• Title/Summary/Keyword: wind turbines

Search Result 673, Processing Time 0.034 seconds

Gearless Doubly-fed Induction Generator for Wind Power Generation (풍력발전용 기어리스 이중여자 유도 발전기)

  • Park, Taesik;Moon, Chaejoo;Kim, Seonghwan
    • Journal of IKEEE
    • /
    • v.21 no.1
    • /
    • pp.81-84
    • /
    • 2017
  • As the demands for offshore wind power generation systems on a large scale have grown dramatically, and extensive developments in PMSG (Permanent Magnet Synchronous Generator) and DFIG (Doubly-fed Induction Generator) wind turbine system have been going on. However, the wind power systems have been more sophisticated, and their reliability becomes critical issues. Averagely, wind turbines have shut down for about a week per year for repairs and maintenance. Especially the high speed gearbox of DFIG is inevitable components for high power generation, but becomes one of the critical failures. In this paper, a new reliable gearless wind turbine structure is proposed. The gearless wind turbine can operate on a maximum power points by controlling the speed of a rotational stator. The proposed approach is verified by PSIM simulations, resulting in increased energy reliability.

Adaptive Control of Pitch Angle of Wind Turbine using a Novel Strategy for Management of Mechanical Energy Generated by Turbine in Different Wind Velocities

  • Hayatdavudi, Mahdi;Saeedimoghadam, Mojtaba;Nabavi, Seyed M.H.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.863-871
    • /
    • 2013
  • Control of pitch angle of turbine blades is among the controlling methods in the wind turbines; this measure is taken for managing mechanical power generated by wind turbine in different wind velocities. Taking into account the high significance of the power generated by wind turbine and due to the fact that better performance of pitch angle is followed by better quality of turbine-generated power, it is therefore crucially important to optimize the performance of this controller. In the current paper, a PI controller is primarily used to control the pitch angle, and then another controller is designed and replaces PI controller through applying a new strategy i.e. alternating two ADALINE neural networks. According to simulation results, performance of controlling system improves in terms of response speed, response ripple, and ultimately, steady tracing error. The highly significant feature of the proposed intelligent controller is the considerable stability against variations of wind velocity and system parameters.

The Steady-State Characteristic Analysis of 2MW PMSG based Direct-Drive Offshore Wind Turbine (2MW급 해상용 영구자석 직접 구동형 풍력 발전기의 정상상태 특성 해석)

  • Shin, Pyungho;Choi, Jungchul;Yoo, Chul;Kim, Daejin;Kyong, Namho;Ko, Heesang
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.9-16
    • /
    • 2015
  • In order to support various studies for assessment of onshore and offshore wind turbine system including foundations, the land-based version of 2MW PMSG direct drive wind turbine has been analyzed using HAWC2 that account for the coupled dynamics of the wind inflow, elasticity, and controls of the turbine. this work presents the steady-state response of the system and natural frequency of the first thirteen structure turbine modes as a function of wind speed. Rotor, generator speeds, pitch angle, power production, thrust force, deflections of tower and blade are compared for one case below and one case above the rated wind speed.

Structural design methodology for lightweight supporting structure of a multi-rotor wind turbine

  • Park, Hyeon Jin;Oh, Min Kyu;Park, Soonok;Yoo, Jeonghoon
    • Wind and Structures
    • /
    • v.34 no.3
    • /
    • pp.291-301
    • /
    • 2022
  • Although mostly used in wind turbine market, single rotor wind turbines have problems with transportation and installation costs due to their large size. In order to solve such problems, multi-rotor wind turbine is being proposed; however, light weight design of multi-rotor wind turbine is required considering the installation at offshore or deep sea. This study proposes the systematic design process of the multi-rotor wind turbine focused on its supporting structure with simultaneous consideration of static and dynamic behaviors in an ideal situation. 2D and successive 3D topology optimization process based on the density method were applied to minimize the compliance of supporting structure. To realize the conceptual design obtained by topology optimization for manufacturing feasibility, the derived 3D structure was modified to have shell structures and optimized again through parametric design using the design of experiments and the response surface method for detail design of their thicknesses and radii. The resultant structure was determined to satisfy the stress and the buckling load constraint as well as to minimize the weight and the resultant supporting structure were verified numerically.

