• 제목/요약/키워드: window analysis

검색결과 1,519건 처리시간 0.032초

시뮬레이션에 의한 다기능 복합 솔라윈도우 시스템의 채광과 에너지성능평가 (The Daylight and Energy Performance Evaluation of Multi-purpose Solar Window System Using Simulaton Program)

  • 정열화;이순명
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.103-110
    • /
    • 2011
  • The aim of this study was to analysis the Heating/cooling performance and Daylighting performance of Solar Window System built in apartments. the solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system. The process of this study is as follows: 1)Solar Window system was designed through the investigation of previous paper and work. 2)The simulation program(Lightscape3.2) was used in daylighting performance analysis. the reference model of simulation was made up to analysis daylighting performance on Solar Window system. 3)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. the reference model of simulation was made up to analysis energy and daylighting performance on Solar Window system. 4)The Size of Simulation model for daylighting and heating/cooling energy analysis was $148.5m^2$ 5)The lighting performance analysis was carried out with various variants, such as the size and installed area of Solar Window system. 6)Energy performance simulation was carried out with various variants, such as Integrated U-value of Solar Window system according to its position, installed angle and insulation thickness. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down at the average of $4.1kWh/m^2$ or 4.2%.

다기능 복합 솔라윈도우 시스템의 에너지성능평가 (The Energy Performance Evaluation of Multi-purpose Solar Window System)

  • 조일식;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.10-15
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window System built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. The reference model of simulation was made up to analysis energy performance on Solar Window system. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

다기능 솔라윈도우의 열성능 연구 (The Study of Thermal Performance on Solar Window)

  • 조일식;김장회;양윤섭;김병수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in Heating/cooling performance analysis. The reference model of simulation was made up to analysis Heating/cooling performance on Solar Window. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

  • PDF

A Modeling Tool for X-Window Application Software Development

  • Lee, Joon-Seok;Lee, Sang-Bum;Chi, Dong-Hae
    • ETRI Journal
    • /
    • 제15권2호
    • /
    • pp.75-84
    • /
    • 1993
  • This paper presents a modeling tool, so-called X-ADD (X-window application Analysis & Design Diagram), which is useful for the understanding of existing X-window application program and the development of new X-window application software. This X-ADD tool is available for the X-window applications maintenance activities such as program understanding, and program analysis by the concept of reverse engineering. In addition, it supports the analysis and design for the new X-window application system development. Therefore, by the use of this tool, the visibility of the existing X-window application programs can be enhanced and modeling for the design of new X-window application systems can be easily made.

  • PDF

DEA-Window 분석 및 Malmquist 생산성지수를 사용한 우편집중국 효율성 및 생산성 변화 분석 (Analysis of Efficiency and Productivity Changes for Mail Centers Using DEA-Window Analysis and Malmquist Productivity Index)

  • 이재설;고현우
    • 산업경영시스템학회지
    • /
    • 제32권4호
    • /
    • pp.79-86
    • /
    • 2009
  • The purpose of this paper is to analyze the 24 mail center's efficiency and productivity changes from first quarter to fourth quarter of 2008 using window analysis and Malmquist productivity index. Row views of window analysis results make it possible to determine trends and/or observed behavior with the same data set, and column views to examine the stability of results across different data sets. Malmquist productivity indexes greater than unity translate into improvements in productivity, and less than unity mean deterioration in performance over time. The results of this study suggest that DEA models under dynamic situations such as window analysis and Malmquist productivity index enable us to comprehend the efficiency and productivity changes over time and to show the direction of improvements.

공기식 집열창 시스템이 설치된 건물의 동적부하 해석 (Time Dependent Thermal Load Analysis of the Building with an Airflow Window System)

  • 조성환;박상동
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.82-95
    • /
    • 1992
  • It has been known that the application of an airflow window system reduces the energy consumption compared with conventional double pane window in a building. But how to analyze thermal load in a building with an airflow window system has not been well known. so two kinds of method (Mode 1 and Mode 2) to analyze time dependent thermal load of the building with an airflow window system are presented in this study. The results of load analysis about the model building(total area : $4521m^2$, 3 floors) by Mode 2 show that the maximum cooling and heating load in a building with an airflow window system are decreased about 12-17% and about 19.5% than with double pane glass window, and yearly energy consumption with an airflow window system is saved about about 20% than with double pane glass window.

