• 제목/요약/키워드: work counter

검색결과 206건 처리시간 0.027초

A STUDY ON THE SAFETY INFORMATION SYSTEM TO PREVENT HAZARD OF BUILDING CONSTRUCTION

  • Han-Min Lee;Seong-Seok Go;Hyuk Song;Hyun-Chul Lee
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.1048-1052
    • /
    • 2005
  • In Korean cases, the occupation of building construction is below 10% of the total industry workers but from a accident rate point of view, it is a risk serious industry and it's hazard is very considerable which accident rate is up to 30% of the total industry workers. The reason of high accident rate of the building construction is its own characteristic, hazard of the work in which is implicated and the shortage of safety counter plan and information, so it is most required to the building construction that educating, training, short and long period approaching to prevent the hazard. The safety information of building construction which is related to safety accident is divided into human and material such as hazard, work situation, cause and counter plan. The existing hazard cases imply all of the information about the work type and work progress of the building construction, so if the research of the every fact is well accomplished, we can obtain the useful information and prevent the hazard of building construction. From this point of view, the emphasis of this study is based on analyzing the cause of hazard first, suggesting the safety information each part of work type and work progress second, and finally making the all existing hazard cases to the Data Base and developing the safety information system.

  • PDF

부품 및 벤치 실험을 통한 폴리우레탄 유압 왕복 실의 가속 실험 (Component and Bench Tests of Polyurethane Hydraulic Reciprocating Seal for Accelerated Life Testing)

  • 제영완;김한솔;김류운;정구현;안중혁;전홍규
    • Tribology and Lubricants
    • /
    • 제30권5호
    • /
    • pp.271-277
    • /
    • 2014
  • Hydraulic reciprocating seals have been widely used to prevent fluid leakage and to provide lubricant film on counter surface in various hydraulic system. The degradation of the seal may cause the catastrophic failure of the hydraulic system. To assess the durability of the seals and the compatibility with counter surface, accelerated life testing (ALT) has been typically employed from industry. However, ALT often takes up to a few months to cause a failure of the seals, and therefore, there is a need to develop more efficient ALT methods. In this work, the degradation characteristics of polyurethane (PU) seals from field test are investigated and they are compared to those from the component and bench tests, with an aim to contribute to the development of ALT method. From the comparison of the cross-sectional profiles of the sealing surface of the PU specimens before and after the tests, both wear and compression set are found to be responsible for degradation of the PU seals. It is also shown that the major wear mechanisms of the PU seals from the field is abrasive wear and formation of pits. The component and bench tests performed in this work are shown to reproduce such wear mechanisms, and therefore, those test methods can be used as an ALT method for PU seals. In particular, the bench test proposed in this work may be effectively utilized to assess the durability and the compatibility of the seals with the counter surface. The results of this work are expected to aid in the design of ALT for PU seal.

철탑접지저항 측정에 관한 연구 (A Study on Measurement for Earth Resistance of Steel Structure)

  • 박석탁;김시영
    • 전기의세계
    • /
    • 제22권6호
    • /
    • pp.33-51
    • /
    • 1973
  • To lower the earth resistance shall be one of the most effective method for the prevention of lightening damage on power transmission line. In this report, in order to investigate various characteristic necessary to lowering the earth resistance, the following experiments have been made at 154KV U1San-PoHang T/L, 154KV YoSu-SoonChun T/L and so on. 1. Measurement of Earth specific resistance, 2. Efficiency of Earthing of concrete foundation for steel structure., 3. Efficiency of Earthing with counter poise., 4. Compound impulse test with foundation of steel structure and counter poise. With the above investigate a guidance have been prepared for the effective work-performance of steel structure.

  • PDF

박판 평 블록 구조의 용접변형 제어법 개발(I) (Development of Welding Distortion Control Method for Thin Panel Block Structure(I))

  • 허주호;김상일
    • Journal of Welding and Joining
    • /
    • 제21권4호
    • /
    • pp.75-79
    • /
    • 2003
  • The welding distortion of a hull structure in the shipbuilding industry is inevitable at each assembly stage. This geometric inaccuracy caused by the welding distortion tends to preclude the introduction of automation and mechanization and needs the additional man-hours for the adjusting work at the following assembly stage. To overcome this problem, a distortion control method should be applied. For this purpose, it is necessary to develop an accurate prediction method which can explicitly account for the influence of various factors on the welding distortion. The validity of the prediction method must be also clarified through experiments. For the purpose of reducing the weld-induced bending deflection, this paper proposes the plastic counter-deforming method (PCDM) using the line heating as the optimum distortion control method. The validity of this method has been substantiated by a number of numerical simulations and actual measurements.

