• Title/Summary/Keyword: wind speed generator

Search Result 381, Processing Time 0.025 seconds

Computational Flow Analysis on Applicability of Vehicle-Induced Wind to Highway to Wind Power Generation (차량 유도풍 풍력발전 활용 가능성의 전산유동해석)

  • Kim, Hyun-Goo;Woo, Sang-Woo;Jang, Moon-Seok;Shin, Hyung-Ki
    • New & Renewable Energy
    • /
    • v.4 no.4
    • /
    • pp.30-36
    • /
    • 2008
  • The possibility of whether the induced wind from a vehicle traveling on highway can be used in wind power generation has been verified through computational flow analysis. The bus which is presumed to accompany relatively strong and wide range of induced wind compared to passenger vehicles because of its wide frontal area has been set as the subject of research. In order to ensure the reliability of research, the flow analysis surrounding the bus on a flat road where median strip is not installed has been compared with a preceding research while the validity of grid system and interpretation method used in this research have been assured by a qualitative method. In case of the median strip type wind power generator system, because it has been verified that a strong streamwise wind speed (5 m/s) is derived from the contraction effect of flow passage between the bus and the median strip while maintaining a relatively consistent upwind wind speed (1.4 m/s) in vertical direction in the wake area after the bus passes by although the change of wind speed is intense, it was decided as having some possibility of wind power generation. In case of the traffic sign panel type wind power generator system installed at the upper top of highway, because the wind speed of 2 m/s level has been derived for a limited time only at a section equal to the length of the bus and a faint induced wind speed less than 0.5 m/s was shown at other regions, it was decided as having almost no possibility of wind power generation.

  • PDF

Design of Speed Controller for Stall Blade Wind Turbine Complying with the Speed Limit During Speed Overshoot (속도 오버슈트 발생 시 제한 속도를 초과하지 않는 실속형 블레이드 풍력터빈의 속도제어기 설계)

  • Kim, Ye-Chan;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.438-445
    • /
    • 2022
  • Blade efficiency decreases when the rotor speed is kept constant even though the wind speed is higher than the rated value. Therefore, a speed controller is used to regulate the rotor speed in the high-wind-speed region. In stall-blade wind turbine, the role of the speed controller is important because precise aerodynamic regulation is unavailable. In this study, an effective parameter design method of a PI speed controller is proposed to limit the speed overshoot of a type 4 wind turbine with stall blades even though wind gust occurs. The proposed method considers the efficiency characteristics of the stall blade and the mechanical inertia of the wind turbine rotor. It determines the bandwidth of the speed controller to comply with the speed limit during generator speed overshoot for the worst case of wind gust. The proposed method is verified through intensive simulations with a MATLAB/SIMULINK model and experimental results obtained using a 3 kW MG set of wind turbine simulator.

The MPPT Control Method of the PMSG Wind Generation System using the Turbine Model with a Squirrel Cage Induction Motor (농형 유도기 터빈 모델을 이용해 구현한 영구자석 동기기 풍력발전 시스템의 MPPT 제어)

  • Lee, Joon-Min;Kim, Dong-Hwa;Shin, Hye-Su;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.231-236
    • /
    • 2012
  • This paper presents the MPPT(Maximum Power Point Tracking)control method of the PMSG wind generation system using the turbine model with a squirrel cage induction motor. The torque of squirrel cage induction turbine model is controlled by mathematization of speed characteristics of real blade. In this paper, maintenance and cost issues into consideration, except for previous method using information of the velocity of the wind speed sensor, the algorithm is presented. The algorithm is controlled by tracking the optimal point, the generator speed and maximum grid power. The vector controls of the generator side converter and the grid side converter are controlled respectively to obtain maximum torque and regulate unity power factor. With Psim simulations and experiments, the efficiency of squirrel cage induction turbine model and the validity of control algorithm are verified.

Active Use of DFIG-Based Variable-Speed Wind-Turbine for Voltage Control in Power System Operation

  • Ko, Hee-Sang;Yoon, Gi-Gab;Hong, Won-Pyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.254-262
    • /
    • 2008
  • This paper presents an active use of doubly-fed induction-generator(DFIG)-based variable-speed wind-turbine for voltage control in power system operation. For reasonable simulation studies, a detail dynamic model of a DFIG-based wind-turbine grid-connected system is presented. For the research objective, an innovative reactive power control scheme is proposed that manipulates dynamically the reactive power from the voltage source converter(VSC) with taking into account its operating state and limits.

