• 제목/요약/키워드: wire electrode

검색결과 224건 처리시간 0.025초

탄소섬유 시트 방전극의 입자 크기 별 집진 특성 및 공기청정기로의 응용 (Particle collection characteristics of carbon fiber sheet discharge electrode by particle size and application to air cleaner)

  • 신동호;우창규;홍기정;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제14권3호
    • /
    • pp.81-88
    • /
    • 2018
  • The market for improving the indoor air quality is continuously increasing, and air cleaners are the representative products. As interest in indoor air quality increases, so are the ultrafine particle which are harmful to the human body. Despite its many advantages, electrostatic precipitators are less used in indoor air due to ozone production. In this study, the carbon fiber sheet was applied to the discharge electrode and compared with the conventional tungsten wire discharge electrode. The particle collection efficiency and the amount of ozone generation were measured for 10-100 nm particles. Furthermore, it was applied to commercial air purifier with electrostatic precipitator to compare particle removal performance. The carbon fiber sheet type discharge electrode generates a small amount of ozone, and thus it can be applied to improve indoor air quality.

Effect of the Change in Electrode Construction for the Improvement of Ozone Characteristic of a Superposed Discharge Type Ozonizer

  • Rahman, Fayzur
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.17-22
    • /
    • 1999
  • In this paper a new discharge type ozonizer comprising the superpose operation of silent and surface discharge is presented. The ozonizer consists of two concentric glass tubes with three type of discharge electrodes : the external electrode(EE), the internal electrode(IE) and the central electrode(CE). By varying the structure of IE and materials of CE, we analyzed the characteristics of ozone related different parameters including $O_{3con}$, $O_{3g}$, and $O_{3Y}$. Using Cu made CE it was found the O3con is higher with Cu tape than that with Cu coil wound IE. At Q = 1[l/ min] the values of O3con were found as 3000[ppm] with Cu tape wound IE and 1898[ppm] with Cu coil wound IE. Then using SUS wire made CE with Cu tape wound IE at Q = 1[ι/ min] the maximum value of O3con was found as 5632[ppm]. It was observed that both $O_{3con}$ and $O_{3y}$ are higher with SUS made CE than that with Cu made CE. The maximum values of $O_{3Y}$ were found as 79[g/kWh] with Cu made CE and 170[g/kWh] with SUS wire made CE.

  • PDF

WEDG 전극가공에서의 전극표면형상의 실험적 고찰 (Experimental study on the surface integrity of electrode for WEDG process)

  • 안현민;김영태;박성준;이송규;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.218-222
    • /
    • 2002
  • Micro-EDM is generally used far machining micro holes, pockets, and 3-D structures. For micro-EDM, first of all, micro-electrode fabrication is needed and WEDC system is proposed for tool electrode fabrication method. When tool electrode is fabricated using WEDG system, its characteristics are under the control of many EDM parameters. Also relations between the parameters affect electrode fabrication. In this study, experiments are carried out to analyze effects of EDM parameters about electrode surface integrity on micro-electrode fabrication. Experimental method and analysis are used to experimental design method. Factors used in experiments are composed of capacitance, resistance, pause time, wire feed rate, spindle rotating speed. As a result of experiments, capacitance and resistance affect electrode surface.

  • PDF

방전 미세구멍가공 특성의 고찰 (A Study on the Micro Hole Machining Characteristics in WEDG method)

  • 정태현;박규율
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.953-956
    • /
    • 1997
  • Micro drilling characteristics by EDM method was investigated. In detail, Micro tool electrode for EDM drilling was machined by use of WEDG method and micro hole was drilled using the machined tool electrode in SUS plate. The machining accuracy and time was compared in a different dielectric fluid. As a result, it was convinced that this method could be utilized as a fabrication technology of micro mold or micro 3 dimensional parts.

  • PDF

대체 보조전극을 이용한 접지저항 측정값 비교 (Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode)

  • 이상익;유재근;전정채;전현재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

와이어컷 방전가공시 펄스변화에 따른 표면형상 특성 (Characteristics of Surface Morphology According to the Pulse Change When Wire-cut Electrical discharge Machining)

  • 이재명
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.537-542
    • /
    • 2000
  • Wire deflection, surface roughness and roundness were observed on changing discharge time for electrical discharge machining(EDM) of STD-11 in various conditions of thickness. The wire deflection was decreased as increasing discharge time and wire tension. The deflection is the smallest at the speed of wire of 10.6m/min and the water specific resistivity of 5k$\Omega$.cm. The deflection is found to be decreased as increasing dwell time. But if the water pressure is high, it is found not to be changed after the vibration of 4sec. The component of copper(Cu) and zinc(Zn), which is the main material of wire electrode, is observed for rough wire-cutting EDM of STD-11. This phenomena is found to be similar in spite of the change of EDM energy level. But it will be improved by changing the material and the shape of wire. The roundness of middle is found to be worse than that of upper and it is increased as the thickness of material is increased.

