• Title/Summary/Keyword: winding number

Search Result 194, Processing Time 0.032 seconds

Design of a Transverse Flux Linear Motor

  • Chang, Jung-Hwan;Kim, Ji-Won;Kang, Do-Hyun
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • This paper presents design procedures of a transverse flux linear motor (TFLM). The minimum and maximum flux linkage was determined by the simplified equivalent magnetic circuit and estimated average magnetic flux density at the air gap region by considering the shape of applied magnetomotive force (MMF). With this information, the number of turns of each phase winding was calculated based on the amplitude of applied voltage and speed of a mover. The rated current, coil diameter, and winding area were obtained with the aid of an empirical formula for determining the required MMF. The usefulness of the proposed design method for TFLM is verified by the three-dimensional equivalent magnetic circuit network (EMCN) method and the experimental results of prototyped machine.

Analysis of Eddy Current Loss on Permanent Magnets of Interior Permanent Magnet Synchronous Motor for Railway Transit (철도차량용 매입형 영구자석 동기전동기의 영구자석 와전류 손실 분석 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.370-375
    • /
    • 2012
  • In order to apply Interior Permanet Magnet Synchronous Motor(IPMSM) to the propulsion system of the railway transit, 110kW class IPMSMs with high-power density are designed as a concentrated winding model and a distributed winding model in this study. The concentrated winding model designed in this study is 6 poles/9 slots and the distributed winding model is 6 poles/36 slots. In general, the eddy current losses in the permanent magnets of IPMSM are caused by the slot harmonics. The thermal demagnetization of the magnet by the eddy current losses at high rotational speed often becomes one of the major problems in the IPMSM with a concentrated windings especially. A design to reduce eddy current losses in permanent magnet design is important in IPMSM for the railway vehicle propulsion system which requires high-speed operation. Therefore, a method to devide the permanent magnet is proposed to reduce the eddy current losses in permanent magnet in this study. Authors analyze the variation characteristics of the eddy current losses generated in permanent magnet of the concentrated winding model by changing the number of the division of the permanent magnets.

Characteristic Analysis on Teeth Parameter of Permanent Magnet DC Motor (영구자석 직류전동기의 회전자 치(齒) Parameter에 따른 특성해석)

  • Kim, Chul-Ho;Bae, Sang-Han;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.133-135
    • /
    • 1996
  • This paper deals with the effect of teeth number variation in permanent Magnet DC motor. As teeth number varies, both flux density distribution and winding pitch are influenced, which is closely related to torque-speed characteristics, output power, and efficiency. In this study, motor design carried out using finite element method, and prototype motors were manufactured to test their performance analysis. In spite of torque ripple due to cogging effect better characteristic of machine using small teeth number was recorded than the motors with large number of rotor teeth. One of that reasons is caused by adopting large coil-length due to large number of teeth, i. e. large coil-pitch.

  • PDF

Characteristics of SPMSM for electro-hydraulic actuator according to the slot number (직동력 고응답 엑츄에이터 구동용 표면부착형 영구자석형 동기 전동기의 슬롯 수에 따른 특성 연구)

  • Kwon, Soon-O;Lee, Byeong-Hwa;Lee, Jeong-Jong;Kim, Dae-Sung;Kim, Bum-Joong;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.824_825
    • /
    • 2009
  • This paper deals with the characteristics of SPMSM for hydraulic actuator according to the slot number. As a design variable, slot number affects the winding configuration and this leads to the total variation of motor characteristic. Therefore number of slot should be cautiously determined. Three SPMSMs are designed and THD of back emf, cogging torque, and torque ripple are compared. Among three SPMSMs, 36slots with 12 pole is chosen for further development considering motor characteristics and manufacturing.

  • PDF

A Study on the Design Parameters of the Static Ring in the Ultra-high Voltage Non-uniform Electric Field (초고압 불평등 전계에서 정전링 설계변수에 대한 연구)

  • Kim, Jin-Sung;Seo, Min-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.577-582
    • /
    • 2020
  • Electricity produced at power plants is distributed to consumers through several stages of substations. At this time, an ultra-high voltage transformer is needed in the initial transmission stage to transmit a voltage suitable for each consumer. A high voltage, non-uniform electric field is formed at the end of the winding of the ultra-high voltage transformer, which carries a risk of dielectric breakdown. The winding of the ultra-high voltage transformer is an electrode, which is the key to converting the magnitude of the voltage. A non-uniform electric field is formed along the shape of the winding end, resulting in high electrical stress. The static ring installed at the upper and lower ends of the winding is used to disperse the stress at the winding end. Several variables should be considered when designing a static ring. Among them, this study examined how the curvature of the static ring, the thickness of the insulating paper, the number of barriers, and barrier thickness affect the electrical stress of the static ring using the Finite Element Method. Suggestions to be considered when designing the static ring are proposed through the FEM results.

