• Title/Summary/Keyword: wire model

Search Result 655, Processing Time 0.027 seconds

Study on Enhancing Lightning Protection Scheme of Catenary in Subway Viaduct Section

  • Li, Rui-Fang;Chen, Kui;Chen, Li-Sheng;Cao, Xiao-Bin;Wu, Guang-Ning;Zhang, Xue-Qin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.950-958
    • /
    • 2017
  • Viaduct increases the height of subway catenary, namely magnifies lightning attraction scope that lead to higher possibility of suffering lightning stroke. Therefore, it is necessary to analyze performance of lightning striking to catenary of subway in viaduct section and propose an improving lightning protection scheme. In this paper, using ATP-EMTP simulation software to establish an associated model to evaluate lightning withstand level of catenary with existing lightning protection schemes including arrester and grounding point, an improving lightning protection scheme is proposed - every pillar ground earth and arresters are installed with some installing spacing between 200m to 400m based on lightning damage degree and reliability requirements - according to analyzing results: while lightning withstand level is lowest for lightning striking to the neutral pillar, lightning withstand level is greatest for lightning striking to the both-ends pillar that arrester and grounding point are both installed; grounding point could obviously improve lightning withstand level for lightning striking to ground wire while arrester could obviously improve the lightning withstand level for lightning striking to catenary; every pillar ground earth could enhance the lowest lightning withstanding level up to 2.5 times than of that pillar ground earth across every 200m.

Safety Evalution of on the cable of Extra dosed bridges by fire (화재에 대한 Extra-dosed교 케이블의 안전성 평가)

  • Rhu, Bong-Jo;Song, Young-Sun;Park, Weon-Tae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.23-33
    • /
    • 2008
  • Extra dosed bridge among the Cabled-stayed bridges have been increasingly built in korea in recently. But such bridges were often damaged by fire due to car collison. In this study Extra dosed bridges among the cabled-supported bridges are selected to analysis model frequently to be designed and/or constructed in recent and furture in this study. COSMOS FloWorks 2007 software are used for Heat Transfer Analysis and Thermal Stress Analysis. The safety of wire, HDPE pipe and stainless steel pipe are investigated. In the case of the constant of the temperature of the heat source, the significant three variables for the analysis are selected for study : (1) the distance between the fire-proof bulk head and the heat source, (2) wind velocity, (3) the height of the end of Stainless steel pipe.

Applying the Ferrocement Concept in Construction of Concrete Beams Incorporating Reinforced Mortar Permanent Forms

  • Fahmy, Ezzat H.;Shaheen, Yousry B.I.;Abdelnaby, Ahmed Mahdy;Abou Zeid, Mohamed N.
    • International Journal of Concrete Structures and Materials
    • /
    • v.8 no.1
    • /
    • pp.83-97
    • /
    • 2014
  • This paper presents the results of an investigation aimed at developing reinforced concrete beams consisting of precast permanent U-shaped reinforced mortar forms filled with different types of core materials to be used as a viable alternative to the conventional reinforced concrete beam. To accomplish this objective, an experimental program was conducted and theoretical model was adopted. The experimental program comprised casting and testing of thirty beams of total dimensions $300{\times}150{\times}2,000mm$ consisting of permanent precast U-shaped reinforced mortar forms of thickness 25 mm filled with the core material. Three additional typical reinforced concrete beams of the same total dimensions were also cast to serve as control specimens. Two types of single-layer and double-layers steel meshes were used to reinforce the permanent U-shaped forms; namely welded wire mesh and X8 expanded steel mesh. Three types of core materials were investigated: conventional concrete, autoclaved aerated lightweight concrete brick, and recycled concrete. Two types of shear connections between the precast permanent reinforced mortar form and the core material were investigated namely; adhesive bonding layer between the two surfaces, and mechanical shear connectors. The test specimens were tested as simple beams under three-point loadings on a span of 1,800 mm. The behavior of the beams incorporating the permanent forms was compared to that of the control beams. The experimental results showed that better crack resistance, high serviceability and ultimate loads, and good energy absorption could be achieved by using the proposed beams which verifies the validity of using the proposed system. The theoretical results compared well with the experimental ones.