Comparative Performance Evaluation of 10kV IGCTs in 3L ANPC and TNPC Converters in PMSG MV Wind Turbines (PMSG 풍력발전기용 3L ANPC와 TNPC 컨버터에서의 10kV IGCT 성능 비교 평가)

  • Lyngdoh, Amreena Lama;Suh, Yongsug;Park, Byoung-Gun;Kim, Jiwon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.6
    • /
    • pp.419-427
    • /
    • 2019
  • Several multilevel converter topologies have been proposed and compared. The three-level (3L) neutral-point-clamped (NPC) topology is promising and widely accepted. However, this topology suffers from uneven loss distribution among switches due to its fixed switching strategy. The 3L active NPC (ANPC) topology, which exhibits improved loss distribution profile, was proposed to address this disadvantage. The 3L T-NPC topology, a hybrid configuration of 2L and 3L NPC topologies, was introduced to address not only the loss distribution problem but also the reduction in the number of switches. In the present research, the application of these three topologies in PMSG-based medium-voltage wind turbines was investigated. The power devices considered were 10 kV IGCTs. Performance was evaluated in terms of a power loss of 10 kV IGCT for each NPC topology, which is a crucial indicator of thermal behavior, reliability, cost, and lifetime of any converter. The comparison was performed using ABB make 10 kV IGCT 5SHY17L9000 and the simulation tool PLECS.

Sliding-Mode Based Direct Power Control of a Doubly Fed Induction Generator for Wind Turbines (슬라이딩 모드 기반의 이중여자 유도형 풍력발전시스템의 직접전력제어기법)

  • Kim, Won-Sang;Sim, Gyung-Hun;Lee, Kyo-Beum;Jeong, Byoung-Chang;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.152-162
    • /
    • 2008
  • This paper presents a sliding mode controller (SMC) to directly control the active and reactive powers of a doubly ffd induction generator (DFIG) for wind turbines. Sliding-mode control (SMC) and space-vector modulation (SVM) are combined to ensure high-performance operation. SMC scheme is designed to provide robust and fast power controls without frame transformation and current controller used in the conventional FOC drive. Simulation results and experimental results demonstrate that proposed methods preserve the effectiveness and robustness during variations of active and reactive power.

Characteristics of Carburized Surface Layers in 0.18C-3.5Ni-1.5Cr-0.2Mo Steels for Main Shaft Bearings of Wind Turbines (풍력발전시스템의 주 베어링용 0.18C-3.5Ni-1.5Cr-0.2Mo강의 침탄 표면특성)

  • Choi, Byung-Young;Gub, Yoon-Sik
    • Journal of Surface Science and Engineering
    • /
    • v.45 no.6
    • /
    • pp.226-231
    • /
    • 2012
  • Characteristics of carburized surface layers in 0.18C-3.5Ni-1.5Cr-0.2Mo steels for main shaft bearings of wind turbines have been analyzed and evaluated before and after rolling contact fatigue tests. Mixed microstructure consisting of retained austenite and tempered martensite has been formed with compressive residual stresses in the surface hardened layers of the specimens showing uniform hardness distribution with value about Hv700 after vacuum carburizing and tempering. It has been found on the raceway of the layers of the specimens after rolling contact fatigue tests that the amount of retained austenite decreased and compressive residual stresses increased, resulting from cyclic contact stresses applied during the tests. It has been also revealed that higher durability of the bearings can be obtained through controlling the amount of the retained austenite in the surface of the bearing steels to be lower in this study.

