• 제목/요약/키워드: window energy

검색결과 693건 처리시간 0.022초

A new time-frequency analysis and structural instantaneous frequency extraction method based on modified spline-kernelled chirplet transform

  • Dong-Yan Xue;Ping-Ping Yuan;Zhou-Jie Zhao;Wei-Xin Ren
    • Smart Structures and Systems
    • /
    • 제33권6호
    • /
    • pp.385-398
    • /
    • 2024
  • To improve the accuracy of time-frequency analysis (TFA) and instantaneous frequency (IF) extraction of structural dynamic response signals, this paper improves the spline-kernelled chirplet transform, and a new form of modified spline-kernelled chirplet transform (MSCT) based on revised Gaussian window function and energy concentration principle is put forward. The effectiveness of the proposed method is verified by numerical examples of single-component signal, multicomponent signal, single-degree-of-freedom Duffing nonlinear system and two-layer shear frame structure model. Then, a time-varying cable test is designed to collect the acceleration response signals under linear changing tension, and the IF extraction of these signals is performed by using MSCT, which further verifies the effectiveness and accuracy of this method. Through numerical simulation and experimental verification, it is proved that the proposed method can effectively extract the IF of nonlinear structure and time-varying structure.

투과율에 따른 비정질실리콘 BIPV 시스템 효율 평가 (Performance Evaluation of a-Si BIPV System According to Transmittance Variation)

  • 차광석;이병두;김강석;신승철;이대우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.60.1-60.1
    • /
    • 2010
  • 공동주택에서 태양광발전(PV)을 통한 세대 전기에너지 이용은 모듈 설치 면적의 제약으로 인해 전 세대를 대상으로 활용하기에 현실적으로 어려움이 있다. 특히 남향이나 남동, 남서향으로 위치한 거실 창호를 활용하는 경우에도 결정질 실리콘(crystalline silicon) 태양전지 셀로 인한 실내 음영문제 등으로 건물통합형 태양광발전(BIPV) 시스템의 가시성을 확보하는데 한계가 있다. 따라서 이런 문제점을 극복하고자 투광형 비정질실리콘(amorphous silicon) 태양전지를 이용한 발코니창호/커튼월 BIPV 시스템을 구축하고, 테스트베드를 통한 적용성 평가 검증을 수행하였다. 테스트베드는 KCC 중앙연구소 1층 외부 측창에 결정질 BIPV 모듈(A2PEAK 사(社), 최대 출력 210 Wp, W 2,000 mm ${\times}$ H 1,066 mm)과 10% 및 30% 투광형 비정질 BIPV 모듈(Sharp 사(社) See Through type, 최대 출력 135 Wp/123 Wp, W 1,930 mm ${\times}$ H 1,180 mm)을 각각 설치(남서 $30^{\circ}$, 수직 $90^{\circ}$)하여, 2009년 5월에서 8월 사이 4개월에 걸친 모니터링을 통해 실제 발전량 데이터를 확보, 시스템에 대한 분석을 진행하였다. 분석 결과, 설치용량당 일평균 발전량은 결정질형이 1.46 kWh/kWp, 10% 투광형은 1.10 kWh/kWp, 30% 투광형은 0.73 kWh/kWp을 나타내었다. 10% 투광형과 30% 투광형의 모듈 성능 차이는 크지 않으나 발전량에 있어서는 큰 차이를 보였고, 10% 투광형의 설치용량당 일평균 발전량은 경정질형의 75.2% 수준으로 투광형 비정질실리콘 BIPV 시스템의 창호 적용 가능성을 확인하였다. 특히 세대 거실 창호를 통한 가시성 확보는 기존 결정질 BIPV 창호의 단점을 개선하였다. 건자재 일체화로 구축된 가시성확보 BIPV시스템 창호는 단위 세대별 적용이 쉽고, 공동주택에서 PV 시스템의 설치면적을 극대화시키므로 향후 Zero Energy 공동주택 구축에도 활용성이 클 것으로 기대된다.

  • PDF

ICCP를 사용한 전력센터간의 통신 프로토콜 구현 (Implementation of Communication Protocol between Control Centers using ICCP)

