• Title/Summary/Keyword: witch

Search Result 141, Processing Time 0.043 seconds

The Influence of Magnetic Particle Size and Its Properties on The Electromagnetic Particle in Magnetic Tape (자기 Tape의 전자 변환 특성에 대한 자성분의 Size와 그 특성의 영향)

  • 김상문;김태옥
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.5
    • /
    • pp.334-339
    • /
    • 1996
  • In order to investigate the influence of the magnetic paticle size and its properties on the particulate magnetic material, we evaluated the dispersion of magnetic particles and the electromagnetic properties in magnetic tape made from the magnetic paints by use of each magnetic particles witch were different from particle size and its propertis. The dispersion of magnetic particles depends on the surface chemical properties rather than particle size. As particle size is smaller, the packing ratio of magnetic particle and the magnetic flux density in tape increase. The output levels in playing back of tape incerase in wide frequency range from 315 Hz to 10 kHz and the noises decrease. It is very important to choose the size, the shape, the surface chemical properties and the magnetic properties of the magnetic particle in producing the high quality magnetic tape.

  • PDF

An experimental investigation of thermodynamic performance of R-22 alternative blends (R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구)

  • Hwang, E.P.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF

A study on performance test of water heat storage type heat-pump system using cooling tower heat source (냉각탑을 이용한 축열식 히트펌프시스템의 성능측정에 관한 연구)

  • Lee, Sang-Hoon;Park, Hyo-Sik;Han, Woo-Yong;Kim, Uk-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1099-1104
    • /
    • 2008
  • Recent year, mean energy consumptions of a people are higher than other country. And international oil price became over 120 dollar. This energy environment as well as energy war. Maybe, the Meteorological Administration is going to enforce scorching heatwave special report system from that come summer. Besides, 2008 summer, maximum demand power is expected by 64,240,000kW. The electric power equipment reserve rate appeared in to keep 12.5% level. Chilled water storage system witch is one of electric load administration system. Heat pump system used cooling tower heat recovery is advantage that use is possible to summer in small a public bath building. In this paper, we suggest that heat pump system by heat recovery using cooling tower when it is heating operation of ambient air temperature. To apply cooling tower heat recovery heat pump to chilled water heat storage type and achieved performance evaluation about operation. As a result, performance of heat pump system that about 121% in cooling mode, 138% in heating mode higher than KEPCO standard. And heating operation possible to ambient air temperature about $23^{\circ}C$, which of appear cooling tower outlet temperature about $13^{\circ}C$.

  • PDF

A new analytical approach for optimization design of adhesively bonded single-lap joint

  • Elhannani, M.;Madani, K.;Mokhtari, M.;Touzain, S.;Feaugas, X.;Cohendoz, S.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.2
    • /
    • pp.313-326
    • /
    • 2016
  • In this study the three-dimensional nonlinear finite element method was used to analyze the stresses distribution in the adhesive layer used to joint two Aluminum 2024-T3 adherends. We consider in this study the effect of different parameters witch directly affect the values of different stresses. The experimental design method is used to investigate the effects of geometrical parameters of the single lap joint in order to achieve an optimization of the assembly with simple lap joint. As a result, it can be said that both the geometrical modifications of the adhesive and adherends edge have presented a significant effect at the overlap edge thereby causing a decrease in peel and shear stresses. In addition, an analytical model is also given to predict in a simple but effective way the joint strength and its dependence on the geometrical parameters. This approach can help the designers to improve the quality and the durability of the structural adhesive joints.

Information Resource Management (IRM) : Empirical Study in the Service Industry

  • Ha, Tae-Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.2
    • /
    • pp.14-22
    • /
    • 1999
  • The great flowing of information has brought a necessity for good management to make the best use of it in the highly competitive information age. The aims of this study are to investigate the main information sources - divided into largely three groups : literature sources, communication and information technology facilities,), trying to find problem areas associated with IRM, indicating possible solutions. The result shows that internal information sources were regarded the most important and most frequently used. For the use of foreign materials, the higher the level of position is, the more people use them. With respect to communication methods, internal information sources were thought most important. With the dramatic falling of the price despite enormously increased functions, IT facilities are becoming important sources. However, the study reveals the use of them is quite limited to a few well-known facilities, witch indicates that management should pay attention to more efficient use of them and useful training and education methods.

