^3$ ($2.0-551.3Bq/m^3$), 0.11-0.54 m㏜/yr depending on the advisory authority and recommendation year, respectively. Radon concentrations in the gypsum-board manufacturing process averaged $14.9Bq/m^3$ at material storage, $11.4Bq/m^3$ at burnability, $8.1Bq/m^3$ at mixing, $10.0Bq/m^3$ at forming, $8.9Bq/m^3$ at drying, $14.7Bq/m^3$ at cutting, and $10.5Bq/m^3$ at shipment. It was low because it did not use phosphate gypsum. Radon concentrations and effective doses in the cement manufacturing process were $23.2Bq/m^3$ in the stowage area, $20.2Bq/m^3$ in the hopper, $16.8Bq/m^3$ in the feeder and $11.9Bq/m^3$ in the cement mill, marking 0.12-0.63 m㏜/yr, respectively. Conclusions: Workers handling phosphorous gypsum directly or indirectly can be assessed as exposed to an annual average radon dose of 0.16 to 2.04 mSv or 0.010 to 0.102 WLM (Working Level Month).

A Study on the Effect Analysis and Improvement of Cardiopulmonary Resuscitation on Life-rafts (구명뗏목에서의 비상대응 심폐소생술의 효과 분석 및 개선에 관한 연구)

  • Lee, Chang-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.433-440
    • /
    • 2019
  • Offshore working environments such as ships, offshore oil and gas plants, and offshore wind turbines are isolated and directly exposed to rough seas, which pose high risks of safety accidents. Therefore, all workers in offshore plants should be able to cope with emergency situations and must be qualified according to relevant laws and regulations such as the International Convention on Standards of Training, Certification and Watchkeeping for Seafarers (STCW Convention) and Offshore Petroleum Industry Training Organization (OPITO) standards. In particular, marine workers should be able to perform cardiopulmonary resuscitation (CPR) in isolated locations or enclosed and confined spaces such as those in life-boats, life-rafts, rescue-boats, etc. Because the floor material is made of rubber, it may be difficult to perform chest compressions in life-rafts used to escape from emergency situations in ships or offshore plants. Chest compressions performed on life-rafts may reduce the accuracy of CPR and increase fatigue for those providing aid. To measure the accuracy and fatigue of those performing CPR in life-rafts, 15 experimenters with more than five years of experience as first aid instructors were exposed to different CPR environments in a marine safety training center equipped with an artificial wave generator. The results showed that the accuracy of CPR in the classroom was 99.6 %, but that in various life-raft environments was only 84 %. T-verification of the two sites confirmed the reduced accuracy of CPR performed on life-rafts. CPR on life-rafts should be performed in groups of two and with the use of automated chest compression devices.

A Study on the Element Technologies in Flame Arrester of End Line (선박의 엔드라인 폭연방지기의 요소기술에 관한 연구)

  • Pham, Minh-Ngoc;Choi, Min-Seon;Kim, Bu-Gi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.468-475
    • /
    • 2019
  • An end-line flame arrester allows free venting in combination with flame protection for vertical vent applications. End-line flame arresters are employed in various fields, especially in shipping. In flame arresters, springs are essential parts because the spring load and the spring's elasticity determine the hood opening moment. In addition, the spring has to work under a high-temperature condition because of the burning gas flame. Therefore, it is necessary to analyze the mechanical load and elasticity of the spring when the flame starts to appear. Based on simulations of the working process of a specific end-line flame arrester, a thermal and structural analysis of the spring is performed. A three-dimensional model of a burned spring is built using computational fluid dynamics (CFD) simulation. Results of the CFD analysis are input into a finite element method simulation to analyze the spring structure. The research team focused on three cases of spring loads: 43, 93, and 56 kg, correspondingly, at 150 mm of spring deflection. Consequently, the spring load was reduced by 10 kg after 5 min under a $1,000^{\circ}C$ heat condition. The simulation results can be used to predict and estimate the spring's load and elasticity at the burning time variation. Moreover, the obtained outcome can provide the industry with references to optimize the design of the spring as well as that of the flame arrester.

Explosion Likelihood Investigation of Facility Using CVD Equipment Using SEMI S6 (SEMI S6를 적용한 CVD 설비의 폭발분위기 조성 가능성 분석)

  • Mi Jeong Lee;Dae Won Seo;Seong Hee Lee;Dong Geon Lee;Se Jong Bae;Jong-Bae Baek
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.62-67
    • /
    • 2023
  • Due to the prolonged impact of COVID-19, the demand for Information Technology (IT) products is increasing, and their production facilities are expanded. Consequently, the use of harmful and dangerous chemicals are increased, the risk of fire(s) and explosion(s) is also elevated. In order to mitigate these risks, the government sets standards, such as KS C IEC 60079-10-1, and manages explosion-prone hazardous facilities where flammable substances are manufactured, used, and handled. However, using the standards of KS, it is difficult to predict the actual possibility of an explosion in a facility, because ventilation (an important factor) is not considered when setting up a hazardous work environment. In this study, the SEMI S6, Tracer Gas Test was applied to the chemical vapor deposition (CVD) facility, a major part of the display industry, to evaluate ventilation performance and to confirm the possibility of creating a less explosive environment. Based on the results, it was confirmed that the ventilation performance in the assumed scenarios met the standards stipulated in SEMI S6, along with supporting the possibility of creating a less explosive working condition. Therefore, it is recommended to use the prediction tool using engineering techniques, as well as KS standards, in such hazardous environments to prevent accidents and/or reduce economic burden following accidents.

A study on environmental status, FIM and Illness intrusiveness of home stayed stroke patients (재가 노졸중 환자의 환경상태, 기능적 독립, 질병으로 인한 장애영향에 관한 연구)

  • Kim, Keum Soon;Roh, Kook Hee
    • 한국노년학
    • /
    • v.25 no.2
    • /
    • pp.143-154
    • /
    • 2005
  • This study was conducted to examine the environmental status, FIM(Function Independence Measure), Illness intrusiveness of home stayed stroke patients. Data were collected on 145 patients living in K city and the neighborhood located in southern part of Korea. The data were analyzed by means of SPSS program. Results : In assessment of environmental safety, 46.2%(67) felt unsafe around their residential area. The most dangerous facilities in their residence was stairs(58.2%), gas/electric facilities(14.9%). For sanitary problems, 28.2%(41) felt they have problems at their home. The most important problems were outdoor polluted toilet(22.0%) and scattered and dirty residential circumstances(22.0%). The average FIM score was 74.52(4.14) of total score 126(7). In motor area FIM was lowest at stair walking(3.01) and bathing(3.16). In cognitive area FIM was lowest at social activities(3.36). The mean score of Illness intrusiveness was 58.86(4.52) of total score 91(7). The major area largely impacted by stroke were health(5.61), working(5.68), active leisure activities(5.56). There was significant reverse correlation between FIM and illness intrusiveness(r=-0.66, p=0.00). Conclusion : It was needed environmental improvement and rehabilitation program for stroke patients, and repeated follow up study.