  • 장경수;장병욱;한경덕;신동렬
    • 한국정보처리학회논문지
    • /
    • 제7권12호
    • /
    • pp.3910-3922
    • /
    • 2000
  • 현재의 전력시스템은 컴퓨터와 통신기술의 발전으로 분산시스템인 EMS(Energy Menagement System)/SCADA(Super-vision Control and Data Acquisition) 형태로 운영되어 전력의 생산, 전송 그리고 분배가 효과적으로 이루어지고 있다. 그러나 각 시스템은 언어, 운영체제 그리고, 통신프로토콜이 서로 다른 제품으로 구성되어 시스템간에 데이터를 교환하는데 많은 어려움이 따르고 있다. 이러한 문제를 해결하기 위해서는 미국 전력연구소는 전력제어센터간의 통신을 담당하는 ICCP(Inter-Control Center Protocol)라는 새로운 형태의 통신규약을 발표하였다. ICCP는 자동화용 표준 통신규약인 MMS(Manufacturing Message Specification)를 응용계층의 하부 규약으로 지정함으로써 서로 다른 기종의 제어센터간의 원활한 통신을 지원한다. 본 논문은 ICCP의 특징과 MMS와 ICCP가 어떻게 상호 연관되는가를 밝힌다. ICCP에서 이용하는 MMS 라이브러리(library)의 86개의 서비스 중 일부 서비스를 구현한 후 이것을 이용하여 TCP/IP 환경 하에서 ICCP의 기본이면서 핵심적인 기능을 구현한다. 그 다음, ICCP 프로토콜을 이용하여 EMS간의 통신을 모델링하고, 전력센터간의 실제 데이터 교환을 윈도우 환경 하에서 구현하여 ICCP 프로토콜의 동작과 기능을 보여준다.

  • PDF

물 흡수선량 표준에 기반한 선량교정 프로그램 개발 (Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.175-183
    • /
    • 2003
  • 최근 선량측정의 정확성을 향상시키기 위하여 기존의 공기커마 교정인수에 기반한 표준측정법에서 물 흡수선량 교정인수에 기반한 표준측정법으로 변환하고 있는 추세이다. 본 연구에서는 미국의학물리학회의 AAPM TG-51과 국제원자력기구의 IAEA TRS-398 표준측정법에 대한 선량교정 프로그램을 개발하였다. 이 프로그램은 윈도우 환경에서 사용이 용이하도록 비쥬얼 C++언어를 사용하여 각각의 표준측정법에서 권고하고 있는 방법 및 절차에 따라 사용자의 편의성을 고려하여 개발하였다. 이 프로그램은 이온함에 대한 정보와 물리적인 자료에 대한 표와 그래프 값들을 수식화하여 데이터베이스화함으로써 수작업으로 인해 발생할 수 있는 실수 및 오차를 줄일 수 있다. 개발된 프로그램의 활용을 통하여 국내 실정에 적합한 물 흡수선량 표준에 기반한 표준측정법 개발에 토대를 마련하는데 있어 기여할 것으로 사료된다.

  • PDF

베네치안 블라인드 슬랫각도 형태변화에 따른 주광성능에 관한 연구 - Radiance Program 중심으로 (An Evaluating of Daylighting Performance by Venetian Blind Shapes Type Change - Centre on Radiance Program)

  • 임태섭;박종명;임정희;김병선
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.59-66
    • /
    • 2013
  • Current Architectural Facade Designs have been trending to increased glass areas resulting in increasing impact on interior lighting and daylighting. In regards to indoor environmental quality, the increase in window space has a large impact on the daylighting received which ultimately impacts the liveability of a space. Especially when considering seasons, in the summer, excessive daylighting can result in glare as well as put an increased load in conditioning the air space further reducing energy efficiency. As a result, in order to improve the sustainability performance of a building, it is important to limit the natural lighting exposure to properly meet the needs and conditions of the building occupants. One of the most representative features to limit excessive sunlight exposure, is to incorporate operable blind systems. To this end, this research has been based on simulations performance through the Radiance Program. Radiance is capable of analyzing performance of daylight and impact of sunlight. Through analysis of different slat angles and blind shapes, impact and minimization of energy usage was evaluated. Furthermore, seasonal analysis was performed in order to understand the effects of seasonal climate factors. Ultimately this research provides an analysis of operable blinds optimization and effects of blind shape, control factors and angle of shading.

공동주택의 그린 리모델링을 위한 외피시스템 환경영향 DB 구축에 관한 연구 (A Study on the Establish Environmental Impact of Database of the Envelope System for Green Remodeling of Apartment Housing)

  • 이종건;태성호;채창우;김낙현
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.73-79
    • /
    • 2016
  • Purpose: In order to improve the energy performance of existing buildings, so actively promoted green remodeling business. Also, improvement of the performance of envelope system of apartment housing is an absolute. The purpose of implementation of the data base and application plan of the envelope system for green remodeling of apartment housing. Method: For this study, It proposed a classification system of green remodeling envelope system constructed actual to select the applicable representative method and input material of apartment housing for green remodeling. In this study, divided into construction waste processing stage and production phase of the material for the boundary of the system, and implementation the classification system of the envelope system for applicable green remodeling. For this, established 6 environmental impact categories database. Result: As a result of various suggestions were available for case study research, alternative combinations of existing combinations than six kinds of environmental impact insulation system with superior input materials combining 96 kinds, window system, 12 kinds for determining the applicability of the established database. Depending on the account for a large proportion if compared to the detailed analysis of the environmental impact resulting from the production phase and disposal phase was analyzed that the operating management of the necessary input materials. Is considered that the economic performance and integrated energy performance required by the applicable public housing green remodeling evaluation techniques considered for future improvements insulation sheath.