  • PDF

역전파 신경회로망을 이용한 가공조건에 따른 STD-11 절단면의 신뢰성 평가 (Reliability Evaluation of STD-11 Cutting Surface on the Machined Condition using the Back-Propagation Neural Network)

  • 김선진;성백섭;조규재;김하식;반제삼
    • 한국공작기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.7-15
    • /
    • 2004
  • The purpose of this study was to present the method to choose the optimum machining condition for the wire EDM. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. To measure the precision of the machining surface, average values are obtained from 3 samples of measures of center-line average roughness by using a third dimension gauge and a stylus surface roughness gauge.

NUMERICAL MODELING OF WIRE ELECTROHYDRODYNAMIC FLOW IN A WIRE-PLATE ESP

  • Chun, Young-Nam
    • Environmental Engineering Research
    • /
    • 제11권3호
    • /
    • pp.164-171
    • /
    • 2006
  • Numerical modeling of the flow velocity fields for the near corona wire electrohydrodynamic (EHD) flow was conducted. The steady, two-dimensional momentum equations have been computed for a wire-plate type electrostatic precipitator (ESP). The equations were solved in the conservative finite-difference form on a fine uniform rectilinear grid of sufficient resolution to accurately capture the momentum boundary layers. The numerical procedure for the differential equations was used by SIMPLEST algorithm. The Phoenics (Version 3.5.1) CFD code, coupled with Poisson's electric field, ion transport equations and the momentum equation with electric body force were used for the numerical simulation and the Chen-Kim ${\kappa}-{\varepsilon}$ turbulent model numerical results that an EHD secondary flow was clearly visible in the downstream regions of the corona wire despite the low Reynolds number for the electrode ($Re_{cw}=12.4$). Secondary flow vortices caused by the EHD increases with increasing discharge current or EHD number, hence pressure drop of ESP increases.

전극형 가습기의 특성을 개선하기 위한 실험적인 연구 (An Experimental Study to Improve the Characteristics of Electrode Type Humidifier)

  • 박규홍;송하진;변재영
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.310-315
    • /
    • 2009
  • This investigation was performed to study the characteristics of electricity and heat transfer that occur in the cylinder of electrode type humidifier during the process of water evaporation. Measurements were made to obtain the amount of water evaporation, the consumption of electric power, electrical conductivity, etc according to the materials and shapes of electrode. When the humidifier was in non-drain controlled mode, the number and amplitude of current cycle per minute increased gradually with the lapse of time, whereas for drain controlled mode, it decreased about 40[%] after draining water. It was found that for non-drain controlled mode, the thermal efficiency of humidifier which used SS400, STS316 and wire net electrode type was about 95~96[%] and it was 2~4[%] higher than that of drain controlled mode. Also, it was shown that the thermal efficiency of humidifier which used neighboring six-phase electrode balanced electrically was 4[%] higher than that of existing six-phase type.

Reference Electrode for Monitoring Cathodic Protection Potential

  • Panossian, Z.;Abud, S.E.
    • Corrosion Science and Technology
    • /
    • 제16권5호
    • /
    • pp.227-234
    • /
    • 2017
  • Reference electrodes are generally implemented for the purpose of monitoring the cathodic protection potentials of buried or immersed metallic structures. In the market, many types of reference electrodes are available for this purpose, such as saturated calomel, silver/silver chloride and copper/copper sulfate. These electrodes contain a porous ceramic junction plate situated in the cylindrical body bottom to permit ionic flux between the internal electrolyte (of the reference electrode) and the external electrolyte. In this work, the copper/copper sulfate reference electrode was modified by replacing the porous ceramic junction plate for a metallic platinum wire. The main purpose of this modification was to avoid the ion copper transport from coming from the inner reference electrode solution into the surrounding electrolyte, and to mitigate the copper plating on the coupon surfaces. Lab tests were performed in order to compare the performance of the two mentioned reference electrodes. We verified that the experimental errors associated with the measurements conducted with developed reference electrode would be negligible, as the platinum surface area exposed to the surrounding electrolyte and/or to the reference electrolyte are maintained as small as possible.