  • PDF

PVC 창호의 구성에 따른 단열성능 예측에 관한 연구 (Study on Estimate of Thermal Resistance of PVC Frame Window Due to Material Composition)

  • 성욱주;이진성;조수;장철용;백상훈;송규동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1075-1080
    • /
    • 2006
  • Purpose of this study is proposal of estimating method about window thermal performance that based on KS F 2278 'Test method of thermal resistance for windows and doors' due to material composition of PVC frame window. First step of this study is research of present state about material composition of PVC frame window. Second is selection of main effective elements about window thermal resistance. For example, composition of Glazing, Frame area ratio of total window area, frame width, opening type, area of heat transfer and so on. Third is multiple regression analysis about thermal performance of PVC frame window due to main effective elements. It produces equations of multiple regression analysis due to opening type. Case of sliding window is $Y=0.149+0.034X_g+0.248X_{far}$, 4track sliding is $Y=0.584+0.175X_g+1.355X_{far}-0.008X_{fw}$, Tilt & Turn window is $Y=-0.161+0.076X_g+0.576X_{far}+0.0008X_{fw}$.

  • PDF

EnergyPlus에 적용된 Simple Window Model의 한계와 개선에 관한 연구 (A Study on the Limitation and Improvement of Simple Window Model applied to EnergyPlus)

  • 김태호;고성호
    • 설비공학논문집
    • /
    • 제29권10호
    • /
    • pp.515-529
    • /
    • 2017
  • EnergyPlus, which is widely used in various fields, provides Simple Window Model, a window model that can be used practically. However, the results of building load using the model are different from those of the standard model. The main cause of the deviation by Simple Window Model was analyzed to be due to the assumption that all windows were considered as single layer. The purpose of this study is to propose a window model that improves the cause of deviation by Simple Window Model and can be easily calculated from the algebraic relations. The proposed window model solved the heat balance equation algebraically by using seven window characteristic coefficients. The coefficient relationships consisted of the heat transmission coefficient and solar heat gain coefficient as input parameters make practical use and calculation possible. As a result of comparing the deviation between each window model by implementing the dynamic analysis method, the proposed window model showed that the deviation of the total heating/cooling energy consumption was reduced to 1/3 compared to Simple Window Model for one year. Although the maximum energy consumption did not show any significant improvement, the indoor temperature evaluation showed significantly reduced deviation.

Acoustic Analysis with Moving Window in Normal and Pathologic Voices

  • Choi, Seong-Hee;Lee, Ji-Yeoun;Jiang, Jack J.
    • 말소리와 음성과학
    • /
    • 제2권3호
    • /
    • pp.165-170
    • /
    • 2010
  • In this study, the most stable portion was identified using 5% moving window during /a/ sustained phonation in normal and pathologic voice signals and the perturbation values were compared between normal and pathologic voices at the mid-point and at the most stable portion using moving window, respectively. The results revealed that some severe pathologic voice signals can be eligible for perturbation analysis by identifying the most stable portion with Err less than 10. In addition, the perturbation acoustic parameters did not differentiate the pathologic voice signals from the normal voice signals when the mid-point was selected to measure the perturbation analysis(p>0.05). However, significantly higher %shimmer and lower SNR values were observed in pathologic voices (p<0.05) when the most stable portion was selected by moving window. In conclusion, moving window could identify the most stable portion objectively which can allow toget the minimum perturbation values (%jitter, %shimmer) and maximum SNR values. Thus, moving window technique can be applicable for more reliable and accurate perturbation acoustic analysis.

  • PDF

Moving Window Principal Component Analysis for Detecting Positional Fluctuation of Spectral Changes

  • Ryu, Soo-Ryeon;Noda, Isao;Jung, Young-Mee
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권7호
    • /
    • pp.2332-2338
    • /
    • 2011
  • In this study, we proposed a new promising idea of utilizing moving window principal component analysis (MWPCA) as a sensitive diagnostic tool to detect the presence of peak position shift. In this approach, the moving window is constructed from a small data segment along the wavenumber axis. For each window bound by a narrow wavenumber region, separate PCA analysis was applied. Simulated spectra with complex spectral feature variations were analyzed to explore the possibility of MWPCA technique. This MWPCA-based detection of the peak shift, potentially coupled with 2D correlation analysis to provide additional verification, may offer an attractive solution.