폭발이 구조물에 미치는 영향 (Effects of Explosion on Structures)

  • 윤용균
    • 화약ㆍ발파
    • /
    • 제37권4호
    • /
    • pp.10-16
    • /
    • 2019
  • 충격파나 압력파가 구조물에 미치는 영향을 평가하기 위해서는 과압, 양의 압력 지속시간, 충격량에 대한 정보가 필요하다. 본 연구에서는 증기운 폭발 해석에 효과적인 다중에너지법을 적용하여 과압 및 양의 압력 지속 시간을 결정하였다. 영국 Nypro 화학회사에서 발생한 싸이클로헥산 증기운 폭발 사고에서 추정된 총 폭발열을 기반으로 폭발원으로부터 40, 80, 120, 160, 200, 240, 280, 320, 360(m) 이격된 지점에서의 과압, 양의 압력 지속시간을 평가하였다. 거리에 따라 과압은 지수적으로 감소하는 것으로 나타났고, 양의 압력 지속시간은 거의 선형적으로 증가하는 것으로 나타났다. 상기의 각 거리에서 구한 과압 및 충격량을 이용하여 각 거리에서의 구조물의 손상 확률을 평가하기 위해서 프로빗 함수를 사용하였다. 손상 확률을 평가한 결과 120m 이내 지점에서는 붕괴의 가능성이 크고, 240m 이내에서는 심각한 구조물의 손상이, 구조물의 가벼운 손상과 유리창 파손은 전 범위에 걸쳐서 발생하는 것으로 나타났다.

내측 블라인드의 하절기 일사열 차폐 성능 비교 (Comparing Solar Heat Shading Performances of Internal Blinds in the Summer)

  • 박은미;최동호;박민용;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.75-83
    • /
    • 2014
  • Heat loss through windows and doors occupies 20 to 45% of the total heat loss in building. It accounts for a large proportion of the total heat loss in building. In order to suppress the amount of heat flow through the windows and doors were considered actions such as reinforcement of insulation performance of window, adoption of low-e glass, and installation of solar heat shading device. The Purpose of this study is to compare solar heat shading performances of 3 types of internal blinds in the summer. In order to verify the solar heat shading performances of the blinds, a roll blind, blind A(Venetian blind) and blind B(Daylight guiding venetian blind)were installed in the four rooms with the same environmental conditions. As a result of the experiment, the blind B, blind A, roll blind showed an excellent performance in that order. Its because the blind B is made of aluminum materials coated with special paints on surface. It doesn't converted to long wave by short wave light. and it is reflected to short wave to outside.

$5kW_t$급 접시형 태양열 집열기의 설계 및 예비 성능실험 (Design and Preliminary Performance Test for 5kWt Dish Solar Collector)

  • 서주현;마대성;김용;서태범;한귀영
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.113-120
    • /
    • 2007
  • The 5kWt dish solar collector is designed and the preliminary performance test for this is carried out. The diameter of the parabolic dish is 3.2 m, and its focal length is 2 m. It consists of 10 small reflectors which have their own curvatures, and the effective reflecting area is $5.9\;m^2$, and the rim angle of the dish is $43.85^{\circ}$. The reflectivity of reflectors is 0.95, and the thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. A quartz window is installed at the receiver aperture to minimize the convective heat loss and prevent air leakage. In order to increase the heat transfer area, porous materials (nickel-alloy) are inserted into the receiver. Air flows into the upper part of the receiver which is the opposite side of the aperture. After the air flows through the inside of the receiver, that goes out of the receiver through 3 exits which are located near the aperture. The volumetric flow rates of air are varied from 600 to 1200 L/min. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases.

공동주택 단지 배치유형별 PV시스템 최적 설치면적 및 전기부하 기여율 평가 연구 (A Study on the Power Saving Fraction of Site Electrical Load depending on the installation area of PV system in Apartment Complex)

  • 윤종호;박재성;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.60-66
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex through the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performed with the hourly simulations of total received insolation on each surface considering the shading effect of buildings. Electrical load profile of typical Korean apartments were investigated for the load matching analysis. To calculate an annual total PV output, we used MERIT program which is a hourly based load matching tool developed by ESRD. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending on a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡtype revealed the best option for the maximum output of PV system.