• Title/Summary/Keyword: wind shielding effect

Search Result 21, Processing Time 0.235 seconds

Dynamic analysis of wind-vehicle-bridge system considering additional moments of non-uniform winds by wind shielding effect of multi-limb tower

  • Xu Han;Huoyue Xiang;Xuli Chen;Yongle Li
    • Wind and Structures
    • /
    • v.36 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • To evaluate the wind shielding effect of bridge towers with multiple limbs on high-speed trains, a wind tunnel test was conducted to investigate the aerodynamic characteristics of vehicles traversing multi-limb towers, which represented a combination of the steady aerodynamic coefficient of the vehicle-bridge system and wind environment around the tower. Subsequently, the analysis model of wind-vehicle-bridge (WVB) system considering the additional moments caused by lift and drag forces under nonuniform wind was proposed, and the reliability and accuracy of the proposed model of WVB system were verified using another model. Finally, the factors influencing the wind shielding effect of multi-limb towers were analyzed. The results indicate that the wind speed distributions along the span exhibit two sudden changes, and the wind speed generally decreases with increasing wind direction angle. The pitching and yawing accelerations of vehicles under nonuniform wind loads significantly increase due to the additional pitching and yawing moments. The sudden change values of the lateral and yawing accelerations caused by the wind shielding effect of multi-limb tower are 0.43 m/s2 and 0.11 rad/s2 within 0.4 s, respectively. The results indicate that the wind shielding effect of a multi-limb tower is the controlling factor in WVB systems.

Shielding effects on a tall building from a row of low and medium rise buildings

  • Zu, G.B.;Lam, K.M.
    • Wind and Structures
    • /
    • v.27 no.6
    • /
    • pp.439-449
    • /
    • 2018
  • Wind loading of a tall building built amidst a group of buildings in urban environment is always greatly affected by shielding effects. Wind tunnel tests were carried out to assess the shielding provided by a row of low-rise or medium-rise buildings upstream a square-section tall building of height-to-breadth ratio 6. Mean and dynamic wind loads on the tall building were measured at different wind incidence angles and presented as interference factors (IFs). It is found that presence of a row of upstream buildings provides significant shielding to the tall building. At normal wind incidence, the mean along-wind loads and all components of fluctuating wind loads on the tall building are always reduced by shielding. Vortex shedding seems to still occur on the upper exposed part of the tall building but the vortex excitation levels are largely reduced. The degree of shielding is found to depend on a number of arrangement parameters of the row of upstream buildings. Empirical equations are proposed to quantify the shielding effect based on the wind tunnel data.

The Study on Wind Shielding Effects According to Distance Between Two Ships (선박간 이격거리에 따른 WIND SHIELDING EFFECT 검토)

  • Koo, Myoung-Jun;Ha, Mun-Keun;Choi, Jae-Woong;Bae, Jun-Hong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1413-1417
    • /
    • 2004
  • The environmental elements which naturally occur can result in structural damages and operating faults of vessels under the navigation and mooring. These primary factors are considered as wind, waves and tide. In order to investigate wind shielding effects with respect to wind load conditions between two ships which face the wind directly or slantingly to the wind direction, this numerical simulation was preferred in terms of the variation of wind loads according to different distances, wind velocities and wind directions between two ships. The results were proved to be quite reasonable, comparing with experimental data from Danish Maritime Institute, and the report, "Environmental Conditions And Environmental Loads" published by Det Norske Veritas.

  • PDF

The effect of vegetation parameter characteristics of the multi-layer vegetation model on wind for numerical simulation of micro-meteorology (미기상 수치모의를 위한 다층식생모델의 식생 팍라메타가 바람에 미치는 영향)

  • 오은주;이화운;정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.6
    • /
    • pp.605-613
    • /
    • 2003
  • In order to make use of the protection effect against wind by the vegetation, it examined whether it should make what vegetation form and arrangement using the 2-dimensional non-hydrostatic model. When the foliage shielding factor increases, it becomes hard to take in protection effect against wind in a residential section. When it makes height of vegetation high, it becomes hard to take in protection effect against wind with height. In the comparison in the case where vegetation high is gradually made low toward wind-stream from a vegetation, and the case of making it low gradually, although former tends to receive the protection effect against wind by the vegetation, attenuation of wind velicity becomes large. In the comparison in the case where foliage shielding factor and distribution of density of leaf are gathered gradually toward wind-stream from a vegetation. It has been understood to evaluate to height the influence that the vegetation multi-layer model by which the heat revenue and expenditure in the direction of the vegetation height is considered is used, and to characterize the vegetation group by the parameter setting.

Measurement and Analysis of Radar Shielding and Doppler Effects by the Wind Farm (풍력발전단지에 의한 레이다 차폐 현상 및 도플러 측정 데이터 분석)

  • Kim, Min;Kang, Ki-Bong;Park, Sang-Hong;Jung, Joo-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.742-749
    • /
    • 2016
  • To cope with the rising cost of the fossil fuel and the need of renewable energy, many wind farms are being constructed along the coasts of Korean peninsula. However, construction of these wind farms may cause negative influences by the shielding effect and the Doppler frequency from the wind turbine on the military radars operated in the nearby region. Therefore, the analysis of electromagnetic phenomenon with the real wind turbine is required. This paper compare the measured electromagnetic shielding effect and Doppler effect with theoretical shielding effect according to obstacle in literature and the extracted Doppler frequency through signal modeling.