Effect of Axial Spacing between the Components on the Performance of a Counter Rotating Turbine

  • Subbarao, Rayapati;Govardhan, Mukka
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권4호
    • /
    • pp.170-176
    • /
    • 2013
  • Counter Rotating Turbine (CRT) is an axial turbine with a nozzle followed by a rotor and another rotor that rotates in the opposite direction of the first one. Axial spacing between blade rows plays major role in its performance. Present work involves computationally studying the performance and flow field of CRT with axial spacing of 10, 30 and 70% for different mass flow rates. The turbine components are modeled for all the three spacing. Velocity, pressure, entropy and Mach number distributions across turbine stage are analyzed. Effect of spacing on losses and performance in case of stage, Rotor1 and Rotor2 are elaborated. Results confirm that an optimum axial spacing between turbine components can be obtained for the improved performance of CRT.

사고사례에 기초한 보일러 사고의 원인분석 및 대책 (Cause Analyses of Boiler Accident and Their Counter-plans Based on Accident Cases)

  • 윤상권;장통일;임현교
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.131-140
    • /
    • 2003
  • An accident involving a boiler can result in a disaster since it handles high-pressurized steam so that it may cause an explosion. Therefore, the boiler is very susceptible to industrial accidents. This thesis aimed to develop counter-plans to prevent industrial accidents involved the boiler. At first after collecting accident cases involving boilers, a survey on the trait of them was carried out. Ant on the other hand a qualitative analysis was conducted to draw out hazardous components in the boiler itself and their inherent relative importance was assessed. Through this procedure, 'negligence of unsafe condition' was noted as the major cause for unsafe acts whereas 'fault in work procedure' for unsafe condition. In the meanwhile, results of a hazard analysis using FMEA technique ranked gas safety devices, a switch preventing gas from under-pressurization, protect relays high. In particular, it was pointed out that the water feeding and steam subsystem has more components in hazard than other subsystems. Considering these analyses results, counter-plans to improve safety management was suggested also.

성능계수 향상을 위한 10 kW급 상반전 조류터빈의 설계 (A Design of 10 kW Class Counter-Rotating Tidal Turbine Focusing on the Improvement of Operating Performance)

  • 황안둥;김부기;김준호;양창조
    • 한국유체기계학회 논문집
    • /
    • 제18권3호
    • /
    • pp.53-59
    • /
    • 2015
  • Tidal turbine, which is relatively similar to wind turbine in term of operational principle, has become a potential solution for the sustainable development of global energy. This paper introduces author's work on tidal turbine which aims to improve the power efficiency by the adaption of counter-rotating concept. The turbine system is modelled and analyzed using computational simulation commercial code. Compared with other works, the counter-rotating tidal turbine presented here is expected to operate stably with high performance throughout a wide range of tip-speed-ratio. Moreover, the equability of individual performance of each rotor is an advantage.

A Study on the Method of Nonlinearity Correction in a GM Counter

  • Ha, Chung-Woo;Yook, Chong-Chul;Philip S. Moon
    • Nuclear Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.137-144
    • /
    • 1978
  • 계측장치에서 관측한 계수율에 대한 비직선성 교정을 결정하는 한 방법을 제시하였다. 불감시간은 계수율이 의존성을 가지고 있다는 가정하에서 발전시킨 한 표현식은 실험결과와 잘 일치하였다. 계측장치의 펄스전압의 계수율에 따른 ,변화량을 파고분석장치를 이용하여 측정 하였다. 이 방법은 광범한 계수율 범위에 걸치어 불감시간에 대한 정착찬 값을 주었다. 개요한 이 측정기술로 불감손실로 인한 비직선성의 정확한 교정할 수 있었다. 불감시간은 계수율이 증가함에 따라 감소하는 것이 관측되었다.

  • PDF

The Effect of Gap Size on Counter Current Flow Limitation Phenomena in Narrow Annular Gaps with Large Diameter

  • Jeong, Ji-Hwan;Lee, Seung-Jin;Park, Rae-Joon;Kim, Sang-Baek
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.396-405
    • /
    • 2002
  • An experimental study on counter-current flow limitation phenomena in narrow annular passages was carried out The gap sizes tested were 1, 2 and 3 mm. This is very small compared with the outer diameter of the annular passage, 500 mm. It was visually observed that a CCFL might occur in some part of the periphery while the other part is remained in a counter current flow pattern. That is, non-uniform behaviour of fluids due 4o a 2-dimensional effect appear in a large diameter facility. Because of this non-uniformity, a CCFL is defined in the present work as the situation where net water accumulation is sustained. That is, some amount of water should not be allowed to penetrate the gap and accumulate over the gap at CCFL criterion. The measured data are presented in the form of Wallis'type correlation with characteristic length of gap size. It was found that the present correlation is in good agreement with other empirical correlation based on measurements whose test section diameter is close and the gap size is much larger than that of the present test section.