The Comparative Study on Performance Analysis of Windows 7 and Ubuntu Applying Open Source IDS/IPS Suricata (오픈소스 IDS/IPS Suricata를 적용한 Windows7과 Ubuntu 성능 비교 분석)

  • Seok, Jinug;Kim, Jimyung;Choi, Moonseok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.141-151
    • /
    • 2017
  • Nowadays, It is undeniable that the threat of network security is growing as time flows due to worldwide development of wire/wireless, various Internet platform and sophisticated hacking techniques. The amount of traffics that Network security solution has to handle is increasing and recently many occurrence of explosive traffic attacks from PulseWave are being observed which has many similar characteristics to New DDos. Medium and small sized firms abroad have developed and distributed Snort and Suricata that are based on open-source Intrusion Detection System(IDS) / Intrusion Prevention System (IPS). The goal of this study is to compare between Windows7 by applying suicata 4.0.0 32bit version and Ubuntu 16.04.3 LTS by applying suicata 4.0.0 version which is an open source Intrusion Detection System / Intrusion Protection System that uses multi threads method. This experiment's environment was set as followed C1100 server model of Dell, Intel Xeon CPU L5520 2.27GHz*2 with 8 cores and 16 threads, 72GB of RAM, Samsung SSD 250GB*4 of HDD which was set on RAID0. According to the result, Suricata in Ubuntu is superior to Suricata in Windows7 in performance and this result indicates that Ubuntu's performance is far advanced than Windows7. This meaningful result is derived because Ubuntu that applied Suricata used multi core CPU and RAM more effectively.

A Study on the Computational Design of Static Mixer and Mixing Characteristics of Liquid Silicon Rubber using Fluidic Analysis for LED Encapsulation (LED Encapsulation을 위한 스태틱 믹서의 전산 설계 및 유동해석을 이용한 액상 실리콘의 혼합 특성에 대한 연구)

  • Cho, Yong-Kyu;Ha, Seok-Jae;Huxiao, Huxiao;Cho, Myeong-Woo;Choi, Jong Myeong;Hong, Seung-Min
    • Design & Manufacturing
    • /
    • v.7 no.1
    • /
    • pp.55-59
    • /
    • 2013
  • A Light Emitting Diode(LED) is a semiconductor device which converts electricity into light. LEDs are widely used in a field of illumination, LCD(Liquid Crystal Display) backlight, mobile signals because they have several merits, such as low power consumption, long lifetime, high brightness, fast response, environment friendly. In general, LEDs production does die bonding and wire bonding on board, and do silicon and phosphor dispensing to protect LED chip and improve brightness. Then lens molding process is performed using mixed liquid silicon rubber(LSR) by resin and hardener. A mixture of resin and hardener affect the optical characteristics of the LED lens. In this paper, computational design of static mixer was performed for mixing of liquid silicon. To evaluate characteristic of mixing efficiency, finite element model of static mixer was generated, and fluidic analysis was performed according to length of mixing element. Finally, optimal condition of length of mixing element was applied to static mixer from result of fluidic analysis.

  • PDF

A Real Scale Experimental Study for Evaluation of Permissible Shear Stresses on Vegetation Mats (식생매트 허용 소류력 평가를 위한 실규모 실험 연구)

  • Lee, Du Han;Kim, Dong-Hee;Kim, Myounghwan;Rhee, Dong Sop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6151-6158
    • /
    • 2012
  • By the activation of environment-friendly river works, application of vegetation mats is increasing, however, evaluation techniques for hydraulic stability of vegetation mats are not presented. This study is conducted to develop the objective test method for vegetation mats. Two kind of vegetation mats are tested by the real scale experiments, and hydraulic quantities are measured and analyzed to evaluate acting shear stresses. Roughness and shear stress are evaluated by 1 D non-uniform model. After each tests, changes in mat surfaces and sub-soil are evaluated, and from these evaluation, 3 types of mat surface damages and 2 types of sub-soil damages are presented. In the study, the case in which some damages in mat surface don't cause loss of sub-soil, is presented to be in the stable condition. Appling this stable condition and acting shear stresses, permissible shear stresses of vegetation mats are evaluated, and the results show that the reinforced mat with wire netting has more permissible shear stress.