Dynamic analysis of coupled wind-train-bridge system considering tower shielding and triangular wind barriers

  • Zhang, Nan;Ge, Guanghui;Xia, He;Li, Xiaozhen
    • Wind and Structures
    • /
    • v.21 no.3
    • /
    • pp.311-329
    • /
    • 2015
  • A method for analyzing the coupled wind-vehicle-bridge system is proposed that also considers the shielding effect of the bridge tower with triangular wind barriers. The static wind load and the buffeting wind load for both the bridge and the vehicle are included. The shielding effects of the bridge tower and the triangular wind barriers are incorporated by taking the surface integral of the wind load. The inter-history iteration is adopted to solve the vehicle-bridge dynamic equations with time-varying external loads. The results show that after installing the triangular wind barriers in the area of the bridge tower, the bridge response and the vehicle safety factors change slightly. The peak value of the train car body acceleration is significantly reduced when the wind barrier size is increased.

Analysis of Different 500kV HVAC Transmission Lines Lightning Shielding

  • Nayel, Mohamed
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.4
    • /
    • pp.49-57
    • /
    • 2013
  • The lightning shielding of different 500 kV HVAC-TL high voltage AC transmission lines was analyzed. The studied transmission lines were horizontal flat single circuit and double circuit transmission lines. The lightning attractive areas were drawn around power conductors and shielding wires. To draw the attractive areas of the high voltage transmission lines, transmission line power conductors, shielding wires and lightning leader were modeled. Different parameters were considered such as lightningslope, ground slope and wind on lightning attractive areas. From the calculated results, the power conductors voltages affected on attractive areas around power conductors and shielding wires. For negative lightning leader, the attractive area around the transmission line power conductor increased around power conductors stressed by positives voltage and decreased around power conductors stressed by negative voltage. In spite of this, the attractivearea of the transmission line shielding wire increasedaround the shielding wire above the power conductor stressed by the positive voltage and decreased around the shielding wire above the power conductor stressed by negative voltage. The attractive areas around power conductors and shielding wires were affected by the surrounding conditions, such as lightning leader slope, ground slope. The AC voltage of the transmission lines made the shielding areas changing with time.

Numerical Study of Current and Wind Forces Acting on Two Floating Bodies in Tandem Configuration (직렬 배치된 두 부유체에 작용하는 조류력 및 풍력 특성에 관한 수치해석 연구)

  • Hong, Jang-Pyo;Nam, Bo Woo;Yoon, Kyoung-Won;Kim, Young-Sik;Sung, Hong-Gun
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.378-386
    • /
    • 2014
  • In this study, the characteristics of the current and wind forces acting on two floating bodies were numerically investigated using a commercial CFD software, STAR-CCM+. In the numerical analyses, LNGC was located right behind FSRU under uniform current or wind conditions. Steady calculations were carried out using a Reynolds averaged Navier-Stokes (RANS) solver and the realized k-epsilon model. First, the current coefficients of FSRU based only the CFD were compared with the model test data. Through this comparison, the present numerical models and mesh systems were indirectly verified. Next, computations for FSRU and LNGC in a uniform current were performed using different relative positions. It was found that the current coefficients were great affected by the longitudinal positions. Finally, the wind forces acting on FSRU and LNGC in tandem configurations were studied. The focus was on the shielding effects due to the aerodynamic interactions between FSRU and LNGC.

Wind tunnel test of wind loads and current loads acting on FLBT and LNG bunkering shuttles in side-by-side configuration and comparison with empirical formula (병렬 배치된 FLBT 및 LNG-BS에 작용하는 풍하중 및 조류하중에 대한 풍동 시험 및 경험식 비교 연구)

  • Park, Byeongwon;Jung, Jae-Hwan;Hwang, Sung-Chul;Cho, Seok-Kyu;Jung, Dongho;Sung, Hong Gun
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.266-273
    • /
    • 2017
  • In recent years, LNG bunkering terminals are needed to supply LNG as fuel to meet the emission requirements of the International Maritime Organization (IMO). A floating LNG bunkering terminal (FLBT) is one of the most cost-effective and environmentally friendly LNG bunkering systems for storing LNG and transferring it directly to an LNG fuel vessel. The FLBT maintains its position using mooring systems such as spread mooring and turret mooring. The loads on the vessel and mooring lines must be carefully determined to maintain their positions within the operable area. In this study, the wind loads acting in several side-by-side arrangements on the FLBT and LNG-BS were estimated using wind tunnel tests in the Force Technology, and the shielding effect due to the presence of ships upstream was evaluated. In addition, the empirical formulations proposed by Fujiwara et al. (2012) were used to estimate the wind force coefficients acting on the FLBT and those results were compared with experimental results.

Hemming Process Design of the Permalloy Shielding Can for the Stiffness and Shape Accuracy (퍼멀로이 실딩캔의 강성증대 및 형상 정밀도를 위한 최적 헤밍 공정설계)

  • Lee, Sun-Bong;Kim, Dong-Hwan;Kim, Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.5
    • /
    • pp.29-35
    • /
    • 2002
  • This study shows the process design and forming analysis of permalloy shielding can that support the automobile multi-display parts to indicate the accurate information of car. This study is particularly important, since the accuracy of permalloy shielding can is known to affect the magnetic properties such as coercivity and permeability quite sensitively. The objective functions are defects such as hemming wind, hemming length, hemming wrap and tightness in prehemming process. The pre-hemming angle is considered as design parameter. The commercial finite element program PAM-STAMP™ was used to simulate the pre-hemming and hemming process. The ANN (Artificial Neural Network) has been implemented for minimizing of objective function and for investigating effect of punch angle relevant to the pre-hemming process. The results of analysis to validate the proposed design method are presented.