The Comparison of Output Characteristic by the Electro-magnetic Structure Modification of the Axial Flux Type Permanent Magnet Synchronous Generator (종축 자속형 영구자석 동기 발전기의 전자기적 구조 변경에 따른 출력특성 비교)

  • Jung, Tae-Uk;Bae, Byung-Duk;Kim, Hoe-Cheon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.42-48
    • /
    • 2011
  • Generally, the structure without the stator core Axial Field Permanent Magnet (AFPM) generator was simple and there was nearly no cogging toque. And because it had the wide driving rate area, it had been being mainly used in the small wind power generation system. However, AFPM generator with non-slotted stator can't generate high voltage at low wind speed due to long air-gap. It is the reason of output efficiency drop. Therefore, in this paper, the AFPM synchronous generator with internal rotor and dual slotted stators for the small wind turbine is studied, and deal with a cogging torque minimization through the determination of optimum pole-arc ratio.

A Study of the Wind Turbine System by Variable Speed Hydraulic Torque Converter (가변속 유체토르크 컨버터를 이용한 풍력발전 시스템 연구)

  • Chong, Kyong-Won;Kim, Dong-Yong;Kim, Hee-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1114_1115
    • /
    • 2009
  • The wind most of the century, the average wind speed in the coast area 6m/s~8m/s operation as a large wind power generators is not enough to produce. But the generator of proposed wind turbine system is connected to Hydraulic torque converter is the actual development of this usage, the low investment and economic effects appear to be much lower there is. In case of the proposed wind turbine system, is possible to make torque transmission long distance, set up generator somewhere in between the tower or the ground as well as, nacelle weight can be greatly down.

  • PDF

Development of PSCAD Simulation Model for Doubly-fed Induction-type Wind Power Generation System (이중여자 유도형 풍력 발전기의 PSCAD 시뮬레이션 모델 개발)

  • Jeong, Byoung-Chang;Kim, Hee-Jung;Chung, Yong-Ho;Jeon, Young-Soo;Kwak, No-Hong;Song, Seung-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.261-264
    • /
    • 2006
  • In this paper, doubly-fed induction-type wind power generation system simulation model for grid connection is developed. The simulation model is based on PSCAD/EMTDC and consists of rotor-blade, blade controller, generator power converter and generator controller Blade controller controls the blade pitch angle for starting, peak power limiting and emergency condition. Generator controller controls the generator output power to maximize the system efficiency. Simulation results are shown for the variable wind speed conditions. The simulation model can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

  • PDF

Transient Simulation of a Self-Excited Induction Generator during Grid Faults

  • Kim, Chan-Ki;Choy, Young-Do;Lim, Seong-Joo
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • This paper deals with the transient performance of an induction generator in a wind power plant. An induction generator and grid equipment may be damaged when a sudden disturbance occurs, for example, a sudden disconnection from the utility grid. The reasons for this are over-voltage and over speed. This paper analyzes this phenomena using PSCAD/EMTDC and coincides with its corresponding mathematical equation.

The Steady-State Characteristic Analysis of 2MW PMSG based Direct-Drive Offshore Wind Turbine (2MW급 해상용 영구자석 직접 구동형 풍력 발전기의 정상상태 특성 해석)

  • Shin, Pyungho;Choi, Jungchul;Yoo, Chul;Kim, Daejin;Kyong, Namho;Ko, Heesang
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.9-16
    • /
    • 2015
  • In order to support various studies for assessment of onshore and offshore wind turbine system including foundations, the land-based version of 2MW PMSG direct drive wind turbine has been analyzed using HAWC2 that account for the coupled dynamics of the wind inflow, elasticity, and controls of the turbine. this work presents the steady-state response of the system and natural frequency of the first thirteen structure turbine modes as a function of wind speed. Rotor, generator speeds, pitch angle, power production, thrust force, deflections of tower and blade are compared for one case below and one case above the rated wind speed.

Flicker Measurement based on SVR for Fixed-Speed Wind Generator Systems

  • Van, Tan Luong;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.117-119
    • /
    • 2009
  • This paper presents a simulation model based on support vector regression (SVR) for flicker emission estimation from wind turbines. Training patterns are developed by varying the wind speed and network parameters that might affect the expected flicker levels. A comparison is done to the fixed speed wind turbine (WT), which leads to a conclusion that the factors mentioned above have different influences on flicker emission. The simulation results have shown that the flicker estimation is performed accurately.

  • PDF