A new precast wall connection subjected to monotonic loading

  • Vaghei, Ramin;Hejazi, Farzad;Taheri, Hafez;Jaafar, Mohd Saleh;Ali, Abang Abdullah Abang
    • Computers and Concrete
    • /
    • v.17 no.1
    • /
    • pp.1-27
    • /
    • 2016
  • Final construction project cost is significantly determined by construction rate. The Industrialized Building System (IBS) was promoted to enhance the importance of prefabrication technology rather than conventional methods in construction. Ensuring the stability of a building constructed by using IBS is a challenging issue. Accordingly, the connections in a prefabricated building have a basic, natural, and essential role in providing the best continuity among the members of the building. Deficiencies of conventional precast connections were observed when precast buildings experience a large induced load, such as earthquakes and other disasters. Thus, researchers aim to determine the behavior of precast concrete structure with a specific type of connection. To clarify this problem, this study investigates the capacity behavior of precast concrete panel connections for industrial buildings with a new type of precast wall-to-wall connection (i.e., U-shaped steel channel connection). This capacity behavior is compared with the capacity behavior of precast concrete panel connections for industrial buildings that used a common approach (i.e., loop connection), which is subjected to monotonic loading as in-plane and out-of-plane loading by developing a finite element model. The principal stress distribution, deformation of concrete panels and welded wire mesh (BRC) reinforcements, plastic strain trend in the concrete panels and connections, and crack propagations are investigated for the aforementioned connection. Pushover analysis revealed that loop connections have significant defects in terms of strength for in-plane and out-of-plane loads at three translational degrees of freedom compared with the U-shaped steel channel connection.

International Benchmarking of Land-to-mobile Interconnection Charges (국외 벤치마킹을 통한 이동망착신 접속료 수준 분석)

  • Kim, Tae-Sung;Jun, Hyo-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.360-370
    • /
    • 2013
  • As the mobile telecommunications service market grows rapidly, interconnection opportunities from the fixed network to the mobile network increase and the land-to-mobile (LM) interconnection charge becomes critical factor in competition between fixed and mobile telecommunications service providers. This paper aims to evaluate the LM interconnection charge level in Korea in comparison with those of 36 foreign countries and suggest the regression model for the LM interconnection charge. Based on the regression analysis, we found that regulation, GDP per capita, wire telephone penetration, liberalization are identified as significantly affecting factors on the LM interconnection charge level, and the level of the LM interconnection charge is comparatively low.

Uncertainty Assessment of a Towed Underwater Stereoscopic PIV System (예인수조용 스테레오스코픽 입자영상유속계 시스템의 불확실성 해석)

  • Seo, Jeonghwa;Seol, Dong Myung;Han, Bum Woo;Yoo, Geuksang;Lim, Tae Gu;Park, Seong Taek;Rhee, Shin Hyung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.4
    • /
    • pp.311-320
    • /
    • 2014
  • Test uncertainty of a towed underwater Stereoscopic Particle Image Velocimetry (SPIV) system was assessed in a towing tank. To estimate the systematic error and random error of mean velocity and turbulence properties measurement, velocity field of uniform flow was measured. Total uncertainty of the axial component of mean velocity was 1.45% of the uniform flow speed and total uncertainty of turbulence properties was 3.03%. Besides, variation of particle displacement was applied to identify the change of error distribution. In results for variation of particle displacement, the error rapidly increases with particle movement under one pixel. In addition, a nominal wake of a model ship was measured and compared with existing experimental data by five-hole Pitot tubes, Pitot-static tube, and hot wire anemometer. For mean velocity, small local vortex was identified with high spatial resolution of SPIV, but has serious disagreement in local maxima of turbulence properties due to limited sampling rate.

A Study of the Flame Transfer Function Characteristics using Cold-flow Transfer Function in a Partially Premixed Model Gas Turbine Combustor (부분 예혼합 가스터빈 연소기에서의 비연소 전달함수 계측으로부터의 화염전달함수 특성 파악)

  • Joo, Seongpil;Kim, Seongheon;Yoon, Jisu;Yoh, Jai-ick;Yoon, Youngbin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.5
    • /
    • pp.54-60
    • /
    • 2017
  • In order to identify the characteristics of the flame transfer function gain, cold-flow transfer function was introduced, which is the part of the combustion instability research. Nitrogen and carbon dioxide was used to obtain the cold-flow transfer function and input/output variables was measured by hot wire anemometry. Density and fluid flow rate affect the cold-flow transfer function gain and peak frequency. In addition, acoustic resonance frequency affects the peak frequency of gain in the fuel feeding line.