  • PDF

Estimation of the Sensor Location and the Step for Personal Navigation System (개인 항법 시스템을 위한 센서 위치와 보폭 추정 알고리즘)

  • Kim, Tae-Un;Lee, Ho-Won;Chwa, Dong-Kyoung;Hong, Suk-Kyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.2058-2065
    • /
    • 2010
  • This paper presents the sensor location and step estimation algorithm for personal navigation system (PNS). PNS has the disadvantage in that the position of the sensor must be fixed on a human body. Three-axis acceleration sensor is used to solve the disadvantage and to consider the real situation. We simplify the measurement data by using the band pass filter, witch It has the advantage in the detection of characteristic point. Through the detected characteristic points, it is possible to setup the parameter for the pattern detection. Depending on the sensor location, the parameters have the different type of noise covariance. Particularly, when the position of the sensor is changed, the impulse noise shows up. Considering the noise, we apply the recursive least square algorithm using the variable forgetting factors, which can classify the sensor location based on the estimated parameters. We performed the experiment for the verification of the proposed algorithm in the various environments. Through the experimental results, the effectiveness of the proposed method is verified.

A Study on the Stability of Torque for Compressing-Cutting Device of Nano Tube Manufacturing System Using DC Servo Motor (DC 서보모터를 이용한 나노튜브 제조용 압축-절단 장치의 토크 안전성에 관한 연구)

  • Choi, Kab-Yong;Oh, Tae-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5393-5397
    • /
    • 2011
  • The compressing-cutting device is used for manufacturing nano tube. the purpose of this study is to design and manufacture the compressing-cutting device witch has safety and stable performance. The most important core technology, in nano tube manufacturing, is to seam the each end of tube with appropriate pressure and to cut it off into the two part safely not to leak injected medium. Since the compressing pressure and the cutoff speed make the quality of nano tube, they are very important. This study will show the processes of design and manufacturing of compressing-cutting device.

Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

  • Tourab, Wafa;Babouri, Abdesselam
    • Safety and Health at Work
    • /
    • v.7 no.2
    • /
    • pp.102-110
    • /
    • 2016
  • Background: This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Methods: Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. Results: The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

Real operation of 2 kW class reverse-Brayton refrigeration system with using scroll compressor package

  • Kim, Hyobong;Yeom, Hankil;Choo, Sangyoon;Kim, Jongwoo;Park, Jiho;In, Sehwan;Hong, Yong-Ju;Park, Seong-Je;Ko, Junseok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.40-44
    • /
    • 2020
  • This paper describes the real operation of 2 kW class reverse-Brayton refrigeration system with neon as a working fluid. The refrigeration cycle is designed with operating pressure of 0.5 and 1.0 MPa at low and high pressure side, respectively. Compressor package consists of several helium scroll compressors witch are originally used for driving GM cryocooler. Three segments of plate heat exchanger are adopted to cover the wide temperature range and the refrigeration power is produced by turbo expander. The developed refrigeration system is successfully operated at its target temperature of 77 K. In experiments, all parameters such as pressure, temperature, mass flow rate and valve opening are measured to investigate characteristics during cool-down process and normal state. The difference between design and real operation is discussed with measured experimental data. At normal state of 77 K operation, the developed reverse-Brayton refrigeration system shows 1.83 kW at 68.2 K of cold-end temperature.

A Study on the Implementation of Digital Filters with Reduced Memory Space and Dual Impulse Response Types (기억용량 절약과 순회방식 선택이 가능한 디지털 필터의 구성에 관한 연구)

  • Park, In Jung;Rhee, Tae Won
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.6
    • /
    • pp.950-956
    • /
    • 1986
  • In this paper, a direct addressing mode of a microprocessor is introduced to save memory capacity, and also a dedicated digital filter is constructed to speed up the filter processing and to enable an easy selection of the impulse response types. A theoretical analysis has been conducted on the errors caused by the finite word klength, rounding-off and multiplication procedures. The digital filter designed by the proposed method is made into a module which can function as a 7th-order recursive or a 14-order nonrecursive type with a simples witch operation. The proposed filter is implemented on a printed-circuit board. The frequency characteristics of this filter can be controlled by the multiplication values stored in ROMs. A low-pass, a high-pass and a band-pass filter have been designed and their frequency characteristics are verified by actual measurements. For a order higher filer, two filter modules have been cascaded into an integrated filter of 23rd-order non-recursive low-pass type and a 12th-order recursive multiband type. Their frequency characteirstics have been found to agree with the theory.

  • PDF