A Characteristic Analysis of SRM for vehicle with Different Phase Number (전동차용 SRM의 상수변화에 따른 특성 해석)

  • Choi Kyeong-Ho;Kim Kyeong-Sik;Chin yung-Churl
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.981-984
    • /
    • 2004
  • This paper presents the design results and characteristic analysis of SRM. For vehicle power supply for adaptable design of the SRM, variable design parameters, such as stator and rotor laminations, winding details, pole numbers, and pole arcs, phases numbers are required. So, in this paper the SRM design results and the comparison of characteristics for vehicle power supply as phases changed are described.

  • PDF

Operation Analysis of Novel UPFC without Series Injection Transformers (직렬주입변압기가 없는 새로운 UPFC의 동특성 분석)

  • 백승택;한병문
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.641-648
    • /
    • 2003
  • This paper proposes a novel UPFE based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC, assuming that the UPFC is connected with the 138-kV transmission line of one-machine-infinite-bus power system. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules.

Properties of the Detection Sensor of Magnetic Field for Distribution Line (배전 선로용 자계 검출 센서 특성)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.01a
    • /
    • pp.383-384
    • /
    • 2014
  • 본 논문에서 제시된 배전 선로용 자계 검출 센서는 비접촉형이며, 페라이트 코어로 구성되어 있다. 시편 코어의 권선수 및 길이의 변화에 따른 특성을 조사한 결과 탐색 코일의 권선수가 5,000턴이고 이격 거리가 6[cm] 이내에서 활선 여부를 검출할 수 있었으며, 전선과의 이격 거리에 대해서 자계의 세기가 제곱에 반비례로 감소하는 것을 확인할 수 있었다.

  • PDF

Operating Characteristics of Capacity Increase in a Flux-Lock Type Superconducting Fault Current Limiter (자속구속형 초전도 전류제한기의 용량증대를 위한 동작특성)

  • Nam, Gueng-Hyun;Choi, Hyo-Sang;Park, Hyoung-Min;Cho, Yong-Sun;Lee, Na-Young;Han, Tae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.200-202
    • /
    • 2006
  • We investigated the operating characteristics of a flux-lock type superconducting fault current limiters according to the number of the serial connection each the superconducting element at the additive polarity winding of a transformer. This SFCL consists of two coils wound in parallel on the same iron core, and the secondary coil is connected to the elements in series. Operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. It turns ratio between the primary and the secondary coils is 63:21. The analysis of voltage, current, and resistance in serial connection each element was performed to increase the applied voltage of flux-lock type SFCL. When the applied voltage was 200/$\sqrt{3}[V_{rms}]$ with three elements connected in seres, the peak value of the line current increased up to 26,24[A]. On the other hands, resistive SFCL increased up to 36.35[A], under the same conditions. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

  • PDF

Study of Shorted-turn for Cylindrical Synchronous Generator Rotor (원통형 동기발전기 회전자의 층간단락에 관한 연구)

  • Kim, Young-Jun;Kim, Jang-Mok;Lee, Sang-Hyuk;Ahn, Jin-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.52-56
    • /
    • 2006
  • This paper describes the methods for the detection of shorted-turn in the rotor of a cylindrical synchronous generator. A search coil is installed in the air-gap to detect the shorted-turn. The occurrence of a fault in the rotor winding results in a decrease of the induced voltages in the stator. And the magnitude of the rotor flux can be estimated by using the search coil and the estimated stator voltages respectively. And the magnitude of the estimated rotor flux is used for discriminating the rotor windings short or not by detecting the magnitude of the rotor flux. The method using a search coil located in the air-gap can detect not only the occurrence of a turn fault but also its position in the rotor winding. But the method using the estimated stator voltages gives the magnitude of the rotor flux, and only the number of a short-turn.