Prediction of aerodynamics using VGG16 and U-Net (VGG16 과 U-Net 구조를 이용한 공력특성 예측)

  • Bo Ra, Kim;Seung Hun, Lee;Seung Hyun, Jang;Gwang Il, Hwang;Min, Yoon
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.109-116
    • /
    • 2022
  • The optimized design of airfoils is essential to increase the performance and efficiency of wind turbines. The aerodynamic characteristics of airfoils near the stall show large deviation from experiments and numerical simulations. Hence, it is needed to perform repetitive analysis of various shapes near the stall. To overcome this, the artificial intelligence is used and combined with numerical simulations. In this study, three types of airfoils are chosen, which are S809, S822 and SD7062 used in wind turbines. A convolutional neural network model is proposed in the combination of VGG16 and U-Net. Learning data are constructed by extracting pressure fields and aerodynamic characteristics through numerical analysis of 2D shape. Based on these data, the pressure field and lift coefficient of untrained airfoils are predicted. As a result, even in untrained airfoils, the pressure field is accurately predicted with an error of within 0.04%.

Assessment and Agricultural Use of Wind Resources in Southern Part of Gyeonygi Province (경기 남부지역 풍력자원의 평가와 농업분야 활용방안)

  • Hong, Seong-Gu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.3
    • /
    • pp.73-82
    • /
    • 2006
  • Wind energy is one of the promising renewable energies that could provide electricity and other mechanical power. Wind energy market is dramatically growing in many European countries, but wind power is only 0.2% of the total renewable energy uses that is only about 2% of the primary energy consumption in Korea. It is widely accepted that wind resources fur power generation are only limited in some areas including coastal regions and mountainous areas in Gangwon province in Korea, particularly in terms of large scale wind power developments. In this study, wind velocity data were analyzed with respect to the potential utilization. The data provided from National Weather Service were used for the analysis. In addition, field wind data were also collected and analyzed for the comparison between the national data. The comparison showed that there were significant differences between the experimental station and the national station that are about 5km away. Annual average wind speed at the experimental station was less than 2 m/s, which is not enough fur wind power generation. It seemed that the topographic condition resulted in a significant difference in wind speed. When 600 W and 2.5 kW wind turbines were used, annual power productions were only 186 kWh and 598 kWh, respectively. When the average wind speed is lower, wind pumping is an alternative use of wind. At the experimental station, the average pumping rate of $3m^3/h$ at the head of 3 m was expected at a 2.5 m rotor under the conditions that efficiencies of the rotor and the pump were 40% and 80%, respectively. It did not seem that the wind pumping was not applicable at the station either. A higher wind speed was required to install the wind machines. Meanwhile, wind pumping would be applicable in conditions with lower pumping heads. Other applications were introduced far further wind energy utilization, including wind powered ventilation and friction heat generation in greenhouses.

Comparative Analysis on the Design Conditions for Offshore Wind Power Structures in the Coastal Sea of Korea (한국 연안 해상풍력 구조물의 설계조건 비교분석)

  • Ko, Dong Hui;Jeong, Shin Taek;Cho, Hongyeon;Kang, Keum Seok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.1
    • /
    • pp.25-32
    • /
    • 2014
  • Offshore wind power structures are subject to coastal hydrodynamic loading such as wind and wave loads. A considerable number of turbines have been installed in Europe, but so far none in Korea. Interest in offshore wind energy is growing in Korea, and it is expected that projects will reach the design stage in the near future. This paper discusses the level of structural reliability implied by the design rules of ABS(2010, 2013) and IEC(2009). Metocean conditions in 4 Korean seas(Gunsan, HeMOSU 1, Mokpo, Jeju) were used in the calibrations to calculate the aerodynamic and hydrodynamic loads as well as the structural responses of the typical designs of offshore wind turbines. Due to the higher variability of the wind and wave climate in hurricane-prone areas, applying IEC strength design criteria in combination with Korea west sea conditions could result in a design with much lower reliability index than what is anticipated from a design in European waters. To achieve the same level of safety as those in European waters, application of ABS 100 year design standards are recommended. Level-1 reliability-based design suitable for the Korean sea state conditions should be introduced because the IEC standards does not consider the typhoon effects in depth and the ABS standards is a WSD design method. In addition, the design equation should be established based on the statistical characteristics of the wind and wave loads of the Korean sea areas.