• 제목/요약/키워드: winding

검색결과 2,082건 처리시간 0.039초

실험을 통한 집중권선형 SynRM과 분포권 SynRM의 특성분석 (The Characteristic Analysis of Concentrated Winding Synchronous Reluctance Motor Vs. distributed Winding Synchronous Reluctance Motor through Experiments)

  • 이병두;이중호;이승철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1051-1052
    • /
    • 2011
  • This paper deals with optimum design criteria to minimize the torque ripple of a concentrated winding Synchronous Reluctance Motor(SynRM) using Response Surface Methodology(RSM). The feasibility of using RSM with the finite element method(FEM) in practical engineering problem is investigated with omputational examples and comparison between the fitted response and the results obtained from an analytical solution according to the design variables of stator and rotor in concentrated winding SynRM(6slot). The focus of this paper is the efficiency evaluation on the basis of load condition in a Concentrated Winding Synchronous Reluctance Motor and distributed Winding Synchronous Reluctance Motor.

  • PDF

차량 견인용 IPMSM의 집중권과 분포권 비교 (Comparison of Concentrated and Distributed Winding in an IPMSM for Vehicle Traction)

  • 오세영;임종빈;함상환;조수연;유광현;이호용;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.842-843
    • /
    • 2011
  • Winding methods of the interior permanent magnet synchronous motor for vehicle traction have two kinds. They are concentrated winding and distributed winding. They have merits and demerits and influence motor performance. Therefore, this paper present designs that concentrated winding and distributed winding motor what they have same capacity. And each motor characteristic was analyzed by finite element analysis.

  • PDF

MCSA를 이용한 BLDC 전동기의 고정자 권선 고장 진단 (Winding Fault Diagnosis for BLDC Motor using MCSA)

  • 이대성;양철오;김준영;김대홍;문용선;박규남;송명현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1876-1877
    • /
    • 2011
  • In this paper, a winding fault diagnosis method base on MCSA(Motor Current Signature Analysis) for BLDC motor is proposed. This method is programmed by LabVIEW for winding fault diagnosis. For winding fault diagnosis, two types of winding fault(shorted turn at one pole, shorted turn at two pole in same phase) are put intentionally in on phase. The motor current is collected by hole sensor, and transformed by the Park's transform, and then the Park's Vector Pattern are obtained, Usually this pattern is formed an ellipse, so a proper threshold value of distortion ratio(the ratio of the shortest axis and longest axis of ellipse) is suggested for winding faults diagnosis.

  • PDF

3권선 CCVT의 2차 전압 보상 방법 (Compensation of the secondary voltage of a three winding coupling capacitor voltage transformer)

  • 강용철;김연희;정태영;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.18-20
    • /
    • 2007
  • A coupling capacitor voltage transformer (CCVT) is used in an extra high voltage power system to obtain the standard low voltage signal for protection and measurement. To suppress the effects of ferro-resonance more effectively, a three winding CCVT is used. This paper proposes an algorithm for compensating the secondary voltage of the three winding CCVT. With the secondary voltage of the three winding CCVT, the secondary and tertiary currents are obtained; the primary winding current is obtained by considering non-linear characteristics of the core; the voltage across the capacitor and the inductor are calculated and then added to the measured voltage to compensate the secondary voltage. Test results indicate that the algorithm can reduce the errors of the three winding CCVT significantly.

  • PDF

가스터빈 발전기 회전자 권선의 절연상태 평가 (Assessment of Rotor Winding Insulation Condition for Gas Turbine Generators)

  • 김희동;김병래
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1818-1821
    • /
    • 2008
  • Several off-line diagnostic tests which include the insulation resistance(IR), polarization index(PI), low-voltage AC, and recurrent surge oscillograph(RSO) tests were performed to assess the condition of generator rotor windings. The low-voltage AC and the RSO tests were performed on the gas turbine generator rotor winding to detect shorted turns. Before intentionally applying artificial shorted faults, it was confirmed by the low voltage AC and the RSO tests that the winding was in sound condition. For simulated shorted rotor winding turns, the RSO test detected the fault in the winding. The RSO test was capable of identifying the number and pole location of the shorted turns for a number of simulated shorted coils.

2-Stage Commutated SRM with Auxiliary Winding for Reduction of Acoustic Noise

  • Jung, Tae-Uk
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.22-27
    • /
    • 2008
  • A new excitation strategy for a Switched Reluctance Motor with Auxiliary Winding(SRMAW) is described and tested. The proposed scheme has auxiliary winding with one diode which is wound over all poles in one winding. In this scheme, auxiliary winding is used to reduce magnetic stress during commutations. The abrupt change of a phase excitation produces mechanical stresses resulting in vibration and noise. The acoustic noise is reduced remarkably through the 2-stage commutation. The operational principle and a characteristic comparison of the conventional SRM show that this scheme has some advantages including noise reduction as well as high drive efficiency.

고주파 트랜스포머의 권선배열에 기법 따른 손실해석 (Power Loss Analysis according to Winding Array Method of High Frequency Transformer)

  • 윤신용;김일남
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.15-19
    • /
    • 2005
  • This paper analyzed the power loss characteristics according to winding thickness and winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM tool. The ferrite core model for analysis be used the EE10 type of TDK cop.. Transformer model objected flyback transformer type applied to flyback converter/inverter. Therefore, analysis results of loss were obtained from inner parameters of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

고압전동기 결함신호의 특징추출에 관한 연구 (Feature Extraction for Fault Signals of High Voltage Motor Stator Windings)

  • 박재준;김희동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1154-1157
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[KV]and 6.67[KV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF

필라멘트 와인딩 장력에 따른 Composite Bushing의 특성에 관한 연구 (Properties of Composite Bushing with Filament Winding Tension)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.34-34
    • /
    • 2010
  • This paper describes effect of the bending deformation of high voltage composite bushing with winding tension. The composite bushing can be formed, by adding silicone rubber sheds to a tube of composite materials. The FRP tube is internal insulating part of a composite bushing and is designed to ensure the mechanical characteristics. Generally the properties of FRP tube can be influenced by the winding angle, wall thickness and winding tension. As winding tension is increased glass contents was increased in the range of 70.4~76.6%. In the bending test, winding tension is increased residual deflection was decreased in the range of 14.0~12.2 mm.

  • PDF

Harmonic Winding Factors and MMF Analysis for Five-phase Fractional-slot Concentrated Winding PMSM

  • Kang, Huilin;Zhou, Libing;Wang, Jin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.20-26
    • /
    • 2014
  • To enhance torque density by harmonic current injection, optimal slot/pole combinations for five-phase permanent magnet synchronous motors (PMSM) with fractional-slot concentrated windings (FSCW) are chosen. The synchronous and the third harmonic winding factors are calculated for a series of slot/pole combinations. Two five-phase PMSM, with general FSCW (GFSCW) and modular stator FSCW (MFSCW), are analyzed and compared in detail, including the stator structures, star of slots diagrams, and MMF harmonic analysis based on the winding function theory. The analytical results are verified by finite element method, the torque characteristics and phase back-EMF are also taken into considerations. Results show that the MFSCW PMSM can produce higher average torque, while characterized by more MMF harmonic contents and larger ripple torque.